Page 94
Chapter 13
Adjustments Printhead Pressure
The pressure of the thermal printhead against the ribbon or paper is factory adjusted. However, the use of thicker or thinner paper than normal could require the printhead pressure to be readjusted. Turn the adjustment knob clockwise for increased pressure, or counter-clockwise for less pressure. Print a few labels, preferably test labels (see chapter 7 “Setting Up the Printer”), and check the printout. Increased pressure generally gives a darker printout and vice versa. Repeat until the desired result is obtained. To find the basic setting, turn the knob counter-clockwise until there is no pressure left. Test with a piece of paper under the printhead – you should be able to pull it out without more than just a little resistance. Then turn the knob three to four (3–4) full turns clockwise. Fine-adjust using the trial-and-error method. NOTE! Do not use a higher printhead pressure than necessary, because it may increase the wear of the printhead and thus shorten its life.
Knob
Intermec EasyCoder 501 XP – Installation & Operation Ed. 3
93
Page 95
Chapter 13
Narrow Labels Adjustment
Adjustments
The printer is factory-adjusted for full size paper width. When using paper less than full width, it is recommended to adjust the printhead lift arm so it becomes centred on the paper. Thereby, an even pressure across the paper is obtained. A poorly adjusted lift arm may be detected by a weaker printout on the inner part of a less than full width paper. Similarly, when reverting to a wider paper, the arm should be adjusted, or the printout on the outer part of the paper could be weak. To adjust the printhead lift arm, proceed as follows: • Remove the ribbon, if any. • Loosen the knob that holds the lift arm. Move the arm inwards or outwards until the arrow on the tip of the arm becomes centrealigned with the paper web. While moving the arm, push at the part where the knob is situated, not at the tip. If the arm is hard to move, lift the printhead and pull the printhead bracket free from the magnet in the lift arm. • After having centred the arm, lock it by tightening the knob. • Reload the ribbon, if any.
Knob
Headlift Arm
Centre of paper
Intermec EasyCoder 501 XP – Installation & Operation Ed. 3
94
Page 96
Chapter 13
Label Stop Sensor Position
Adjustments
The label stop sensor (LSS) is a photoelectric sensor that controls the printer's paper feed by detecting gaps between labels, slots in paper strip, or black marks, depending on the printer's setup in regard of media type (see chapter 7 “Setting Up the Printer”). A prerequisite is obviously that the LSS is aligned with the slots or black marks. The label stop/black mark sensor (LSS) can be laterally adjusted within a range of 0 to 50 mm (1.96") from the inner edge of the paper by means of a screw accessible through the outer lower gable. Turning the screw clockwise will move the LSS inwards and vice versa. The position of the LSS in relation to the paper is best checked by looking head on into the print unit when the printhead is lifted. Align the centrepoint of the V-shaped upper sensor with the centre of the slots or marks to be detected. The linear markings on the lower guide plate can also be used for positioning of the LSS as they are spaced with an interval of exactly 1 cm (0.39") from the edge that guides the paper. This method is especially useful for black marks (measure the lateral position of the black marks with a ruler before loading the paper). If using irregularly shaped labels, align the LSS with the front tips of the labels
Upper part of LSS Detection Slot
OUT
IN
Adjustment Screw
Upper part of print unit removed to improve view.
Intermec EasyCoder 501 XP – Installation & Operation Ed. 3
95