Page 21

nugget fontInstalling the Terminal and Connecting Devices

Charging the Backup Battery The backup battery backs up all memory and the real-time clock in case of a power failure. The backup battery is shipped inside the terminal, but it may not be fully charged. You need to fully charge the backup battery. You can operate the terminal while the backup battery is charging. Note: To guarantee data retention, you need to fully charge the backup battery before you use the terminal for the first time. To charge the backup battery

1. Make sure the terminal is connected to an external power supply. The terminal must be connected to either the DC power supply that is connected to the vehicle battery or to the AC power supply and a powered electrical outlet. 2. Let the power supply charge the backup battery for 14 hours to fully charge the backup battery.

Turning On the Terminal for the First Time Once the power supply is connected and you have installed the terminal, you are ready to turn on the terminal. To turn on the terminal f

1. Press the key on the function keypad. The terminal runs POST (power-on self test) and then the Boot Menu appears.

BOOT

MENU

F1

-

Boot

F2

-

Run

F3

-

Power

POWER

DOWN

System Loader

IN

Down

60

SEC 2455G.019

Note: If the backup battery charge is low and the terminal fails POST, a POST results screen appears. If the backup battery is the only failed test, press or to exit the screen. If any other test failed, contact your local service representative before using the terminal.

] b

21

Page 22

TRAKKER Antares 2455 Getting Started Guide nugget font b

2. Press to boot the terminal and initialize the firmware. The TRAKKER Antares screen appears.

VERSION 4.XX COPYRIGHT 1996-1998

2455G.020

Next, either a sample application screen or a terminal emulation (TE) application welcome screen appears. For example:

1996/01/01

12:00:00

Intermec TRAKKER Antares 3270 Terminal Emulation Version 5.X

2455G.022

Note: On a T2455 loaded with terminal emulation, you may need to press create the TE configuration file.

to

3. Configure the RF communications parameters so that you can begin using the terminal. Follow the instructions for “Connecting to an RF Network“ later in this section.

22

Page 23

nugget fontInstalling the Terminal and Connecting Devices

Connecting to an RF Network The TRAKKER Antares 2455 terminal can communicate with a host computer in Intermec’s 2.4 GHz RF network through the Model 200 Controller, the DCS 300 Server, or directly through the access points. Host TCP/IP Direct Connect

UDP Plus

Ethernet

Access point

T2455

DCS 300

2455G.024

Access point

T2455

The terminal uses one of these RF network protocol options to communicate with other devices: •

UDP Plus

•

TCP/IP

The T2455 ships with only one of these RF network protocols. To configure the T2455 to use RF communications

1. Configure the Model 200 Controller (UDP Plus), DCS 300 Server (UDP Plus), or host (TCP/IP). For help, see your controller or server system manual. 2. Configure the access point. For help, see your access point user’s manual. 3. Configure each T2455 terminal. You need to set these network parameters: • • • • • • •

Time and date Network activate (2.4 GHz) Controller IP address (UDP Plus) or Host IP address (TCP/IP) Terminal IP address RF domain RF security identification (ID) Network port (TCP/IP)

23

Page 24

TRAKKER Antares 2455 Getting Started Guide nugget font

Note: If the T2455 is on a different IP subnetwork from the controller, server, or host, you must also configure the default router and subnet mask. For help, see the next section, “Using the Menu System to Configure the Terminal.”

Using the Menu System to Configure the Terminal You use the TRAKKER Antares 2400 Menu System to set serial port or network parameters on the T2455. To configure the terminal or scan this bar code to access the TRAKKER Antares

1. Press 2400 Menu System:

Enter Test and Service Mode

*..-.* *..-.*

The Main Menu appears.

2455G.026 b

2. Choose the System Menu and then press . Use the Set Time and Date option to set the current time and date. For help using the menu system, press .

?

3. Press to exit the System menu. Choose the Configuration Menu and then press . You can configure the network parameters or serial port parameters using the Communications Menu.

?

4. Press to exit each screen or menu. When prompted, save your changes in RAM and flash memory.

24

Page 25

nugget fontUsing the Function Keypad

Using the Function Keypad The T2455 terminal has a function keypad below the screen that has these keys: • h Display contrast key

•

F1 through F10 function keys

• •

Function Left key f Suspend/Resume key

If your application can receive all data from only scanned bar codes and function keys (F1 through F10), you can use the T2455 without a keyboard.

Using the Keyboard The T2455 accessory keyboard is easy to use. Characters, symbols, and functions are printed in four places on or above the keys. The keys are also color-coded to make it easier to remember key combinations. Position on the Keyboard

Color

To Type the Character

Middle of the key or centered above the key

Grey

Press the key.

Left side above the key

Orange

Press the orange

Centered above a numeric key

Green

Press the green key, then the key.

Right side above the key

Blue

Press the blue key, then the key.

key, then the key.

25

Page 26

TRAKKER Antares 2455 Getting Started Guide nugget font

Using the Status Lights You can use the terminal’s status lights to monitor the status of backup battery power, RF network communications, special keys, and bar code scanning. The status lights flash or turn on to indicate the current status. The Power status light is amber and all other lights are green. When you have the terminal turned off (Suspend mode), the status lights are all off. Modifier Good Network Key Read Connect Caps Network Power Lock Transmit

User Defined

* 2455G.027

Developing Applications for the Terminal The TRAKKER Antares terminals ship loaded with a terminal emulation application, a screen mapping application, or a sample application. You can develop your own client/server application for the T2455 and then download the application to the terminal. Intermec has two development tools that you can use to create applications: •

TRAKKER Antares Programmer’s Software Kit (Part No. 065332) has a full set of programming tools to help you create applications for the terminal.

•

EZBuilder™ (Part No. 066381) is a rapid application development tool that provides a quick and easy way to create applications for the terminal.

Where to Find More Information The TRAKKER Antares 2455 Vehicle-Mount Terminal User's Manual (Part No. 067358) contains all of the information necessary to install, configure, operate, and troubleshoot the T2455. Please visit our web site at http://www.intermec.com to access the manual in PDF format. To order printed versions of Intermec manuals, contact your local Intermec representative or distributor.

26

Page 27

nugget fontSpecifications

Specifications Electrical Specifications

Model: Electrical rating:

S

T2455 12V, 4A

Power Specifications

Operating (with power supply):

10V to 36 VDC or 15V to 96 VDC universal power supply

Memory Backup:

Rechargeable NiCad 700 mA battery pack

Memory

• • • •

2MB programmable flash memory, 750K available for use 1MB battery-backed RAM, 512K available for use Extended memory option for an additional 2MB flash Extended memory option for an additional 2MB or 4MB SRAM storage drive

Scanner Cable Accessories

• • • • • •

151X laser scanner cable, 6 feet (Part No. 066845) 151X laser scanner cable, 25 feet (Part No. 067540) 1550 laser scanner cable, 6 feet (Part No. 067541) 1550 laser scanner cable, 25 feet (Part No. 067542) 1551 laser scanner cable, 6 feet (Part No. 067730) 1551 laser scanner cable, 25 feet (Part No. 067731)

Temperature and Environmental Specifications

Operating the terminal: Standard T2455 Cold-Temperature T2455

14°F to +122°F -22°F to +122°F

-10°C to +50°C -30°C to +50°C

Storing the terminal:

-4°F to +122°F

-20°C to +50°C

Relative humidity:

0 to 95% non-condensing

Terminal Dimensions

Length: Height: Depth: Weight:

11.2 in (28.4 cm) 6.0 in (15.2 cm) 4.2 in (10.7 cm) 8.9 lbs (4.04 kg)

Note: The T2455 dimensions are for the T2455 without a keyboard.

27

Page 28