For the Intermec 2460 and Intermec 2461

Page 1

User’s Manual P/N 068575-002

TRAKKER Antares 246X Stationary Terminal ®

™

Page 2

Intermec Technologies Corporation 6001 36th Avenue West P.O. Box 4280 Everett, WA 98203-9280 U.S. service and technical support: 1-800-755-5505 U.S. media supplies ordering information: 1-800-227-9947 Canadian service and technical support: 1-800-688-7043 Canadian media supplies ordering information: 1-800-268-6936 Outside U.S. and Canada:

Contact your local Intermec service supplier.

The information contained herein is proprietary and is provided solely for the purpose of allowing customers to operate and/or service Intermec manufactured equipment and is not to be released, reproduced, or used for any other purpose without written permission of Intermec. Information and specifications in this manual are subject to change without notice. 1999 by Intermec Technologies Corporation All Rights Reserved The word Intermec, the Intermec logo, JANUS, IRL, TRAKKER, Antares, Adara, Duratherm, EZBuilder, Precision Print, PrintSet, Virtual Wedge, and CrossBar are either trademarks or registered trademarks of Intermec Technologies Corporation. Throughout this manual, trademarked names may be used. Rather than put a trademark ( or ) symbol in every occurrence of a trademarked name, we state that we are using the names only in an editorial fashion, and to the benefit of the trademark owner, with no intention of infringement.

Page 3

Manual Change Record This page records changes to the manual. The manual was released at Revision 001.

Revision

Date

Description of Change

001

9/98

Original release.

002

3/99

Updated the manual as follows: •

Added information about using the TRAKKER Antares CrossBar adapter to connect the 2460 to a 9154/9161 controller.

•

Revised the Receive File and Transmit File reader commands to include information on converting 7-bit ASCII files to/from 8-bit binary files during the file transfer.

•

Added the Status Lights Control reader command.

•

Added a long range laser scanner option to the Scanner Selection configuration command.

•

Made minor corrections and changes throughout the manual.

Page 4

blank page

Page 5

Contents

Contents Before You Begin xiii Warranty Information xiii Safety Summary xiii Warnings and Cautions xiv About This Manual xiv

1

Introducing the 246X Stationary Terminal What Are the 246X Stationary Terminals? 1-3 Models and Options for the 246X Terminals 1-3 Standard Features 1-4 Options 1-4 Accessories for the Terminal 1-4 Understanding the Terminal Connectors 1-5 Using the Status Lights 1-6 Understanding the Terminal’s Status Beeps 1-7 Learning About the Power Supply and Backup Battery 1-8 Understanding the Backup Battery 1-8 Recognizing a Low or Discharged Backup Battery 1-9 Defining the Terminal’s Memory and Drives 1-9 Where Do You Go From Here? 1-10

2

Installing the Terminal Preparing to Install the Terminal 2-3 Installing the Terminal and Connecting External Devices 2-3 Mounting the Terminal 2-4 Connecting the Power Supply 2-5 Connecting Input Devices 2-6 Connecting a Keyboard 2-7 Connecting to Serial Devices and Networks 2-8 Connecting to an Intermec CrossBar Network 2-9 Connecting Directly to an Ethernet Network 2-12 Turning On the Terminal for the First Time 2-13 Charging the Backup Battery 2-14 v

Page 6

TRAKKER Antares 246X Stationary Terminal User’s Manual

Configuring the Terminal to Communicate in Your Network 2-14 Setting the Time and Date 2-14 Configuring the Serial Port Parameters 2-16 Configuring the Ethernet Parameters 2-17 Starting the Application and Using the Terminal 2-18 Turning the Terminal On and Off 2-18

3

Configuring the Terminal How to Configure the Terminal 3-3 Learning About Configuration Parameters 3-3 Choosing the Symbologies the Terminal Decodes 3-4 Specifying How the Terminal Will Communicate 3-4 Controlling How the Terminal Will Operate 3-5 Configuring the Terminal by Scanning Bar Codes 3-5 Scanning Bar Codes to Enable Symbologies 3-7 Saving Configuration Changes in Flash Memory 3-9 Restoring the Terminal’s Default Configuration 3-10 Upgrading the Firmware 3-10

4

Operating the Terminal in a Network Using Serial Communications on the Terminal 4-3 How the 246X Fits Into Your Serial or CrossBar Network 4-3 Identifying the COM Ports 4-6 Choosing a Communications Protocol 4-6 Binary Protocol 4-7 Configurable Protocol 4-7 Master Polling Protocol 4-8 Multi-Drop Protocol 4-8 Polling Mode D Protocol 4-9 Configuring the Serial Port Parameters 4-9 Configuring the Terminal Via the Serial Port 4-9 Using Ethernet Communications on the Terminal 4-12 How the 2461 Fits Into Your Ethernet Network 4-12 Planning the Network Connection 4-13 Configuring the DCS 300 4-13 vi

Page 7

Contents

Configuring the 2461 Terminal 4-14 Using the Status Lights to Monitor Network Communications 4-14 Configuring the 2461 Over the Network 4-16 Configuring the 2461 From the DCS 300 4-16 Configuring the 2461 From the Host 4-17 Configuring the 2461 in a UDP Plus Network 4-17 Configuring the 2461 in a TCP/IP Direct Connect Network 4-19 Transferring Files in a TCP/IP Direct Connect Network 4-22 About Network Connectivity and Protocols 4-27

5

Programming the Terminal How to Download and Run Applications 5-3 About the TRAKKER Antares Programmable Terminals 5-4 Creating Applications for the Terminal 5-6 Using the PSK or EZBuilder to Develop Applications 5-6 Converting Applications Between JANUS and TRAKKER Antares 5-7 Converting IRL Programs Between the 95XX and 246X Terminal 5-7 Converting the Application to a Binary File 5-8 Using the Serial Port to Transfer Applications and Files 5-9 Using the DCS 300 to Download Applications 5-12 Copying Files to the DCS 300 5-12 Downloading Applications and Files to the 2461 5-14 Troubleshooting Applications 5-17

6

Troubleshooting Finding and Solving Problems 6-3 Problems While Operating the Terminal 6-4 Problems While Configuring the Ethernet Network 6-6 Problems While Configuring the Serial Network 6-7 Problems While Scanning Configuration Commands 6-8 2461 Will Not Communicate With Ethernet Network Devices 6-9 Problems Transmitting Data Through the Serial Port 6-9 Problems Transmitting Data Through the DCS 300 6-10 Bar Code Labels Will Not Scan 6-11 vii

Page 8

TRAKKER Antares 246X Stationary Terminal User’s Manual

Booting and Resetting the Terminal 6-13 Booting the Terminal 6-13 Booting the Terminal on Resume 6-13 Using the Boot Terminal Bar Code 6-14 Resetting the Terminal 6-14

7

Reader Command Reference Using Reader Commands 7-3 Using Accumulate Mode 7-3 Enter Accumulate Mode 7-5 Backspace 7-5 Clear 7-6 Enter 7-6 Exit Accumulate Mode 7-6 Operating Reader Commands 7-7 Boot Terminal 7-7 Change Configuration 7-8 Default Configuration 7-8 Multiple-Read Labels 7-9 Reset Firmware 7-9 Save Configuration in Flash Memory 7-10 Scanner Trigger On and Off 7-10 Set Time and Date 7-11 Status Lights Control 7-12 File Management Reader Commands 7-13 Abort Program 7-14 Delete File 7-14 Receive File 7-15 Receive File Through the Serial Port 7-15 Receive and Convert 7-Bit ASCII Files to 8-Bit Binary Files 7-17 Receive File Via Network Communications 7-19 Rename File 7-21 Run Program 7-22 Transmit File 7-23 Transmit File Through the Serial Port 7-23 Transmit and Convert 8-Bit Binary Files to 7-Bit ASCII Files 7-25 Transmit File Via Network Communications 7-27 viii

Page 9

Contents

8

Configuration Command Reference Using Configuration Commands 8-3 Configuration Commands Listed by Category 8-4 Entering Variable Data in a Configuration Command 8-6 Append Time 8-7 Automatic Shutoff 8-7 Baud Rate 8-9 Beep Volume 8-11 Character Set 8-12 Codabar 8-14 Code 11 8-15 Code 16K 8-16 Code 2 of 5 8-17 Code 39 8-18 Code 49 8-22 Code 93 8-23 Code 128 8-24 Command Processing 8-25 Configuration Commands Via Serial Port 8-28 Controller IP Address 8-30 Data Bits 8-32 Decode Security 8-33 Default Router 8-34 Dynamic Host Configuration Protocol (DHCP) 8-36 End of Message (EOM) 8-37 ix

Page 10

TRAKKER Antares 246X Stationary Terminal User’s Manual

Flash Memory Configuration 8-39 Flow Control 8-40 Handshake 8-42 Host IP Address 8-43 Interleaved 2 of 5 8-45 ISBT Code 128 8-47 Keypad Caps Lock 8-52 Keypad Clicker 8-53 LRC (Longitudinal Redundancy Check) 8-54 MSI 8-55 Multi-Drop Address 8-56 Network Activate 8-57 Network Port 8-58 Parity 8-60 Plessey 8-61 Poll (Polling) 8-62 Postamble 8-64 Preamble 8-65 RAM Drive Size 8-66 Resume Execution 8-68 RS-232 or RS-422/485 COM2 Interface 8-69 Scan Ahead 8-70 Scanner Mode 8-71 Scanner Redundancy 8-72 Scanner Selection 8-73 Scanner Timeout 8-74 x