The text of a manual · part 22 of 26
TRAKKER Antares 248X Stationary Terminal User's Manual, pages 211 to 220
Pages 211 to 220 of 255
The original document is the PDF (2.2 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Intermec 2480, Intermec 2481 and Intermec 2485
Page 211
A Terminal Specifications
Page 212
Page 213
nugget
39 Terminal Specifications
A
This appendix lists the terminal’s physical and environmental specifications, lists the default configuration, and provides a configuration command reference list in alphabetical order by command syntax.
Physical and Environmental Specifications You can use the tables in this section to find technical information about these features and options: •
Terminal Dimensions
•
Power Specifications
•
Electrical Specifications
•
Temperature and Environmental Specifications
•
Screen
•
Keypad Options
•
Application Options
•
Memory
•
RF Communications
•
RF Network Support Options
•
Wired Data Communications
•
Bar Code Symbologies
•
Input Devices for the External Scanner Port
Note: For programming and file system specifications, see Chapter 5, “Using Custom Applications and Screen Mapping.”
A-3
Page 214
TRAKKER Antares 248X Stationary Terminal User’s Manual nugget 39
Specifications Terminal Dimensions Length:
10.7 in (27.2 cm) 11.3 in (28.7 cm) with a badge scanner installed
Height:
9.6 in (24.4 cm)
Depth:
3.9 in (9.9 cm)
Weight:
9.5 lbs (4.3 kg)
Power Specifications Operating (with power supply):
95 to 250 VAC, 50 to 60 Hz, 125 mA
Memory Backup:
Rechargeable NiCd 700 mA battery pack
Electrical Specifications Models: Electrical rating:
T2480, T2481, T2485, and T2486
S 12V, 750 mA
Temperature and Environmental Specifications Operating the terminal:
-4°F to +122°F
-20°C to +50°C
Storing the terminal:
-4°F to +140°F
-20°C to +60°C
Charging the backup battery:
+32°F to +104°F
0°C to +40°C
Relative humidity:
0 to 95% non-condensing
Screen •
CGA-compatible, backlit LCD
•
4 lines by 40 characters for T2480 and T2485
•
12 lines by 40 characters for T2481 and T2486, display up to 25 lines
Keypad Options •
Alphanumeric keypad with 59 keys, 5 separate function keys, PC-style layout, available in English, French, German, Italian, Portuguese, or Spanish
•
Oversized function numeric keypad with 35 keys, 10 separate function keys
•
Terminal emulation keypads for IBM 3270, IBM 5250, and VT/ANSI
•
Time and attendance keypad
Note: See your Intermec sales representative for information about the availability of the time and attendance keypad.
A-4
Page 215
nugget
39 Terminal Specifications
A
Application Options •
Programmable terminal
•
IBM 3270 terminal emulation
•
IBM 5250 terminal emulation
•
VT100/220/320 and ANSI terminal emulation
•
Screen mapping for 3270, 5250, or VT/ANSI (UDP Plus terminals only)
Memory •
2MB programmable flash memory, 750K available for use
•
1MB battery-backed RAM, 512K available for user
•
Extended memory option for an additional 2MB flash
•
Extended memory option for an additional 2MB or 4MB SRAM storage drive
RF Communications •
2.4 GHz (to 2.4835 GHz) radio (frequency range varies by country)
•
WLI Forum OpenAir™ compatible frequency hopping spread spectrum radio
•
100 mW maximum output power
•
1.6 Mbits per second data speed, 800 Kbps fallback rate for extended range
•
Coverage ≥ 240 feet (80 meters)
•
RF network protocol options: TCP/IP or UDP Plus
RF Network Support Options •
Connectivity to a host on an Ethernet, token ring, twinaxial, coaxial, or SDLC network through an access point and Model 200 Controller using UDP Plus protocol
•
Connectivity to a host on an Ethernet or token ring network through an access point using TCP/IP protocol
Wired Data Communications •
RS-232C serial port (COM1)
•
RS-232C/422/485 serial port (COM2) with enhanced input/output board
•
RS-232C serial port (COM4) with adapter cable accessory (Part No. 067185)
•
Ethernet (10BaseT)
•
Ethernet network protocol options: TCP/IP or UDP Plus
•
XMODEM/YMODEM protocol for data transfer
•
Protocols: Configurable Serial Protocol, Multi-Drop, Polling Mode D, Master Polling, Binary
A-5
Page 216
TRAKKER Antares 248X Stationary Terminal User’s Manual nugget 39 Bar Code Symbologies •
Codabar
•
Code 93
•
Code One
•
Code 128
•
Code 11
•
Interleaved 2 of 5
•
Code 16K
•
MSI
•
Code 2 of 5
•
PDF 417
•
Code 39
•
Plessey
•
Code 49
•
UPC/EAN
Input Devices for the External Scanner Port You can attach these input devices to the external scanner connector: •
Intermec 1354 and 1355 badge scanners
•
Intermec 1463A and 1463D CCD scanners
•
Intermec 1516A, 1517A, 1517B, 1518, and 1519A laser scanners
•
Intermec 1545 laser scanner
•
Intermec 1550A laser scanner
•
Intermec 126X, 127X, and 128X wands
You must use an interface cable to connect the input device to the scanner connector. For help, contact your local Intermec service representative.
Note: If you do not have a device installed on the badge scanner connector, you can use the Intermec 1464 CCD scanner, the Intermec 1550B laser scanner, and the Intermec 1551 laser scanner. To use the 1463A and 1463D CCD scanners together with a device installed on the badge scanner connector, you must configure the 1463A or 1463D Trigger mode to either Manual Trigger or Auto-Trigger.
A-6
Page 217
nugget
39 Terminal Specifications
A
Default Configuration The next tables show the terminal’s default configuration. You can use the TRAKKER Antares 2400 Menu System to set the terminal to the default configuration. For help, see “Restoring the Terminal’s Default Configuration” in Chapter 3.
Default Configuration for Bar Code Symbologies Parameter
Default
Codabar
Disabled
Code 11
Disabled
Code 16K
Disabled
Code 2 of 5
Disabled
Code 39
Full ASCII Code 39 enabled with no check digit
Code 49
Disabled
Code 93
Disabled
Code 128
Standard
Interleaved 2 of 5
Disabled
MSI
Disabled
Plessey
Disabled
UPC/EAN
UPC-A/EAN-13 enabled, UPC-E and EAN-8 enabled, supplementals allowed, transmit check digit, transmit number system digit, and retain leading zero for UPC-A
A-7
Page 218
TRAKKER Antares 248X Stationary Terminal User’s Manual nugget 39
Default Configuration for Operations
A-8
Parameter
Default
Append Time
Disabled
Automatic Shutoff
0 minutes (disabled)
Beep Volume
Normal
Command Processing
All reader commands enabled
Decode Security
Moderate
Display Contrast
3 (maximum contrast)
Display Font Type
8x16 font
Display Row Spacing
0 (T2481 and T2486 only)
Display Video Mode
Original
Keypad Caps Lock
Caps lock off
Keypad Clicker
Enabled
Keypad Type
Hardware default
Postamble
No characters (disabled)
Preamble
No characters (disabled)
RAM Drive Size
0 (no RAM drive)
Resume Execution
Allowed
Scan Ahead
Disabled
Scanner Mode
One-Shot mode
Scanner Redundancy
Normal
Scanner Selection
All compatible scanners
Scanner Timeout
Disabled (no timeout)
Scanner Trigger
Level triggering
Time and Date
9601071200000
Time in Seconds
Disabled
Page 219
nugget
39 Terminal Specifications
A
Default Configuration for RF and Ethernet Network Communications Parameter
Default
Acknowledgement Delay Lower Limit
300 ms
Acknowledgement Delay Upper Limit
5000 ms
Controller Connect Check Receive Timer
60 seconds
Controller Connect Check Send Timer
35 seconds
Controller IP Address
0.0.0.0
Default Router
0.0.0.0
Host IP Address
0.0.0.0
Maximum Retries
7
Network Activate
Disabled
Network Loopback
Disabled
Network Port
23 (Telnet) for a TCP/IP network 5555 for a UDP Plus network
RF Domain
0
RF Inactivity Timeout
5 seconds
RF Roaming Flag
Allowed
RF Security Identification (ID)
None
RF Transmit Mode
BFSK
RF Wakeup On Broadcast
No (disabled)
Subnet Mask
255.255.255.0
TCP/IP Maximum Transmit Timeout
32 seconds
Terminal IP Address
0.0.0.0
A-9
Page 220
TRAKKER Antares 248X Stationary Terminal User’s Manual nugget 39
Default Configuration for Serial Network Communications
A-10
Parameter
Default
Baud Rate
19200
Configuration Commands Via Serial Port
Enabled without TMF
Data Bits
7
End of Message (EOM)
\x03 (hexadecimal value for ETX)
Flow Control
None
Handshake
Disabled
LRC (Longitudinal Redundancy Check)
Disabled
Multi-Drop Address
A
Parity
Even
Poll (Polling)
Disabled
Protocol
Configurable
Start of Message (SOM)
\x02 (hexadecimal value for STX)
Stop Bits
1
Timeout Delay
10 seconds