Browse
(440) 299-7778
Menu
(440) 299-7778
One-year parts and labor warranty30-day money-back guaranteeEnglishEspañolContact
Page 1 of Intermec 069582 Manual

Manual · Intermec

Intermec 069582 Manual

Manual2 pagesPDF 88 KB

Both pages are below, each with its text.

Download the PDF88 KB

Covers · 1 model

The models it covers

From the manual · read page by page

Key facts from this manual

Each line names its page in the PDF.

Intermec instruction sheet from 2004 for the Trakker Antares 2-pack battery charger, P/N 069582, which charges two lithium-ion packs for the Trakker Antares 241X handheld terminals. It covers placing and powering the charger, loading batteries, charging times, the status LEDs and troubleshooting, with specifications and power cord part numbers.

Device
2-pack charger for up to two battery packs of the Trakker Antares 241X handheld terminals at once p. 1
Batteries
Intermec lithium-ion packs P/N 069428, 069429, 073929 and 073930 p. 1
Power supply
Autoranging external supply P/N 065236 or P/N 073941; AC power cord ordered separately p. 1
Input
12V; 1.7A p. 1
Charging times
1350 mAh single-cell (069428) 1.25 hours; 2700 mAh dual-cell (069429) 2.5 hours; 2400 mAh single-cell (073929) 5 hours; 4800 mAh dual-cell (073930) 9 hours p. 2
Charge cycle
Current limit 1.4 Amps maximum; float voltage 4.2V +50 mV, -100mV p. 1
Temperature
Operating 0°C to 50°C (32°F to 122°F); storage -20°C to 50°C (-4°F to 122°F) p. 1
Size and weight
Approximately 51 x 102 x 102 mm (2 x 4 x 4 in); approximately 198.5 g (7.0 oz) p. 1
Power cords
North and Central America 586105; Europe 586267; United Kingdom 586266; Denmark and Greenland 586283; Italy and Chile 586282; Liechtenstein and Switzerland 586276; South Pacific 586281; China 071918 p. 1
Status LEDs
Yellow: charging or cold; green: fully charged or over heated; off: empty or unplugged; flashing yellow: charge interrupt or timeout p. 2
Related documents
Instructions P/N 069548-002; Trakker Antares 241X Handheld Terminal User's Manual P/N 069538 p. 1

What this manual walks you through

  • Choosing a location for the charger p. 1
  • Connecting the external power supply p. 1
  • Loading and unloading a battery pack p. 2
  • Reading the status LEDs of each slot p. 2
  • Troubleshooting a charger that does not charge or light p. 2

Good to know

  • Use only Intermec-labeled lithium-ion packs P/N 069428, 069429, 073929 or 073930 in the charger. p. 2
  • Remove the battery pack within 24 hours after charging completes. p. 2
  • Do not expose the charger to rain or moisture. p. 1
  • The recommended charging temperature is 25°C (77°F); the charger gets warm in use, which is normal. p. 2

Questions this manual answers

How long does the Intermec 069582 charger take to charge a battery?

A fully discharged pack takes at most 1.25 hours for the 1350 mAh pack (069428) and up to 9 hours for the 4800 mAh pack (073930). p. 2

Which batteries fit the Intermec 069582 2-pack charger?

Intermec lithium-ion packs P/N 069428, 069429, 073929 and 073930 for the Trakker Antares 241X. p. 1

What does a flashing yellow LED mean on the Trakker Antares 2-pack charger?

A charge interrupt or timeout; steady yellow means charging or cold. p. 2

What power supply does the 069582 charger use?

An autoranging external power supply, P/N 065236 or P/N 073941, with an AC power cord ordered separately. p. 1

The file

Size and text

Pages2
PDF88 KB
TextText from the PDF itself.

Every page · 2

Read it here

Each page as it is printed, and its words beside it, so a phone can search and copy them.

Page 1 of Intermec 069582 Manual

The text of page 1, from the PDF itself

Specifications Design and specifications are subject to change without notice. Product

Intermec battery charger (P/N 069582)

Electrical requirements

Input voltage: x 12V; 1,7A

Application

Intermec lithium-ion battery pack (P/N 069428, P/N 069429, P/N 073929, or P/N 073930)

Charge cycle

Current limit: 1.4 Amps maximum Float voltage: 4.2V + 50 mV, - 100mV

Operating environment

Temperature: 0°C to 50°C (32°F to 122°F) Humidity: 0 to 95%, non-condensing

Storage environment

Temperature: -20°C to 50°C (-4°F to 122°F) Humidity: 0 to 95%, non-condensing

Dimensions

Approximately 51 x 102 x 102 mm (2 x 4 x 4 in)

Weight

Approximately 198.5 g (7.0 oz)

Ordering Power Cords for the Battery Charger The AC power cord is ordered separately. If you need to order an Intermec power cord, contact your Intermec sales representative. Country

Part Number

North and Central America

586105Europe586267Denmark and Greenland586283Italy and Chile586282

Liechtenstein and Switzerland

586276United Kingdom586266South Pacific586281China071918

2-Pack Battery Charger Instructions

*069548-002* P/N 069548-002

2-Pack Battery Charger Instructions Use the Trakker Antares® 2-pack battery charger to simultaneously charge up to two battery packs for the Trakker Antares 241X Handheld Terminals. This guide describes how to install and use the charger. Before using the charger, please read this guide and keep it for future reference. For help managing battery power, see your Trakker Antares 241X Handheld Terminal User’s Manual (P/N 069538).

Choosing a Location for the Battery Charger To prevent fire or electric shock, do not expose the battery charger to rain or moisture. Attention Danger: Pour éviter des risques d’incendie ou de choc électrique, ne pas exposer le chargeur de la batterie à la pluie ou à l’humidité. Use these guidelines to choose a location for the charger:

  • Locate a flat, stable, and clean surface that is within 1.5 m (5 ft) of an electrical source (AC outlet).
  • Provide access to the power supply jack on the battery charger and to the battery charger itself so you can easily load and unload batteries.

Connecting the Power Supply Before you can use the battery charger, you will need to have an autoranging external power supply (P/N 065236 or P/N 073941). Plug the external power supply connector into the power supply jack on the battery charger and then connect the AC power cord (ordered separately) to the power supply and to an AC outlet. 6001 36th Avenue West Everett, WA 98203 U.S.A. www.intermec.com © 2004 Intermec Technologies Corp. All Rights Reserved

Charging a Battery Pack You can charge up to two Intermec-labeled lithium-ion battery packs simultaneously, using either slot. The charging times indicate the

Page 2 of Intermec 069582 Manual

The text of page 2, from the PDF itself

maximum amount of time to charge a fully discharged battery. It may take less time depending on the state of the battery charge. Battery Pack Charging Times Battery Pack

Charging Time

1350 mAh single-cell (P/N 069428)

1.25 hours

2700 mAh dual-cell (P/N 069429)

2.5 hours

2400 mAh single-cell (P/N 073929)

5 hours

4800 mAh dual-cell (P/N 073930)

9 hours

Important Recommendations

  • Use only Intermec-labeled lithium-ion battery packs (P/N 069428, P/N 069429, P/N 073929, or P/N 073930) in the battery charger.
  • Charge the battery pack immediately before use or within a couple of days of use.
  • For maximum battery efficiency, the recommended temperature range when charging is 25°C (77°F).
  • While the charger is in use, it becomes warm. This is normal.
  • Remove the battery pack from the charger within 24 hours after charging is completed. The green status LED will be on.

Loading and Unloading a Battery Pack Into the Charger Align the battery pack with a battery slot on the charger (as shown in the illustration) and slide the battery pack down until it fits firmly in the charger. To unload a battery pack from the charger, simply pull it out of the battery slot. You can unload and use a battery pack before it has been fully charged.

  • Keep the battery and charger contacts clean and free of dust and dirt. Remove any accumulated debris using a non-metallic pointed object.
  • Do not let anything metallic come into contact with the battery charger contacts.

Battery slot (2 places) Status LEDs

  • Do not disassemble the charger. There are no user-serviceable parts in the charger.
  • Do not place the charger in locations that are extremely hot or cold, dusty or dirty, very humid, or subject to vibration.

241XI002.eps

Power supply jack

Interpreting the Status LEDs Each battery slot has two status LEDs that indicate the status of the battery pack in the slot. Status LED Descriptions Status LED

Description

Yellow

The battery pack is charging or cold.

Green

The battery pack is fully charged or over heated.

Off

The battery slot is empty or the charger is not plugged in.

Flashing Yellow

There has been a charge interrupt or timeout.

  • If any part of the charger appears worn or damaged, or if any difficulty arises while using the battery charger, unplug the battery charger immediately and contact your Intermec service representative.

Troubleshooting If the charger does not charge the battery pack or if the LEDs do not light, try the following solutions:

  • Make sure that the charger is plugged in to an electrical outlet and that the electrical outlet has power.
  • Clean the contacts on the charger and battery pack with a cotton swab and isopropyl alcohol.