EasyCoder 501 XP Bar Code Label Printer Installation & Operation: 9. Intermec Shell Startup Program

Pages 70 to 80 of 109, from EasyCoder 501 XP Bar Code Label Printer Installation & Operation

The original document is the PDF (6.4 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.

For the Intermec 501 XP

Page 70

Chapter 9

Intermec Shell Startup Program Introduction

Intermec Shell is a so called startup program (also called “autoexecfile”), i.e. a program that automatically starts running when the printer is turned on. Intermec Shell helps the operator to choose between a number of standard or custom-made application programs and to start certain useful facilities, as listed below. Application Programs • Intermec LabelShop (WYSIWYG label design program) • Intermec Windows Driver (for printing Windows programs) • Intermec Fingerprint (for creating your own programs) • Intermec Direct Protocol (easy-to-use slave protocol) • LINE_AXP.PRG (line analyzer program) • LSS-SENSOR.PRG (LSS troubleshooting program) • Other application programs in the printer's memory1 Other Facilities • Setup Mode • Print Setup • Testfeed • Test Label • Default setup • Update PC-card • Reboot

(manual setup from printer's keyboard) (printing setup on label) (formfeeds + auto-adjust of the LSS) (printing of test labels) (resetting all setup parameters to default) (downloading data from a computer to a PCcard inserted in the printer, or upgrading the printer's firmware from a PC-card) (restarting the printer)

Intermec Shell is factory-installed in the printer's permanent memory (device "rom:"). This implies that if you insert a memory card with another startup file before you turn on the printer, or if there is a startup file stored in the printer's permanent memory (device "c:"), this startup file will be used instead of Intermec Shell (see chapter 4;“Startup Files”).

1

/. A prerequisite is that the program is provided with the extension “.PRG”. However, some original Intermec utility programs are excluded: ERRHAND.PRG FILELIST.PRG MKAUTO.PRG

Intermec EasyCoder 501 XP – Installation & Operation Ed. 3

69

Page 71

Chapter 9

Starting Up with Intermec Shell

Intermec Shell Startup Program

A few seconds after you have turned on the power to the printer and the initialization is completed, the countdown menu of the Intermec Shell program will be displayed:

ENTER=SHELL 5 sec. v.4.2 Now you have 5 seconds to enter Intermec Shell by pressing the <Enter> key. Provided you have a working two-way communication with a terminal program in a host computer, you may – as an alternative – enter the Terminal Setup by transmitting “TTT” or “ttt” to the printer. The Terminal Setup is described later in this chapter. The lower line keeps you informed on how much time you have left. Should the time run out before you have taken any action to enter Intermec Shell, the last selected application in Intermec Shell will be opened. This implies that if you use the same application all the time, you will only need to turn on the power, once the application has been selected. If no other application has been selected yet, the default choice will be displayed when the countdown is completed, e.g.:

FINGERPRINT 7.12 This message means that you have entered the immediate mode of Intermec Fingerprint with "uart1:" (the standard RS 232C port) selected as std I/O channel (see Intermec Fingerprint manuals). If you want to enter another application, just restart the printer and enter Intermec Shell before the countdown is completed. If you enter the Intermec Shell from the countdown menus, the Select Application menu will be displayed:

SHELL SEL. APPLICATION In this menu, you can choose between three options: • Go to a stack of menus, where you can select an application program, by pressing <Enter>. • Go to the Facilities part of Intermec Shell by pressing <F5>. • Start the Terminal Setup program by transmitting “TTT” or “ttt” from the host.

Intermec EasyCoder 501 XP – Installation & Operation Ed. 3

70

Page 72

Chapter 9

Starting Up with Intermec Shell, cont'd.

Intermec Shell Startup Program

In Intermec Shell, the options are presented in stacks of menus, organized as infinite loops, where you can select the desired option, as illustrated by the diagram below. Select Application The Select application option allows you to enter a stack of menus showing the various application programs in the printer's memory. • Current appl. starts the last selected application (by default Intermec Fingerprint with "uart1:" selected as std I/O channel). • Intermec LabelShop sets up the printer1 for the various Intermec LabelShop label design programs for Microsoft Windows. This option requires that you also select a std IN/OUT channel, i.e. the channel you want to use for communication between the printer and the computer. Refer to the Intermec LabelShop manuals. • Intermec Windows Driver selects the parallel interface "centronics:" as standard IN/OUT channel and sets up the printer for the various Intermec Windows Drivers, which you can use on a personal computer to produce printouts from almost any program run under Microsoft Windows.

1

/. When the Intermec Labelshop application is started, the printer's communication setup is changed to the following values: Baudrate: 57600 Char. Length: 8 Parity: None Stopbits: 1 RTS/CTS: Enable ENQ/ACK: Disable XON/XOFF to host: Disable XON/XOFF from host: Disable New Line: CR/LF Receive buffer: 600 Transmit buffer: 600 If another application is selected later, these setup parameters will still be valid, unless the new application includes instructions to automatically change the setup. The setup could also be changed manully in the Setup Mode.

• Intermec Fingerprint is used to create, modify or run programs written in the Intermec Fingerprint programming language. This option requires that you also select a standard IN/OUT channel, i.e. the channel you want to use for communication between the printer and the computer (normally "uart1:"). For programming, do not use the parallel "centronics:" channel (one-way communication only). Refer to the Intermec Fingerprint manuals. • Intermec Direct Protocol is an easy-to-use printer protocol for down-loading label layouts and variable input data to a printer from a host computer. This option requires that you also select a standard IN/OUT channel, i.e. the channel you want to use for communi-cation between the printer and the host. Normally, select "uart1:". Refer to the Intermec Direct Protocol Programmer's Guide. • LINE-ALY.PRG (Line Analyzer) is a Fingerprint program that captures characters received by the printer on a communication channel and prints them on labels as described later in this chapter. • LSS-SENSOR.PRG is a program that facilitates troubleshooting of the label stop sensor. Refer to the Service Manual. • Other Application Programs If the printer contains any other application programs – standard or custom-made – these will presented as additional options.

Intermec EasyCoder 501 XP – Installation & Operation Ed. 3

71

Page 73

Chapter 9

Intermec Shell Startup Program

Starting Up with Intermec Shell,

Select Other Facilities As an alternative to selecting an application, you can step through a number of other useful facilities:

cont'd.

• Setup allows you to enter the Setup Mode to set up the printer by means of its built-in keyboard, see chapter 8 “Setup Mode”. • Print Setup allows you to produce a printout of the printer's current setup values (test label #5). • Testfeed allows you to feed out a number of label, ticket, tag or pieces of strip while the printer auto-adjusts its paper feed and label stop sensor or black mark sensor. It is recommended to perform a Testfeed operation each time you load a new roll of labels (or similar). • Test Label allows you to print a series of four test labels (test labels #1 – #4) in order to test the printout quality and printhead alignment. The labels are presented in an infinite loop, so you can print the series over and over again. Press <Enter> for each new label. • Default Setup allows you to reset all setup parameters to their respective default values, as listed in chapter 7. • Software Update is used for two purposes: - Update PC-card allows the printer to be used as a Flash PCcard programming device. By means of the Zmodem communication tool, files can be downloaded from a PC to a Flash PCcard1 inserted in the memory card slot in the printer's rear plate. Warning! If the Flash PC-card contains an earlier firmware version than the one in the printer, the printer's firmware will be downgraded without warning. - Update firmware is used to upgrade the printer's firmware from a new firmware version stored as a file in a PC. • Reboot has the same effect as turning off and on the power to the printer. To exit Intermec Shell without having selected any application program, use Reboot or restart the printer. Then wait for the 5 seconds countdown without taking any action, and the last selected application will be opened.

1

/. Only Flash PC-cards from Intermec and approved for the EasyCoder 501 XP/601 XP series can be used.

Intermec EasyCoder 501 XP – Installation & Operation Ed. 3

72

Page 74

Chapter 9

Intermec Shell Startup Program

Intermec Shell Diagram POWER ON

ENTER=SHELL 5 sec.

v.4.2 SHELL

SEL. APPLICATION

SEL. APPLICATION

CURRENT APPL.

ENTER=SHELL 4 sec.

Last selected application is started v.4.2 SEL. APPLICATION LABELSHOP

ENTER=SHELL 3 sec. v.4.2

SEL. APPLICATION

2 sec.

v.4.2 SEL. APPLICATION

STD I/O CHANNEL

Fingerprint 7.12

UART1

SEL. APPLICATION

STD I/O CHANNEL UART2

ENTER=SHELL 1 sec.

v.4.2 Direct Protocol

Last selected application is started Default: UBI Fingerprint w. std I/O = "uart1:"

See note 1 STD I/O CHANNEL CENTRONICS

SEL.APPL rom: LINE_AXP.PRG

SEL.APPL rom: LSS-SENSOR.PRG

Legend:

Note 1: This menu is only shown if an optional interface pcb is fitted

Return to previous menu. Proceed to next menu. Accept displayed option and proceed, or execute displayed option. Perform a Testfeed anywhere in Intermec Shell. Enter the Setup Mode from anywhere in Intermec Shell. Enter Terminal Setup by transmitting T T T or t t t to printer, when menus marked with a shade of grey are displayed!

The selected application is started

WINDOWS DRIVER ENTER=SHELL

SHELL SETUP

SETUP: SER-COM,UART1

SHELL PRINT SETUP

Prints a list of current setup values (test label #5).

SHELL TESTFEED

Performs a Testfeed, i.e. feeds out a number of blank copies while autoadjusting the label stop sensor.

SHELL TEST LABEL

Prints test labels #1 – #4 in a loop. Press Enter for each new label.

SHELL DEFAULT SETUP

ARE YOU SURE ? Y=ENTER/ N=F5

DEFAULT SETUP PERFORMED

SHELL SOFTWARE UPDATE

UPDATE: PC-CARD?

PC-CARD ERASE

See “Setup Mode”

TRANSFER FILE USING ZMODEM PROGRAMMING PC-CARD PROGRAMMING COMPLETED

UPDATE: FIRMWARE SHELL REBOOT

TRANSFER FILE USING ZMODEM

Printer rebooted automatically

Restarts the printer (same as power off/on)

Intermec EasyCoder 501 XP – Installation & Operation Ed. 3

73

Page 75

Chapter 9

Intermec Shell Startup Program

Terminal Setup Starting Terminal Setup

The Terminal Setup program in Intermec Shell allows the operator to control the whole Intermec Shell program remotely from a host computer or terminal and also to read or change the printer's setup. Obvious prerequisites are that there must be a working two-way (serial) communication between printer and host, and that the host runs a suitable communication program (e.g. MS Windows Terminal) that can transmit and receive data in ASCII format, i.e. as printable characters. Set up the terminal as VT100. You can enter Terminal Setup by transmitting three uppercase or lowercase T characters (TTT or ttt) while the printer either shows the Intermec Shell countdown menus or the Select Application menu.

Solving Communication Problems

1

/. By default, "uart1:" is standard IN/OUT channel and should be used for communication between printer and host, e.g. for running Terminal Setup or for programming. However, other ports could be appointed standard IN and/or OUT channel by means of the Intermec Fingerprint statement SETSTDIO. Refer to the Intermec Fingerprint manuals for further information.

If this does not work, the communication protocols of the printer and the host probably do not match, or there is some other communication error, e.g. a defect communication cable, wrong port selected on the host, or cable connected to some other port than "uart1:" on the printer1. You can check and change the printer's setup in the Setup Mode, which you can enter by pressing the <Setup> key on the printer's built-in keyboard. Proceed as described in chapter 8 “Setup Mode”. Among the facilities in Intermec Shell, you will also find a number of options that allow you to read or change the communication setup of the printer: • Setup This is another way of entering the Setup Mode, where you can browse through the setup parameters and make changes by means of the printer's keyboard. • Print Setup Here you can print the current setup on one or more labels. • Default Setup This option allows you to reset the communication parameters for all serial communication channels on the printer to default values. Change the communication setup of the printer according to the host or vice versa. Once printer and host has been set up with the same communication parameters, go to the “Select Application” menu and use the triple T (TTT or ttt) to start Terminal Setup.

Intermec EasyCoder 501 XP – Installation & Operation Ed. 3

74

Page 76

Chapter 9

Intermec Shell Startup Program

Terminal Setup, cont'd. Using Terminal Setup

The Terminal Setup program is self-instructing by means of prompts. You can move around in Intermec Shell in the same manner as when you control Intermec Shell manually by means of the printer's display and keyboard. The Setup part of Terminal Setup follows the same structure as setup files, see later in this chapter. Comprehensive explanations of the various setup parameters can be found in Chapter 7 “Setting Up the Printer”. When you transmit the triple T (TTT or ttt) to the printer, the following message will appear on printer's display:

SETUP FROM TERMINAL On the screen of the host, another message will appear: ----------------------------------------------Welcome to SHELL v.4.2 in terminal mode ----------------------------------------------Answer Y <CR> for Yes, <CR> for No. ---------------SHELL SEL. APPLICATION ---------------(Y / N / B): From here on, you can move around in Intermec Shell according to the diagram in the chapter “Using Intermec Shell” by answering Y (=Yes), N (=No), or B (=Back) to the prompts that successively appear on the screen. Note that the program also accepts the corresponding lowercase characters, e.g. y, n, and b.

Intermec EasyCoder 501 XP – Installation & Operation Ed. 3

75

Page 77

Chapter 9

Intermec Shell Startup Program

Terminal Setup, cont'd. Selecting an Application

This example shows how you for example can select the Intermec Fingerprint application: ---------------SHELL SEL. APPLICATION ---------------(Y / N / B):Y ---------------SEL. APPLICATION CURRENT APPL. ---------------(Y / N / B):N ---------------SEL. APPLICATION LABELSHOP ---------------(Y / N / B):N ---------------SEL. APPLICATION WINDOWS DRIVER ---------------(Y / N / B):N ---------------SEL. APPLICATION Fingerprint 7.12 ---------------(Y / N / B):Y ---------------STD I/O CHANNEL UART1 ---------------(Y / N / B):Y When you have answered the final prompt, the printer will start the selected application.

Intermec EasyCoder 501 XP – Installation & Operation Ed. 3

76

Page 78

Chapter 9

Intermec Shell Startup Program

Terminal Setup, cont'd. Changing the Setup

If you want to set up the printer or use any other of the facilities, you should answer N (=No) to the “Select Application” prompt. The following example illustrates how to enter the Setup Mode: ---------------SHELL SEL. APPLICATION ---------------(Y / N / B):N ---------------SHELL SETUP ---------------(Y / N / B):Y ---------------SETUP: SER-COM,UART1 From here you can navigate through the Setup Mode by means of keys on a VT100 terminal according to the same principles as when using the printer's own keyboard (see overviews in chapter 8): Key u d e b f x 0–9 . Enter Backspace

Action Move one menu to the left on the same level (same as <F1>). Move one menu to the right on the same level (same as <F2>). Display error message at test label printing failure (same as <F3>). Move up one level or scroll back in a stack of menus (same as <F4>). Move down one level or scroll forward in a stack of options (same as <F5>). Exit the setup (same as <Setup>). Enter numeric values. Specify negative values (same as < . >). Acknowledge and move to next menu, perform testfeeds, or print test labels (same as <Enter>). Delete one character to the left of the cursor (same as <C>).

Intermec EasyCoder 501 XP – Installation & Operation Ed. 3

77

Page 79

Chapter 9

Intermec Shell Startup Program

Terminal Setup, cont'd. Exiting Terminal Setup

To exit the Terminal Setup program, e.g. after having changed the setup, you must select the Reboot option after having stepped through all the facility options, as illustrated below: ---------------SHELL PRINT SETUP ---------------(Y / N / B):N ---------------SHELL TESTFEED ---------------(Y / N / B):N ---------------SHELL TEST LABEL ---------------(Y / N / B):N ---------------SHELL DEFAULT SETUP ---------------(Y / N / B):N ---------------SHELL SOFTWARE UPDATE ---------------(Y / N / B):N ---------------SHELL REBOOT ---------------(Y / N / B):Y

Intermec EasyCoder 501 XP – Installation & Operation Ed. 3

78

Page 80

Chapter 9

Line Analyzer

Intermec Shell Startup Program

The Line Analyzer (LINE_AXP.PRG) is a program written in the Intermec Fingerprint programming language and intended to help solving possible communication problems. As the name implies, the Line Analyzer captures all incoming characters on a specified communication channel and prints them on one or several labels. Printable characters are printed in black-on-white, whereas control characters and space characters (ASCII 00–32 dec) are printed in white on a black background. While the printer is receiving data, the “Ready” control lamp blinks. There is a 0.5 sec timeout. If no more character has been received after 0.5 seconds, the program considers the transmission terminated and prints out a label. As long as a continuous string of characters is being received, the program wraps the lines until the label is full and then starts to print another label. At the bottom of each label, the following information is printed: • Page number • Number of characters printed on the label • Total of characters received so far The Line Analyzer is displayed as the option “LINE_ALY.PRG" under the “SEL. APPLICATION” menu. After the Line Analyzer has been selected and the printer has started up again, the printer feeds out two labels and the following menu is displayed:

Line Analyzer Sel.port(1-4) 1 Enter the desired communication port by means of the numeric keys on the printer's keyboard: 1 = "uart1:" 2 = "uart2:" 4 = "centronics:" If the printer is not fitted with the specified port, an error message appears in the display and you can select another port:

Line Analyzer Error:56

Intermec EasyCoder 501 XP – Installation & Operation Ed. 3

79