What’s New y|

This chapter describes the purpose and contents of this addendum. It also summarizes the enhancements and features of the firmware version 6.13 release.

How to Use This Addendum

Read this addendum before you begin using your Trakker Antares terminal.

The hardware and software on Trakker Antares terminals have been updated substantially to improve efficiency and ease of use. These changes are not yet reflected in the user’s manual, but they are described here in detail.

The information in this addendum applies to the Trakker Antares 2420, 2425, 2455, 2460, and 2461 terminals. For more information about the topics covered in this addendum, refer to your user’s manual.

Part Number

Manual with Addendum Trakker Antares 2420 and 2425 Hand-Held Terminal User’s Manual, _064024-007 Trakker Antares 2455 Vehicle-Mount Terminal User’s Manual 067358-004 Trakker Antares 246X Stationary Terminal User’s Manual 068575-003

This addendum contains the latest information about Trakker Antares terminals with firmware version 6.13. If there are any conflicts between the information in the Trakker Antares user’s manual and this addendum, use the information in this addendum.

To learn about your Trakker Antares terminal, use this addendum in conjunction with other Trakker Antares documentation.

What You Will Find in This Addendum

This table summarizes the information in each chapter.

Chapter Summary

1 Describes the purpose and contents of this addendum. It also summarizes the enhancements and features of the firmware version 6.13 release.

2 Contains information about configuring the Trakker Antares terminal to use the TEEE 802.11B High Rate (HR) radio. This chapter only applies to the T2425 and the T2455.

3 Explains how to run and use ROM-DOS on Trakker Antares terminals that are running firmware version 6.12 or higher.

4 Describes changes that have been made to Trakker Antares software and hardware that are not yet reflected in the user’s manual.

1-3

Page 12

Trakker Antares 24XX Terminal User’s Manual Addendum

If You Do Not Have Firmware Version 6.13 If you have an earlier version of firmware, you can download version 6.13 at no charge from the Intermec Web site at www.intermec.com. For help, contact your local Intermec service representative. If you are not going to upgrade to version 6.13, use your Trakker Antares user’s manual and disregard this addendum.

Summary of New Features in Firmware Version 6.13 With firmware version 6.13, several significant changes were made to Trakker Antares hardware and software. These changes include:

You can now use and configure the IEEE 802.11B High Rate (HR) radio option.

You can use ROM-DOS to install and run DOS applications on your terminal.

If you are using 21XX Universal Access Points, you can now roam across subnetworks.

You can configure additional network parameters through the network.

You can create a custom logo that appears on the terminal screen each time the terminal boots.

The Euro symbol ( ) is now supported.

There are now additional 95XX emulation features.

You can now store up to 128 files on each drive.

You can use new diagnostics.

You can now configure the new beep duration command to create the impression of a higher beep volume.

For the UPC/EAN configuration command, you can set expanding zeros for UPC-E, and you can also set new supplementals options.

This information supplements the information provided in your Trakker Antares user’s manual. Please keep this addendum with your user’s manual.

1-4

Page 13

Configuring the 802.11B HR Radio

Page 14

EODQN SDJH

Page 15

Configuring the 802.11B HR Radio

This chapter contains information about configuring the Trakker Antares terminal to use the 802.11B HR radio.

Summary of Radio Frequency Features To communicate through the 2.4 GHz radio frequency (RF) network, all Trakker Antares RF terminals (T2425 or T2455) must contain one of the following types of radios:

WLI-F 2.4 GHz OpenAir frequency hopping spread spectrum

2.4 GHz IEEE 802.11B high rate direct sequence spread spectrum

The radio in each of the terminals must be the same type of radio in the access points. Depending on the type of radio, you must set certain parameters to the same configuration on both the terminal and the access points.

OpenAir Radio To use OpenAir radios in your network, you must set the following parameters:

RF Domain

RF Security Identification

The values for each of these parameters must be the same on the terminals and the access points. Each access point is configured with a different channel/subchannel combination. Note: On the 21XX Universal Access Points, the RF Domain parameter is called the LAN ID (Domain) parameter.

Note: The RF Security Identification parameter is an optional parameter. You only have to set this parameter on the terminal if it is already set on the access points.

802.11B HR Radio To use 802.11B HR radios in your network, you must set the following parameter:

Network name

The value for this parameter must be the same value on the terminals and the access points. You can also set this parameter to “ANY” on the terminal, allowing the terminal to communicate with any access point that has the same radio and is within range. This parameter is case-sensitive.

2-3

Page 16

Trakker Antares 24XX Terminal User’s Manual Addendum

802.11B HR Radio Configuration Commands This section describes the following configuration commands for the 802.11B HR radio:

AP Density

Maximum Sleep Duration

Medium Reservation

Network Name

Power Management

Receive All Multicast

Reservation Threshold

Station Name

Transmit Rate

Transmit Rate Fallback

WEP Encryption

WEP Key 1

WEP Key 2

WEP Key 3

WEP Key 4

WEP Transmit Key

For more information about configuring these commands for your access points, see you access point manual. Note: The Code 39 bar code labels in this chapter show an asterisk (*) at the beginning and end of the human-readable interpretation to represent the start and stop codes. If you are creating your own Code 39 bar code labels, your bar code printing utility may automatically supply the asterisks as the start and stop codes.

2-4

Page 17

Configuring the 802.11B HR Radio

AP Density Purpose:

Controls the roaming sensitivity of the radios. You can use this parameter to virtually reduce the range of the radio. When you increase the AP density, you do not reduce the absolute range of the radio, but the roaming algorithms are modified to allow significant overlap of the radio coverage. Increasing the AP density lets you create a higher performance radio network, but you will need significantly more access points to cover a given area.

Syntax:

LGdata Acceptable values for data are:

Default: Menu System:

1

Low density

2

Medium density

3

High density

Low density From the Main Menu, choose Configuration Menu, then Communications Menu, and then Radio.

Scan:

One of these bar codes:

Low AP Density

*$+LG1* *$+LG1*

Medium AP Density

*$+LG2* *$+LG2*

High AP Density

*$+LG3* *$+LG3*

2-5

Page 18

Trakker Antares 24XX Terminal User’s Manual Addendum

Maximum Sleep Duration Purpose:

Specifies the maximum amount of time the radio is allowed to sleep. Note: Before you set the maximum sleep duration, you must enable the Power Management command.

Syntax:

LIdata Acceptable values for data are from 0 to 65535 ms.

Default: Menu System:

100 From the Main Menu, choose Configuration Menu, then Communications Menu, and then Radio.

Scan:

To set the default maximum sleep duration, scan this bar code:

Default Maximum Sleep Duration

*$+LI100* *$+LI100* Or:

To set the maximum sleep duration: 1.

Scan this bar code:

Enter Accumulate Mode / Set Maximum Sleep Duration

*+/$+LI* *+/$+LI* 2.

Scan a numeric value for data from these bar codes:

*0*

*1*

*2*

*3*

*0*

*2*

*4* *4*

2-6

*1*

*3*

*5*

*5*