Page 35
nugget
39 AGaramond Chapter 1 - Learning About the Terminal
243X Status Icon Descriptions Icon
Name Battery
Description This icon remains off when you have a charged battery pack in the terminal. The icon turns on when there is a low battery charge and the terminal is on. When the terminal beeps once every 15 seconds, replace the battery pack with a charged battery pack or charge the battery pack as soon as possible.
Network Connect
This icon tells you if the 2435 is connected to your network. The Network Connect status icon may be off, blinking, or on. Protocol TCP/IP
Status Icon Off Not connected.
Status Icon Blinks Not used.
Status Icon On Connected to an access point.
UDP Plus or WTP
Not connected.
Connected to an access point, but not to a DCS 30X.
Connected to a DCS 30X.
When the Network Connect status icon is off, you are not connected to the network. Make sure the Network Activate command is enabled and that the terminal is configured correctly for your RF network. Make sure that you are in range of an access point. In a UDP Plus or WTP network, this status icon is not instantaneously updated, but it does tell you the communications status the last time data was sent or received from the 2435. Network Transmit
This status icon turns on when data is buffered in the RF network interface. The data is either waiting to be transmitted to the DCS 30X or host, or received data has not been accepted by the application on the 2435. When no data is being buffered in the interface, the Network Transmit status icon is off.
Modifier Key
This status icon indicates that one of the modifier keys, such as w, is enabled. When you press another key, the key combination is available to the application. The Modifier status icon turns off unless the second key that you pressed is another modifier key that is different from the first one that you pressed.
Caps Lock
This status icon turns on when you press l r or the orange > key and ^ to enable the Caps Lock feature. When you press l r or the orange > key and ^ again to disable Caps Lock, the icon turns off. If Caps Lock is enabled, this icon remains on until you disable Caps Lock.
User Defined
This icon is user controlled. You can use the Trakker Antares Programmer’s Software Kit (PSK) to program this icon to turn on and off for any task or error within your application. For help, see the Trakker Antares Application Development Tools System Manual (P/N 064433).
Trakker Antares 243X Handheld Terminal User’s Manual
21
Page 36
Chapter 1 - Learning About the Terminal nugget
39 AGaramond
Learning About the Audio Signals The terminal has a beeper that provides you with audio feedback as you use the terminal. For example, you hear a beep tone each time you enter or scan a valid command. You can change the beep volume, beep duration, and beep frequency to meet the needs of your working environment. When you change the beep volume, you also change the keyclick volume if the Keypad Clicker command is enabled. The keyclick is the sound that you hear when you press a key on the terminal. There are three ways to change the beep volume: • Use the keypad. For help, see the next table. • Use the TRAKKER Antares 2400 Menu System. From the Main Menu, choose Configuration Menu, Terminal Menu, and then Beeper. • Use the Beep Volume command. For help, see “Beep Volume” in Chapter 6 of the 2400 Family system manual. Changing Beep Volume With the Keypad Keypad 39-key or 57-key
Do This Press l c.
48-key
Press the green > key, and then press ,.
There are five beep volume levels including off. Each time you press the key sequence the beep volume becomes one level louder. If the volume is at the loudest level and you press the key sequence, the beep volume is turned off. If you press the key sequence again, the volume changes to the quietest level. Note: When you use the keypad to change the beep and keyclick volume, the changes are not saved permanently in flash memory. You can save the changes in flash memory later. For help, see “Exiting Screens and Saving Changes” on page 40. This table lists each audio signal and describes the situations under which they occur. Audio Signal Descriptions
22
Audio Signal High beep
Situation You entered valid data, you entered a valid command, the terminal decoded a label, or the terminal decoded the last row of a two-dimensional bar code.
Low beep (every 15 seconds)
The battery pack is low. You must replace or recharge the battery pack. For help, see “Using the Terminal’s Battery Pack” on page 7.
Three low beeps
You entered or scanned an invalid command or data.
Trakker Antares 243X Handheld Terminal User’s Manual
Page 37
nugget
39 AGaramond Chapter 1 - Learning About the Terminal
Audio Signal Descriptions (continued) Audio Signal Four low beeps
Situation You booted the terminal and the power-on self test (POST) was successful.
Low beep, high beep, low beep, high beep
You booted the terminal and the POST failed. For help, see “Problems While Operating the Terminal” on page 64.
Low beep, high beep
Your 802.1x terminal has been authenticated.
High beep, low beep
Your 802.1x terminal is not authenticated. For help, see “Problems While Configuring 802.1x Security” on page 70.
Click
You pressed a key and the Keypad Clicker command was enabled. To disable the keyclick, see “Keypad Clicker” in Chapter 6 of the 2400 Family system manual.
Using the Terminal’s Serial Port Serial ports, also called COM (communications) ports, are locations from which data can be passed into and out of the terminal. The 243X supports RS-232 serial communications.
COM1 243XU008.eps
243X serial port: This illustration shows the COM1 serial port.
Note: The serial/power connector and the input device connector lead to the same serial port, COM1. Do not connect more than one serial device to the 243X. COM Port Descriptions Port COM1
Description Use for serial port communications on the 243X. You can use a serial cable to connect the 243X to another serial device, such as a modem, a PC, or a printer. If you have a serial connector module, you can also use the input device connector as COM1. For help, see “Learning About the Connector Modules” on page 26.
RF (NET)
Use for RF communications on the 2435. The Trakker Antares PSK functions use NET to designate the RF network port.
Trakker Antares 243X Handheld Terminal User’s Manual
23
Page 38
Chapter 1 - Learning About the Terminal nugget
39 AGaramond
Using the Terminal’s Scanner Do not look directly into the window area or at a reflection of the laser beam while the laser is scanning. Long-term exposure to the laser beam can damage your vision. Avertissement: Ne regardez pas directement la réflexion d’un rayon laser ou dans la fenêtre du laser lorsque celui-ci est en opération. Si vous regardez trop longtemps un rayon laser, cela peut endommager votre vue. You can use the scanner to scan and enter bar code data. When you press the Scan button or one of the side scan buttons, the scanner emits a beam of laser light that is visible on the bar code label as you scan it. The terminal decodes the bar code and enters the data or command you scanned. Note: The Scan button on the keypad and the side scan buttons on the terminal do not activate the tethered input device that may be connected to the terminal. When you unpack the 243X, these bar code symbologies are enabled: • Code 39 • Code 128 • PDF 417 (243X terminals configured for decoded scanning with a tethered PDF 417 scanner only) • UPC/EAN To scan other bar code symbologies, you must enable them on the 243X. For help, find the symbology in Chapter 6 of the 2400 Family system manual. This section describes how to scan a bar code label with the integrated scanner and the tethered PDF 417 scanner. For help using the other input devices, see the instructions that ship with the input device. For help connecting and configuring tethered input devices, see “Input Devices” on page 87. To scan a bar code label with the scanner 1 Press f or ' to turn on the terminal. 2 Hold the terminal at a slight angle a few inches from the bar code label. The scanner must be pointing toward the label. Note: If you have a long range or advanced long range scanner, you may need to hold the terminal further away.
24
Trakker Antares 243X Handheld Terminal User’s Manual
Page 39
nugget
39 AGaramond Chapter 1 - Learning About the Terminal
3 Push the Scan button on the keypad or one of the side scan buttons on the terminal. Or, If you are using a handle, gently pull the trigger.
K
C RO
35
4 *2
* Ss
43
*2
Scan button 35 24
Side scan button (2 places)
C
O 5R
* s KS
35 24
Trigger
243XU012.eps
2435U016.eps
4 Direct the beam so that it falls across all bars in the bar code label. When the terminal successfully reads the label, you will hear a high beep. The green Good Read LED turns on when you successfully scan a bar code label with the integrated scanner or an input device that is connected to the terminal. This LED turns off after 2 seconds unless you start scanning another label. 5 Release the Scan button. Note: You can configure scanning options to scan multiple bar code labels without pressing the Scan button each time. For help, see “Scanning Options” on page 27.
*NANCY* Quiet zone before and after bar code 243XU098.eps
Quiet zone: To successfully read a bar code label, the laser beam in the scan module must see all the bars in a label and a clean, non-printed space, or “quiet zone,” at each end of the label.
Trakker Antares 243X Handheld Terminal User’s Manual
25
Page 40
Chapter 1 - Learning About the Terminal nugget
39 AGaramond
Use the following guidelines to achieve a successful scan: • Hold the terminal so that the scanner is pointing toward the bar code label. Tilt the terminal up or down slightly (20 degrees). • Optimum scan angles vary with the type and print quality of the bar code label, the distance of the scanner from the label, and the lighting in the area. • Do not scan the bar code label “straight on.” In a 2-degree conical “dead zone” directly above the label, the laser beam may reflect back into the scanner window and prevent the terminal from reading the label. At certain angles and straight on, you may not see the laser beam. To scan a bar code label with the tethered PDF 417 scanner 1 Press f or ' to turn on the terminal. 2 Point the scanner slightly above or below the bar code label, and press the scan button or the trigger. 3 Pass the beam over the bar code label in a steady sweeping motion. The terminal emits an audible crackle sound indicating that the terminal is successfully scanning the bar code label. When you get a successful read with the 243X, the Scanner LEDs at the top of the keypad are lit green for 2 seconds, the terminal beeps, and the laser beam turns off.
Learning About the Connector Modules The 243X has two different connector module options.
Serial/power connector
Input device connector
Serial/power connector
Input device connector
Standard Connector Module
Serial Connector Module
243XU009.eps
243XU007.eps
Standard Connector Module The input device connector on the standard connector module supports non-decoded input devices. Non-decoded input devices send the data from the scanned bar code label directly to the 243X. The 243X then translates the data before processing it.
26
Trakker Antares 243X Handheld Terminal User’s Manual
Page 41
nugget
39 AGaramond Chapter 1 - Learning About the Terminal
Serial Connector Module The input device connector on the serial connector module supports decoded input devices. Decoded input devices translate the data from the scanned bar code label before sending it to the 243X. You can also attach a serial device to this input device connector. For help, see “Connecting to a Serial Device or Network” on page 28. Note: The serial/power connector and the input device connector lead to the same serial port, COM1. Do not connect more than one serial device to the 243X. The 243X supports different bar code symbologies depending on the type of input device connected to the terminal. For a list of these symbologies, see “Bar Code Symbologies” on page 86.
Connecting an Input Device 1 Use the appropriate interface cable to attach an input device to the input device connector on the connector module. For help determining which cable to use, see “Input Devices” on page 87. 2 Configure the Scanner Selection command and select the input device that is connected to the terminal. For help determining how to configure the Scanner Selection command, see “Input Devices” on page 87 and “Scanner Selection” in Chapter 6 of the 2400 Family system manual. Note: You must configure the Scanner Selection command. If this command is not defined for the appropriate input device, the scanner trigger on the input device may activate the integrated scanner on the terminal.
Scanning Options After you connect an input device to the 243X, you can modify the following scanner command options to meet your needs: • Decode Security
• Scanner Selection
• Scan Ahead
• Scanner Timeout
• Scanner Mode
• Scanner Trigger
• Scanner Redundancy For more information about these commands, see Chapter 6, “Configuration Command Reference,” in the 2400 Family system manual.
Trakker Antares 243X Handheld Terminal User’s Manual
27
Page 42
Chapter 1 - Learning About the Terminal nugget
39 AGaramond
Connecting to a Serial Device or Network You can physically connect the 243X to a serial device, such as a host computer or printer, through the serial/power connector using a serial adapter cable. If you have a serial connector module, you can use either the serial/power connector or the input device connector to connect to a serial device.
Serial/power connector
Input device connector
Serial Connector Module 243XU007.eps
Serial connector module: This illustration shows you which connectors you can use to connect the 243X to a serial device or network.
Note: The serial/power connector and the input device connector lead to the same serial port, COM1. Do not connect more than one serial device to the 243X. To connect the 243X to a serial device using the serial/power connector 1 Attach a serial device to the serial adapter cable (P/N 216-807-001) (sold and ordered separately). 2 Connect the serial adapter cable to the serial/power connector on the 243X. To connect the 243X to a serial device using the input device connector 1 Attach a serial device to the RS-232 null-modem serial cable (P/N 070268) (sold and ordered separately). 2 Connect the serial cable to the input device connector on the 243X. You can transfer data between the 243X and the serial device. For help, see “Using Serial Communications on the Terminal” on page 51.
28
Trakker Antares 243X Handheld Terminal User’s Manual
Page 43
nugget
39 AGaramond Chapter 1 - Learning About the Terminal
Defining the Terminal’s Drives The terminals come with the following memory and drives. On each drive, filenames are customer defined using eight characters with a threecharacter extension. You cannot define any subdirectories. 2430
2435 750K flash drive
750K flash drive Drive C
2MB (of the total 4MB) flash memory
Drive D or font set
256K configurable RAM drive
Drive E
Optional 2MB or 4MB extended storage drive
Drive C Drive C Drive D or font set
2MB (of the total 4MB) flash memory 256K configurable RAM drive
Drive E 242XU180.eps
Drive G
2430 and 2435 drives: This illustration shows the structure of the terminal drives for the 2430 and the 2435.
Drive C Drive C is a 2MB flash drive. You can use up to 750K of this flash drive to store up to 128 files on drive C. Applications must be stored on drive C. You use standard ANSI C library interface definitions to access the information on this drive.
Drive D or Font Set Drive D (Font Set) is 2MB drive of flash memory that you can configure as drive D. Use this flash drive to store large lookup tables and data files. You can store up to 128 files. You can also order the flash memory to come pre-loaded with a double-byte font set. To configure this flash memory, see “Flash Memory Configuration” in Chapter 6 of the 2400 Family system manual. Note: If you have a terminal with the 802.1x TTLS security option, drive D is not available to store files or double-byte fonts. For more information about configuring 802.1x security, see “Configuring the 802.1x Security Parameters” on page 58.
Trakker Antares 243X Handheld Terminal User’s Manual
29
Page 44
Chapter 1 - Learning About the Terminal nugget
39 AGaramond
Drive E Drive E is a configurable RAM drive (up to 256K). The contents of this drive are erased when you boot or reset the terminal. You can store up to 128 files on drive E, and you can access these files using standard ANSI C functions. By default, the RAM drive is not configured and the memory is available for programmable (Malloc) memory allocations. To configure the RAM drive, see “RAM Drive Size” in Chapter 6 of the 2400 Family system manual.
Drive G (Optional) Drive G is an optional 2MB or 4MB extended storage drive that is only available on the 2430. Use this drive to store large lookup tables and data files. You can store up to 128 files on drive G, and you can access these files using standard ANSI C functions.
Malloc or Free Memory On the terminals, applications are customer defined. You have 512K total RAM that you can use for the application execution space. You can also configure this RAM to be the RAM drive (up to 256K). The remaining RAM is the Malloc/free memory pool. Application execution space
30
+
RAM drive (drive E)
+
Malloc/free memory pool
=
512K RAM
Trakker Antares 243X Handheld Terminal User’s Manual