Page 171

nugget

39 Using Custom Applications and Screen Mapping

5

EZBuilder contains: •

EZBuilder software

•

Microsoft Visual C++ version 1.5X

•

Application Simulator

•

PSK libraries

•

FileCopy utility

•

Sample EZBuilder programs

•

EZBuilder Getting Started Guide

•

EZBuilder Tutorial

Using EZBuilder, you enter simple commands to create menus, screens, and transactions and to define menu items, labels, and data fields. You can also set attributes, define function keys, and specify other processing, such as calculations, for the application. Once you have defined the application, EZBuilder generates the application program code. The Application Simulator mimics a TRAKKER Antares terminal and lets you test the application on your computer.

Converting Applications Between JANUS and TRAKKER Antares You can develop applications that run on both the JANUS devices and the TRAKKER Antares terminals. However, there are some differences that you need to plan for in your applications. The TRAKKER Antares is an intelligent terminal. A JANUS device is a DOS-compatible computer. Because of these differences, there are some features and functions that are different between the JANUS PSK and the TRAKKER Antares PSK. In general, a C/C++ application written for TRAKKER Antares terminals requires minor changes to run on a JANUS device. However, an application written for a JANUS device may require more changes to work properly on a TRAKKER Antares terminal. JANUS applications developed with the JANUS PSK and compiler libraries are relatively easy to convert to an application for the TRAKKER Antares terminals. There are several methods you can use to convert applications to and from JANUS devices and TRAKKER Antares terminals. For help on converting applications, see the TRAKKER Antares Programmer’s Software Kit Reference Manual.

Converting IRL Programs Between the 9560 and TRAKKER Antares One main difference between the T248X and the 9560 stationary terminal is the type of program or application you can run on the terminal. The T248X can run a Microsoft C/C++ application while the 9560 terminal runs IRL (Intermec Reader Language) programs.

5-7

Page 172

TRAKKER Antares 248X Stationary Terminal User’s Manual nugget 39 The TRAKKER Antares terminals support IRL by using IRL to C conversion programs. You can convert IRL programs to Microsoft C/C++ applications that use the TRAKKER Antares PSK functions. For information about converting IRL programs, contact your local Intermec service representative. You can also convert your IRL program by developing a new C/C++ application using the TRAKKER Antares Programmer’s Software Kit (PSK) or EZBuilder and Microsoft C/C++ functions. If you are using the T248X in a CrossBar network, the application needs to send and receive data through COM2. Once your application is converted, you can download the application to the T248X and begin using it in your network.

Converting the Application to a Binary File For your application to run on the T248X, it must be stored as an executable binary file (*.BIN) instead of an executable file (*.EXE). Use the EXE2ABS.EXE program that comes with the TRAKKER Antares PSK or EZBuilder to convert the file. Note: The FileCopy utility or the EZBuilder “download” tool will automatically convert an executable file (*.EXE) to an executable binary file (*.BIN) when you download the file. If you download the applications using another method, you need to convert the application to a binary file. To convert an executable file to a binary file 1. Use the TRAKKER Antares PSK or EZBuilder to develop the application. 2. Convert the application from an executable file to a binary file by typing this command on your development PC: drive:\intermec\imt24\lib\exe2abs filename.exe

The conversion application (EXE2ABS.EXE) creates an executable binary file named FILENAME.BIN. For example, if your application is named SHIPPING.EXE and the Intermec directory is on drive C, type this command on your PC: c:\intermec\imt24\lib\exe2abs shipping.exe

The conversion application creates the SHIPPING.BIN file. 3. If you have a T2480/1 with Ethernet or a T2485/6 and plan to download applications and files from the Model 200 Controller or host via the 2.4 GHz RF network or the Ethernet network, copy all the binary application files and any data files to a 3.5-inch disk. Continue with the instructions for “Using the Model 200 Controller to Download Applications” later in this chapter.

5-8

Page 173

nugget

39 Using Custom Applications and Screen Mapping

5

Using the Serial Port to Transfer Applications and Files You can download or upload applications and files between a PC or host computer and the T248X using serial communications. You connect the terminal’s serial port to the host by using: •

COM1

•

COM2

•

COM4 with the adapter cable accessory (Part No. 067185)

For help connecting the terminal, see Chapter 2, “Installing the Terminal.” Once the terminal is connected, you can transfer files to or from a terminal. There are two ways to transfer files: •

Use the FileCopy utility that ships with the TRAKKER Antares Programmer’s Software Kit (PSK) and EZBuilder.

•

Use the Receive File or Transmit File reader commands. For help, see Chapter 6, “Reader Command Reference.”

The instructions in this section explain how to use the FileCopy utility to download or upload applications and files to or from the terminal. To run an application on the terminal, it must be stored as an executable binary file (*.BIN). The FileCopy utility will automatically convert any *.EXE file to a binary file (*.BIN) before downloading the file. With the FileCopy utility, you can download either *.EXE or *.BIN application files. Note: If you have a T2485 or T2486, you can download or upload files to or from the terminal using either the serial port or RF communications through the Model 200 Controller or host. To download or upload applications and files to or from the terminal 1. Connect the TRAKKER Antares terminal to your PC. 2. Start Microsoft Windows on your PC 3. From Program Manager, start FileCopy. The TRAKKER Antares FileCopy utility screen appears. FileCopy includes detailed online help. You click the Help button or press F1 anytime to get more information.

5-9

Page 174

TRAKKER Antares 248X Stationary Terminal User’s Manual nugget 39

TRAKKER Antares FileCopy Utility Screen

4. Check the serial port and serial communications parameters to verify that the settings for your PC match the values that are set for the terminal’s serial port. a. Select the COM Port Setup tab to select and configure the following: •

PC COM port

•

TRAKKER Antares COM port

•

Communications Protocol

•

File Transfer protocol

•

Baud rate, parity, data bits, and stop bits b. Select the Serial Communications Setup tab to verify and configure the PC serial communications parameters. c. Use the TRAKKER Antares 2400 Menu System to configure the COM1, COM2, or COM4 serial port parameters on the terminal. For help, see “Configuring the Serial Port Parameters” in Chapter 2. 5. Select the FileCopy tab to download or upload applications and files. a. In the PC filename and path field, type the path and filename (FILENAME.EXE or FILENAME.BIN) for the file on your PC. You can select a previously used filename from a list by clicking on the down arrow. To view a list of available files on your PC, click the Browse button.

5-10

Page 175

nugget

39 Using Custom Applications and Screen Mapping

5 b. In the TRAKKER Antares filename field, type the drive and filename on the terminal. You can select a previously used filename from a list by clicking on the down arrow. Applications must be stored on drive C. Depending on your T248X options and configuration, you can download other files to drive C, D (if available), E, or G (if available).

6. If you are downloading an application and want to run it on the terminal immediately after it is downloaded, enable the Run program check box.

Note: You can also run the application at any time from the terminal. For help, see “Running the Application on the Terminal” later in this chapter. 7. Click Download to copy the file from the PC to the terminal. If you enabled the Run program check box, the terminal boots, resets, and runs the application you downloaded. Otherwise, the current application continues to run on the terminal. Or, click Upload to copy the file from the terminal to the PC. 8. To download or upload another file, repeat Step 5 through Step 7. 9. Click Exit to close the FileCopy utility.

5-11

Page 176

TRAKKER Antares 248X Stationary Terminal User’s Manual nugget 39

Using the Model 200 Controller to Download Applications You can download applications and files to a T248X using network communications. The advantage to downloading files via network (RF or Ethernet) communications is that you can download multiple files to one or more terminals. You use RF or Ethernet communications to download applications from the Model 200 Controller to T248Xs running UDP Plus or from the host to T248Xs running TCP/IP. This section explains how to use the controller to download applications and files. For help downloading files in a TCP/IP network, see Chapter 4, “Operating the Terminal in a Network.” To download applications and files from the Model 200 Controller 1. Copy the applications and files to the controller. 2. Download the applications and files to the T248X. Each step is described in the next sections. Before you start, make sure the T2480/1 with Ethernet or the T2485/6 is communicating with the controller. If you need any help installing or configuring the network, see Chapter 4, “Operating the Terminal in a Network.”

Copying Files to the Model 200 Controller You can use these instructions to copy binary applications and files from a 3.5-inch disk to the Model 200 Controller. To copy applications and files to the controller 1. Insert the 3.5-inch disk that contains the files in the disk drive of the controller. 2. From the main menu sidebar buttons, choose File Handling. The File Handling dialog box appears. 3. In the File Handling list box, select Restore User Files and choose Start. A message box appears telling you to insert the floppy disk in the disk drive of the controller. 4. Choose OK. The Restore User Files dialog box appears. The files on the floppy disk appear in the Available Files list box.

5-12

Page 177

nugget

39 Using Custom Applications and Screen Mapping

5

Restore User Files Dialog Box

5. In the Available Files list box, add all the files that you want to restore to the Selected Files list box. a. Select the file name. b. Choose Select. The file name appears in the Selected Files list box.

If the Selected Files list box shows any files that you do not want to restore, select the file name and choose Remove. 6. Choose Restore Files. The controller restores the files you selected to the USERDATA directory. 7. Remove your disk from the disk drive.

5-13

Page 178

TRAKKER Antares 248X Stationary Terminal User’s Manual nugget 39

Downloading Applications and Files to the T248X Once the applications and files are stored on the Model 200 Controller, you can download applications and files to a T248X running UDP Plus. There are two ways to download files: •

Use the Download Server feature on the controller.

•

Use the Receive File or Transmit File reader commands. For help, see Chapter 6, “Reader Command Reference.”

The instructions in this section explain how to use the Download Server feature on the controller to download applications and files to the terminal. To prepare the terminal •

Make sure the terminal is on and communicating with the controller. Look at the status lights on the left side of the terminal’s screen. If the Network Connect status light is turned on, the terminal is communicating with the controller.

To download applications and files to the T248X 1. If data collection is not started on the Model 200 Controller, choose Start Data Collection from the main menu sidebar buttons. 2. From the main menu sidebar buttons, choose System Maintenance. The System Maintenance dialog box appears. 3. In the System Maintenance dialog box, select Configure Download Server and then choose Start. The Terminal Download Configuration dialog box appears.

5-14

Page 179

nugget

39 Using Custom Applications and Screen Mapping

5

4. From the Terminal Download Configuration dialog box in the Terminals and Groups list box, select a terminal or group of terminals to receive the binary applications and files. For help defining a group of terminals, see “Adding a Group in the Download Server” in Appendix B of the Model 200 Controller System Manual. 5. Choose Edit. The Configure Device Initialization Download dialog box appears.

6. Verify that there are no files (or entries) listed in the Files and Data list box. If there are entries, then choose Clear to remove them. 7. In the Initialization Data box, choose File. 8. In the field, type: \filename where filename is the name of the executable binary application. Or choose Find, select your application, and choose OK. 9. Enable the Binary file check box. 10. Enable the Overwrite option button to overwrite an existing file with the same name. 11. In the Target file name field, type a name if you want to save the file under a different name on the terminal. Do NOT enter a slash or backslash character before the target filename. 12. Choose Add. The file appears in the Files and Data list box with a B for binary in the leftmost column.

5-15

Page 180

TRAKKER Antares 248X Stationary Terminal User’s Manual nugget 39

Configure Device Initialization Download Dialog Box

13. Repeat Steps 7 through 12 to select another application. 14. You can also download files used by your application such as an employee list or a part number list. To download additional files, choose File in the Initialization Data box. Type in the filename including the backslash. Disable the Binary file check box and then choose Add. 15. Choose OK to save your changes and return to the Terminal Download Configuration dialog box. 16. In the Terminals and Groups list box, choose the terminal or group you configured if it is not already highlighted and marked with an asterisk. 17. Choose Download. A Download initiated message box appears. 18. Choose OK. The executable binary applications and files are downloaded to the terminal or group of terminals usually within a few seconds. If you are downloading the applications and files to many terminals or there is a lot of radio traffic in your 2.4 GHz RF network, the download may take longer. All files are downloaded and stored on the terminal’s flash drive C. 19. Choose Close to close the dialog box and return to the System Maintenance dialog box. To run an application, continue with the instructions in the next section.

5-16