The text of a manual · part 16 of 16
EasyCoder 501 XP Bar Code Label Printer Installation & Operation: Appendix 3: Communication Cables
Pages 107 to 109 of 109, from EasyCoder 501 XP Bar Code Label Printer Installation & Operation
The original document is the PDF (6.4 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Intermec 501 XP
Page 107
Appendix 3
Communication Cables Serial Interface
The EasyCoder 501 XP has – as standard – one serial communication interface: RS 232C on "uart1:". Protocol Default setup: Baudrate: 9600 Char. length 8 bits Parity: None Stop bits: 1 RTS/CTS Disabled ENQ/ACK: Disabled XON/XOFF: Disabled (both ways) New Line: CR/LF To change the serial interface settings, see chapter 7 “Setting Up the Printer”. Interface Cable Computer end: Printer end: Host Signal
DB9 or DB 25 female connector (PC) DB25 female connector EasyCoder 501 XP
DB-9 DB-25
RXD TXD CTS RTS
1 2 3 8 7
GND
5
DSR
6
1 2 3 4 5 6 7 16 20 22
Signal TXD RXD RTS CTS DSR Signal GND + 5V1 DTR RI
Host
DB-25 DB-25 1 2 3 4 5 6 7 16 20 22
Signal
1 3 2 5 4 20 7 shield RXD TXD CTS RTS DTR GND
6
DSR
1
/. The external +5V is limited to 200 mA and is automatically turned off at overload. It is intended to drive e.g. an external alphanumeric keyboard connected to the RS 232C port.
Intermec EasyCoder 501 XP – Installation & Operation Ed. 3
106
Page 108
Appendix 3
Parallel Interface
Communication Cables
The EasyCoder 501 XP has – as standard – one parallel Centronics communication port. Three different types of Centronics devices can be selected for this port in the compatible mode1 using the Intermec Fingerprint instruction SYSVAR(25), see Intermec Fingerprint 7.12 Reference Manual: Standard type Centronics Predefined timing for the ACK and BUSY signals when responding to host data is: 500 ns ACK, BUSY inactivated after ACK finishes. IBM/Epson type Centronics (default) Predefined timing for the ACK and BUSY signals when responding to host data is: 2500 ns ACK, BUSY inactivated as soon as ACK pulse starts. Classic type Centronics Predefined timing for the ACK and BUSY signals when responding to host data is: BUSY deactivated, wait 2500 ns, then give 2500 ns pulse on ACK. Select the desired device as standard IN channel by means of a SETSTDIO statement2. By default, "uart1:" is STD I/O. Interface Cable Connectors Computer end: Depends on type of host computer. Printer end: 36 pin female IEEE 1284B Centronics.
1
/. Nibble, byte, ECP and EPP are presently not supported. 2
/. Intermec Shell automatically sets the correct STD I/O when an application is selected, e.g. a Windows driver.
Intermec EasyCoder 501 XP – Installation & Operation Ed. 3
Pin 1 2–9 10 11 12 13 14 15 16–17 18 19–30 31 32 33-35 36
Signal DStrobe Data 0–7 Ack Busy PE Select AF GND GND Init Error GND Selectin
107
Page 109
Notes
Intermec EasyCoder 501 XP – Installation & Operation Ed. 3
108