Page 41

Installing the Access Point Chapter1

2

If you decide to configure the access point locally, you will need to configure it before you mount it. If you decide to configure the access point remotely using a Telnet session, first you will need to set the IP address locally. Or, you can enable the access point to request its IP address from a BOOTP server and supply the address of the server. Then, you can mount the access point and configure it.

Attaching an Antenna The 0110/0111/0115 Access Point is shipped with a standard directlyconnected antenna. Intermec sells several different antennas, including higher gain and directional antennas. Each of these antennas ships with installation and mounting instructions. For information on additional antenna options, contact your local Intermec representative. Caution Government regulatory agencies mandate that the antenna not be alterable. Therefore, the access point uses a custom antenna connector. Do not attempt to use a different antenna or you may damage the connector and the access point. Conseil Les agences responsables de la réglementation gouvernementale exigent que l’antenne ne soit pas modifiable. Par conséquent, le point d’accès est doté d’un connecteur d’antenne personnalisé. Ne pas essayer d’utiliser une antenne différente au risque d’endommager le connecteur et le point d’accès.

Caution Make sure all components with antennas are at least 10 feet (3 meters) apart when power is applied. Failure to comply could result in equipment damage. Conseil Assurez-vous que la distance entre tous les éléments avec antennes soit d'au moins dix pieds (3 mètres) avant de faire la connexion avec l'alimentation électrique, faute de quoi vous risquez d'endommager votre installation.

2-11

Page 42

0110/0111/0115 Access Point User’s Manual Chapter1

To install the antenna •

Using a clockwise motion, firmly screw the antenna onto the antenna connector on the side panel of the access point.

011XU.003

Mounting the Access Point The 0110/0111/0115 Access Point was designed to sit on a flat surface. Intermec offers accessories that let you place the access point in an environmental box, mount the access point to a cubicle, or mount it to a wall. For more information, see the instruction sheet that came with your box or bracket.

Connecting to the Wired Network You connect your 0110/0111 Access Point to the Ethernet network and you connect the 0115 Access Point to the token ring network.

Ethernet The 0110/0111 Access Point is connected to the Ethernet network using 10BaseT cabling or 10Base2 cabling.

Using 10BaseT Cabling The 10BaseT cable typically connects the access point to a 10BaseT hub or wiring rack. Use the same cable that would otherwise be plugged into a 10BaseT workstation on the Ethernet network. If you are using a good cable, on the side panel the green LED nearest the connector will light. Standard 10BaseT specifications apply to the 10BaseT interface of the access point. No segment can exceed 328 feet (100 meters).

2-12

Page 43

Installing the Access Point Chapter1

2

Using 10Base2 Cabling When using 10Base2 cabling with the access point, you must properly terminate the cable on each end. Standard 10Base2 specifications apply to the 10Base2 interface of the access point. Each coaxial cable segment can support up to 30 devices and the cable itself cannot exceed 607 feet (185 meters).

Token Ring The 0115 Access Point is connected to the token ring network using an STP cable or a UTP cable. Note: If the adapter cable does not connect the access point to the token ring network when the access point is powered on, you will need to perform an Open Token Ring Adapter from the Token Ring Configuration Menu. Otherwise, the access point will not work.

Unshielded Twisted Pair (UTP) Cabling The UTP cable is typically connected between the access point and a MAU. If you are using a good cable and the access point is in the ring, one of the LEDs (4 Mbps/16 Mbps) nearest the connector will light. Shielded Twisted Pair (STP) Cabling The STP cable is typically connected between the access point and a MAU. If you are using a good cable and the access point is in the ring, the one of the LEDs (4 Mbps/16 Mbps) nearest the connector will light.

Plugging in the Power Supply Attach the power supply in the cable into the 10-18 VDC port on the side panel of the access point and the other end into an AC power outlet. Since there is no On/Off switch, the access point turns on as soon as power is applied. The Power LED on the front panel lights.

2-13

Page 44

0110/0111/0115 Access Point User’s Manual Chapter1

Configuring the Access Point This section provides guidelines on setting up the 0110 Access Point so that you can configure it. For help on the configuration parameters, see Chapter 3, “Configuring the 0110/0111 Access Point” or Chapter 4, “Configuring the 0115 Access Point” or Chapter 5, “Using an SNMP Manager or a Web Browser.”

Guidelines for Configuring Intermec 2.4 GHz RF Devices •

All access points are masters.

•

All data collection devices that communicate with the access points are stations.

•

Each access point must have a unique channel/subchannel pair. If possible, each access point should have a unique channel. Use the subchannel parameter only when you have more than 15 access points (you have used all 15 channels) in the same coverage area.

•

All access points and data collection devices in the same roaming network must have the same domain and security ID. Security ID is an optional parameter.

•

For roaming networks, overlap the transmission ranges of the access points. Note: You can set up another roaming network in the same area by configuring another set of access points and data collection devices with a new domain and security ID.

2-14

•

To get roaming to occur across routers, use a roaming protocol like Mobile IP or Mobile IPX.

•

Roaming will not occur between 0115 Access Points and 0110/0111 Access Points.

Page 45

Installing the Access Point Chapter1

2

Configuring the Access Point Locally (Out-of-Band) To configure the access point locally, you need to use a null modem cable to connect the access point to an empty serial port on your terminal or PC. This RS-232 cable must have a 9-pin socket connector to connect to the DB-9 serial port on the access point on one side and whatever your terminal or PC requires on the other side. Intermec offers a 9F to 25M null modem 3-wire RS232 cable (P/N 047569). If you choose to configure the access point using a PC, the PC must have a terminal emulation program running. Note: If you use a terminal emulation program that has the option to check for the CD signal before establishing a connection, configure the program to ignore CD. Or, verify that your null modem cable is a full handshake cable and pulls CD high. Intermec offers a JANUS Interlnk/Intrsvr cable (P/N 059167). To locally configure your access point 1. Unplug the access point. The Power LED is not lit. 2. Use the null modem cable to connect the serial port on the side panel of the access point to an empty serial port on your terminal or your PC. 3. Configure the terminal or terminal emulation program for a baud rate of 9600 bps, no parity, 8 data bits, and 1 stop bit. If you are using a terminal emulation program, choose TTY as the terminal type. 4. Plug in the access point. The Power LED lights. While the access point is booting, messages appear on the your terminal or your PC screen. When the access point is done booting, an “Initialization Complete” message appears. 5. On the terminal or PC, press Enter. You will enter the Main Menu. For help, see Chapter 3, “Configuring the 0110/0111 Access Point” or Chapter 4, “Configuring the 0115 Access Point.”

Configuring the Access Point Remotely (In-Band) Through a Telnet Session To configure the access point remotely through a Telnet session across the wired network, you must first set the access point IP address locally. Or, you can enable the access point to request its IP address from a BOOTP server and supply the address of the server. To set the IP address locally, see the previous procedure, “Configuring the Access Point Locally (Out-of-Band).” The access point does not ship with a default IP address.

2-15

Page 46

0110/0111/0115 Access Point User’s Manual Chapter1

To configure the access point remotely through a Telnet session 1. From a terminal or a PC that is running a Telnet (TCP/IP) client on the wired network, open a Telnet session on the access point. 2. If you enabled the feature that limits Telnet access by using a password (in the TCP/IP Configuration Menu), you are prompted for a password. Enter the password. You will enter the Main Menu. For help, see Chapter 3, “Configuring the 0110/0111 Access Point” or Chapter 4, “Configuring the 0115 Access Point.”

Configuring the Access Point Remotely Using Modems To configure your access point using modems, you need to connect one modem to your terminal or your PC and you need to use a straight-through cable to connect another modem to the access point. To configure the access point using modems 1. Attach a modem to your terminal or your PC. 2. Using the terminal or terminal emulation program, configure the modem to communicate at a baud rate of 9600 bps. 3. From the terminal or terminal emulation program, send these commands to the modem: ATS0=1

(Auto-answer after 1 ring)

AT&D0

(Ignore DTR)

ATE0

(No local echo)

ATQ1

(Suppress result codes)

AT&W0

(Store configuration in non-volatile memory)

4. Attach a modem using a straight-through cable to your access point. 5. From the modem connected to your terminal or PC, dial the phone number of the modem connected to the access point. 6. After the access point’s modem has answered, press Enter. You will see the Main Menu. For help, see Chapter 3, “Configuring the 0110/0111 Access Point” or Chapter 4, “Configuring the 0115 Access Point.”

2-16

Page 47

Installing the Access Point Chapter1

2

Configuring the Access Point Remotely Using an SNMP Manager 1. From an SNMP manager on your wired network, open an SNMP session on the access point. 2. Modify the access point parameters. For help, see Chapter 5, “Using an SNMP Manager or a Web Browser.”

Configuring the Access Point Remotely Using a Web Browser 1. Start a supported web browser on your PC. This PC must be connected to the network either using a wired or wireless connection. 2. Replace the URL path with the IP address of the access point. The browser displays the Intermec screen for the Access Point Web Manager. 3. If you set a browser user name and a browser user password in the TCP/IP Configuration Menu, you need to enter them before you can enter the Web Manager. 4. Modify the access point parameters. For help, see Chapter 5, “Using an SNMP Manager or a Web Browser.”

2-17

Page 48

0110/0111/0115 Access Point User’s Manual Chapter1

Dumping the Configuration to Screen When you are finished configuring the 0110/0111/0115 Access Point, you may want to see all of your current parameter settings on the same screen. Also, if you are having problems with your access point, Intermec Technical Support may ask you to use a screen capture program to create a snapshot of this screen and print it out for troubleshooting purposes. To dump the configuration to screen 1. From the Main Menu, at the prompt type 1 to enter the Configuration Menu and press Enter. 2. From the Configuration Menu, type 9 to dump the configuration to screen and press Enter.

The configuration parameters appear on the screen. The information may be presented page by page. Press any key to continue scrolling through the information.

2-18

Page 49

Installing the Access Point Chapter1

2

Resetting the Access Point This section explains how to reset the 0110/0111/0115 Access Point. Certain parameters, such as TCP/IP parameters, do not take effect until you reset the access point. To reset the access point 1. From the Main Menu, type 6 and press Enter. 2. Type 1 to confirm that you want to reset the access point and press Enter. If you are communicating with the access point through a Telnet session, your connection is terminated and the access point is reset. Note: You can also reset the radio on the access point without resetting the entire unit. For help, see “Using the Radio Configuration Menu” in Chapter 3.

Restoring the Access Point to the Default Settings Note: You can only restore the factory default settings if your access point is connected locally using a null modem cable to a terminal or a PC. To restore the access point to factory defaults 1. Connect the access point to your terminal or PC using a null modem cable and start the Main Menu. For help see “Configuring the Access Point Locally (Out-of-Band)” earlier in this chapter. 2. From the Main Menu, type 1 and press Enter. 3. From the Configuration Menu, type 8 to restore the access point to factory default settings and press Enter. 4. Reset the access point for the parameters to take effect. For help, see “Resetting the Access Point” in the previous section.

2-19

Page 50

Chapter1