Page 71

nugget

39 Operating the Terminal in a Network

4

Planning the Network Connection To use the 2461 in the Ethernet network, you need these minimum requirements: • •

DCS 300 (2461 with UDP Plus) Ethernet connector in your network

You need to work with your network administrator to plan and assign the IP address for each device in the Ethernet network. For a 2461 with UDP Plus, you must also assign an IP address to the DCS 300.

Configuring the DCS 300 The DCS 300 supports and manages communications with other devices in the Ethernet network. When you install and configure the server, you identify the host computer(s) and 2461 terminals in your network. The terminals communicate through the server with your host by using UDP Plus protocol. For help installing the server, see the DCS 300 System Manual (Part No. 067296). Note: You can use a 2461 running TCP/IP protocol and the DCS 300 in a pass-through network. You establish a direct TCP/IP socket connection from the 2461 to the host through the server. For more information, see the DCS 300 System Manual. To have the 2461 communicate with the server, you must configure these parameters on the server: •

Configure the Ethernet network.

•

Configure the UDP Plus network.

•

Enter the IP address for each 2461.

•

Enable all 2461 terminals.

•

Define the host environment parameters, which includes configuring for screen mapping or client/server applications.

To do screen mapping on the DCS 300, you must: • create the script file using the Script Builder tool on the server.

• create an application using EZBuilder and download it to the T2461.

4-13

Page 72

TRAKKER Antares 246X Stationary Terminal User’s Manual nugget

39

Configuring the 2461 Terminal When you install the 2461 terminal in a network, you must configure a set of network parameters that control how the terminal communicates in the network. Configure the network parameters by scanning the configuration command from a Code 39 or Code 93 bar code label. The configuration commands are listed alphabetically by command name in Chapter 8, “Configuration Command Reference.” The set of network parameters you must configure depends on whether you install the terminal on the same IP subnetwork as the DCS 300 (UDP Plus) or host (TCP/IP), or on a different subnetwork. The next table lists the parameters you configure in each type of network. Same IP

Different IP

Subnetwork?

Subnetwork?

Time and date

X

X

Network activate

X

X

Controller IP address (UDP Plus)

X

X

Network Parameters

Host IP address (TCP/IP)

X

X

Terminal IP address

X

X

Network port

X

X

Default router

X

Subnet mask

X

Using the Status Lights to Monitor Network Communications After you have configured the devices in the Ethernet network, you can begin using the application on the 2461 terminal to collect and transmit data. If the 2461 is communicating with your host computer, the terminal will connect and begin running the application that shipped on the terminal. You can begin using the terminal to collect data. As you use the 2461 terminal to collect data, status lights help you monitor network communications on the terminal. Use the Network Connect light to monitor communications between the 2461 and other devices in the Ethernet network.

4-14

Page 73

nugget

39 Operating the Terminal in a Network

4

Using the Status Lights to Monitor Network Communications You See These Lights

Status of Communications

What You Need to Do

Network Connect status light is turned off.

No communications.

You may need to enable the Network Activate command. Make sure the terminal is configured correctly to communicate in your network. For help, see “Configuring the 2461 Terminal” earlier in this chapter.

The 2461 is not connected to the Ethernet network.

Partial communications. The 2461 with UDP Plus is trying to establish communications with the DCS 300, but it is not connected. The Network Connect status light blinks.

The Network Connect status light remains on.

You may need to configure the terminal to communicate with other devices in the Ethernet network. For help, see “Configuring the 2461 Terminal” earlier in this chapter.

Note: The Network Connect status light does not blink on a 2461 with the TCP/IP protocol.

You may also need to configure the server (UDP Plus) or host. Make sure the terminal is configured correctly and enabled. Make sure the server is turned on and data collection is started.

Normal communications. The 2461 can communicate with the DCS 300 (UDP Plus) or host (TCP/IP).

You can send and receive data between the terminal and the server or host.

4-15

Page 74

TRAKKER Antares 246X Stationary Terminal User’s Manual nugget

39

Configuring the 2461 Over the Network You can remotely configure a 2461 terminal by using one of these methods: •

Send a command from the DCS 300 (UDP Plus network only).

•

Send a command from an application on the host computer.

Once the terminal is communicating, you can configure bar code symbologies and send operating commands. You cannot configure any of the Ethernet network parameters, such as terminal IP address, over the network. Note: You can configure the terminal locally by scanning a command from a Code 39 or Code 93 bar code label. For help, see Chapter 3, “Configuring the Terminal.”

Configuring the 2461 From the DCS 300 If your terminal is configured for UDP Plus, you can use the DCS 300 to configure one or more 2461 terminals in your Ethernet network. You can also send reader commands such as Delete File to one or more terminals. This method is very fast and efficient if you need to change the same configuration parameters for several terminals in one area. For example, you may want to set the Beep Volume to very loud for all the terminals in one area. Note: You can configure a 2461 from the DCS 300, but you cannot get configuration data from the terminal. To send commands from the DCS 300

1. Using the Download Server feature on the DCS 300, select the terminal or group to which you want to download the configuration commands. For help on configuring a group of terminals, see the DCS 300 System Manual. Note: You can continue running an application on the 2461 while configuring the terminal from the DCS 300. 2. Choose the Command option button. 3. Enter the reader or configuration command and choose Add. The command appears in the Files and Data box.

4-16

Page 75

nugget

39 Operating the Terminal in a Network

4

For example, enter this command to set the Beep Volume to very loud: $+BV4

For a list of reader commands, see Chapter 7, “Reader Command Reference.” For a list of configuration commands, see Chapter 8, “Configuration Command Reference.” Note: You can set the Postamble or Preamble command to use characters from the extended ASCII character set. 4. Repeat Step 3 to add another reader or configuration command, or choose OK. 5. To save the configuration changes in flash memory on the 2461, enter this reader command as the last command and choose Add: .+1

Otherwise, the commands only change the runtime configuration. 6. Choose Download to download the commands and change the configuration of the terminals selected.

Configuring the 2461 From the Host You can use an application on the host computer to configure one 2461 terminal. For example, you may want to change the Beep Volume command. To send and receive configuration data or files, you need to write an application for the host that can communicate with the DCS 300 in a UDP Plus network or directly in a TCP/IP direct connect network. UDP Plus is an Intermec value-added protocol. TCP/IP is an industry standard protocol. For help, see “About Network Connectivity and Protocols” later in this chapter.

Configuring the 2461 in a UDP Plus Network To send and receive configuration data, you need to write an application for the host that can communicate with the DCS 300. For help, see the DCS 300 Technical Reference Manual (Part No. 067717). You use the Terminal Message Format (TMF) protocol to send and receive transactions between the host application and the terminal. Note: You can continue running an application on the 2461 while configuring the terminal.

4-17

Page 76

TRAKKER Antares 246X Stationary Terminal User’s Manual nugget

39

To set up the DCS 300

•

Configure a peer-to-peer destination name for the host application. Create a transaction ID, $NGCFGRSP, that will be routed to this destination name. The server uses the transaction ID to route responses from the 2461 back to the host application. $NGCFGRSP is a special transaction ID that the server uses to forward configuration response data from a terminal. All configuration responses will be routed with the $NGCFGRSP transaction ID. The server cannot keep track of multiple applications sending reader or configuration commands. If you have two host applications sending reader or configuration commands, they must both be configured to receive the $NGCFGRSP transactions, and therefore both will receive all responses from all 2461 terminals.

To set up the host computer

•

Verify that you can communicate with the DCS 300.

To set up the application

•

Prepare and write a host application that can communicate with the server and send transactions to and receive transactions from the 2461 in this format: transaction header

TMF field configuration command where:

4-18 transaction header is a 96-byte field containing the message number, date and time, source application ID, destinations application ID, transaction ID, and other information. You must set the system message (SYS$MSG) flag to E in the transaction header. For help, see the DCS 300 Technical Reference Manual.

TMF field is a 2-byte field containing one of these values: CG

Configuration Get request sent from the host application.

Cg

Configuration Get response sent from the 2461 to the host.

CS

Configuration Set request sent from the host application.

Cs

Configuration Set response sent from the 2461 to the host.

Page 77

nugget configuration command

39 Operating the Terminal in a Network

4 is the reader or configuration command or commands you want to set on the terminal, or the current value you want to retrieve from the terminal. To save configuration changes in flash memory, send the reader command .+1 as the last command. For a list of commands, see Chapter 7, “Reader Command Reference” or Chapter 8, “Configuration Command Reference.”

To see examples of the host application transactions, see “Example 1” and “Example 2” later in this section.

Configuring the 2461 in a TCP/IP Direct Connect Network To send and receive configuration data, you need to write an application for the host that can communicate with a 2461 directly through the Ethernet network. You use the Terminal Message Format (TMF) protocol to send and receive transactions between the host application and the terminal. For more information on sending and receiving files in an application, see “Transferring Files in a TCP/IP Direct Connect Network” later in this chapter. Note: You can continue running an application on the 2461 while configuring the terminal from the host. To set up the host computer

•

Verify that you can communicate with the 2461 terminal.

To set up the application

•

Prepare and write a host application that can communicate with the 2461. Configuration commands must be sent to network port 6000 on the terminal. Message transactions to and receive transactions from the 2461 on network port 6000 must conform to the following format: TMF field configuration command

4-19

Page 78

TRAKKER Antares 246X Stationary Terminal User’s Manual nugget

39 where: TMF field configuration command is a 2-byte field containing one of these values: CG

Configuration Get request sent from the host application.

Cg

Configuration Get response sent from the 2461 to the host.

CS

Configuration Set request sent from the host application.

Cs

Configuration Set response sent from the 2461 to the host.

is the reader or configuration command or commands you want to set on the terminal, or the current value you want to retrieve from the terminal. To save configuration changes in flash memory, send the reader command .+1 as the last command. For a list of commands, see Chapter 7, “Reader Command Reference” or Chapter 8, “Configuration Command Reference.”

Example 1

In the host application, you want to get the current values of two configuration commands from the 2461. Send this transaction from the host application: CG$+NABV

Note: The transaction header is not shown in this example. You do not need a transaction header for a host application in a TCP/IP network. where:

4-20

CG is a TMF Configuration Get request.

$+ is the Change Configuration reader command.

NA is the Network Activate configuration command.

BV is the Beep Volume configuration command.

Page 79

nugget

39 Operating the Terminal in a Network

4

The 2461 returns this transaction to the host application. Cg$+NA1BV4 where: Cg is a TMF Configuration Get response.

$+ is the Change Configuration reader command.

NA1 means the Network Activate configuration command is currently set to a value of 1, which means that the Ethernet network is enabled.

BV4 means the Beep Volume configuration command is currently set to a value of 4, which is a very loud beep volume.

Example 2

In the host application, you want to set the value for two configuration commands on the 2461. Send this transaction from the host application: CS$+BV3KA1

Note: The transaction header is not shown in this example. You do not need a transaction header for a host application in a TCP/IP network. where: CS is a TMF Configuration Set request.

$+ is the Change Configuration reader command.

BV3 sets the Beep Volume configuration command to a value of 3, which is a very loud beep volume.

KA1 sets the Keypad Caps Lock configuration command to a value of 1, which enables the Keypad Caps Lock.

The 2461 returns this transaction to the host application. Cs$+BV3KA1 where: Cs is a TMF Configuration Set response.

$+ is the Change Configuration reader command.

BV3 means the Beep Volume configuration command has been changed to a value of 3, which is a loud beep volume.

KA1 means the Keypad Caps Lock configuration command has been changed to a value of 1, which enables the Keypad Caps Lock.

4-21

Page 80

TRAKKER Antares 246X Stationary Terminal User’s Manual nugget

39

Transferring Files in a TCP/IP Direct Connect Network You can use an application on the host computer to transfer files and send data between the terminal and host in a TCP/IP direct connect network. To initiate file transfers from the host, you need to write a host application that can communicate directly with a 2461. You use the file management reader commands such as Receive File and Transmit File to transfer files between the 2461 and the host. For help, see Chapter 7, “Reader Command Reference.” To initiate file transfers from the terminal, you do not need to develop a host application as described in this section. You can use the Receive File and Transmit File within a terminal application or by scanning bar code labels. For help, see Chapter 7, “Reader Command Reference.” Note: You can continue running an application on the 2461 while configuring the terminal or transferring files from the host. To use the built-in TFTP client on the 2461, you need the following: •

TFTP (Trivial File Transfer Protocol) server must be running on the host.

•

TFTP server must be running on at least a Pentium processor or equivalent.

•

2461 terminal must be communicating with the host that is running the TFTP server.

•

The TFTP server or some other application on the host must be able to send the reader command on the network.

To transfer files or send configuration data from the host

1. Make sure the TFTP server is running on the host and the 2461 is communicating with the host. 2. Start the host application that can send reader commands to the terminal. 3. Send the two-character TMF code, CS (Configuration Set request) followed by the reader or configuration command. For help on TMF, see “Configuring the 2461 in a TCP/IP Direct Connect Network” earlier in this chapter. For example, to send the application INVENTRY.BIN from drive C on the host to drive C on the 2461, enter this command: CS.%R,c:inventry.bin,c:inventry.bin

For command information, see Chapter 7, “Reader Command Reference” or Chapter 8, “Configuration Command Reference.” CLIENT.CPP is the source for a sample application you can run on the host. You can use CLIENT.CPP to send reader commands to the 2461 and receive the resulting messages.

4-22