For the Intermec 0110 and Intermec 0111

Page 111

Maintaining and Troubleshooting the Access Point Chapter6

6

Radio Status Menu (Ethernet and Token Ring) The current 0110/0111/0115 Access Point radio parameters appear in the Radio Status Menu. Parameter Name

Description

Current Channel

The channel the access point is using to communicate with its data collection devices.

Current Subchannel

The subchannel the access point is using to communicate with its data collection devices.

Current Domain

The domain all access points and data collection devices are using to communicate.

Current Master Name

A meaningful name for the access point.

Radio traffic level

This value may cause an SNMP trap.

Radio broadcast level

This value may cause an SNMP trap.

Last unauthorized address

Shows the MAC address of the last data collection device that tried to attach to the Ethernet network through this access point, but was prevented because of the authorization table.

Radio ROM version

The radio ROM version of this access point.

Reset required for reconfiguration

Set to true if there is a parameter pending that will not take effect until the access point or radio is reset.

Number of radio stations connected

The number of the current data collection devices configured as stations that are synchronized to this access point and have communicated within a specified time period (Aging Period parameter).

Aging period

This parameter is used with the Number of Radio Stations Connected parameter.

Bridge Status Menu (Ethernet and Token Ring) The MAC address of the 0110/0111/0115 Access Point is the bridge address in the Bridge Status Menu.

6-9

Page 112

0110/0111/0115 Access Point User’s Manual Chapter6

Forwarding Database Table (Ethernet and Token Ring) The 0110/0111/0115 Access Point is a learning bridge. After watching the packets on the network, the access point builds a database table of nodes located on either side (wired or wireless) of it. Use this menu option to view the forwarding database table. This table can hold a maximum of 2048 entries. If the Fixed Nodes filter is turned on, this table will only contain MAC addresses of data collection devices, which will change as those nodes roam.

Example

Token Ring Status Menu The current 0115 Access Point token ring parameters appear in the Token Ring Status Menu.

TCP/IP Status Menu (Token Ring) The current 0115 Access Point TCP/IP parameters appear in the TCP/IP Status Menu.

6-10

Parameter Name

Description

Current IP Address

The IP address of the access point.

Current Subnet Mask

The subnet mask of the token ring network that the access point is connected to.

Current Default Gateway Address

The IP address of the gateway that will route the packets to the proper destination if you are sending packets to an IP host or node on another IP subnet.

Page 113

Maintaining and Troubleshooting the Access Point Chapter6

6

Source Route Table (Token Ring) When the 0115 Access Point is configured for Multi-Ring SR/TB mode or Single-Ring SR/TB mode, this table shows the source routes that it has leared from each token ring station. In Multi-Ring SR/TB mode, the source route includes the radio ring number and the bridge number as part of the RIF.

Increasing Wireless Network Performance This section provides you with ideas on how to increase performance and network satisfaction on a wireless network.

Microwave Ovens Microwave ovens operate in the same frequency band as the access point. Therefore, if you use a microwave within range of your Intermec 2.4 GHz RF network, you may notice network performance degradation. However, both your microwave and your 2.4 GHz RF network will continue to function.

Transmission Range Every environment is unique with different obstacles, barriers, materials, etc. Therefore, it is difficult to determine the exact range that will be achieved with testing. Intermec highly recommends that you allow an Intermec-certified RF specialist to perform a site survey before you install a wireless network. For more information on site surveys, contact your local Intermec representative. There are tools on the access point that were developed to aid in the site survey process, but they are not adequate enough to perform a complete site survey. For help using these tools, see Appendix B, “Using the Site Survey Tools and the Antenna Pointing Tool.” Radio signals may reflect off of some obstacles or be absorbed by others, depending on their construction. For example, with two radios you may achieve up to 1000 feet (305 meters) in open space outdoors if the two antennas are line of sight, meaning there are no obstacles between them. However, the same two units may only achieve up to 500 feet (152 meters) of range when the RF signal has to travel through items, such as cubicles. If there are office walls to penetrate, the signal range may decrease to 300 feet (91 meters). If you are interested in antenna options, contact your Intermec representative about antenna kits.

6-11

Page 114

0110/0111/0115 Access Point User’s Manual Chapter6

Proper antenna placement can help improve range. Here are some guidelines: •

Place the antenna in a vertical position. It can be mounted upside down from the ceiling or a beam.

•

Place the antenna as high as possible. In an office environment, try to place it above cubicle walls.

•

Do not place a sheet of metal (like a filing cabinet) between two antennas.

•

Two antennas that are communicating should be in the same plane. For example, do not place one antenna on its side and place the other one standing upright.

How to Obtain Help With Your Installation The 0110/0111/0115 Access Point is designed to be very easy to install and operate. If you are having trouble with your installation, make sure you can answer these questions, before calling Intermec Technical Support: •

What kind of network are you using?

•

What were you doing when the error occurred?

•

What error message did you see?

•

Can you reproduce the problem?

•

What version of the access point firmware are you using?

Diagnostics Menu There are diagnostic tools built into the 0110/0111/0115 Access Point that will help you or Intermec Technical Support in solving problems. If you call Intermec Technical Support, they may ask you to look at some of the parameters in the Diagnostics Menu. To access the Diagnostics Menu •

6-12

From the Main Menu, type 5 and press Enter. The Diagnostics Menu appears.

Page 115

Maintaining and Troubleshooting the Access Point Chapter6

6

Diagnostics Menu Selection ---------

Description -----------

Current Value -------------

1

Radio Diagnostics Menu

2

Technical Support Parameters

3

Boot ROM Version

4

Flash Code Version

5

Ping IP Hosts

6

Discover APs

7

Display Wireless Network Tree

Enabled

Enter a selection number or <ESC> for previous menu ->

Parameter Name

Description

Radio Diagnostics Menu

You can run the site survey tools, run the antenna pointing tool, and read the ROM version of the radio contained inside the access point. For help, see Appendix B, “Using the Site Survey Tools and the Antenna Pointing Tool.”

Technical support parameters

You can enable or disable this feature.

Boot ROM version

You can use this auto-boot feature to initialize the Ethernet, token ring and radio cards and start the SNMP agent, if you are using one. If the auto-boot is successful, you receive the message, “Initialization Complete.” You can only use this feature if your access point is connected locally using a null modem cable to a terminal or PC.

Flash code version

You can find out the software version of this access point.

Ping IP hosts

You can ping another IP host on the network. This feature may be useful in isolating which side of the access point (wired or wireless) is not working properly. To use this feature, you need to have the host’s IP address.

6-13

Page 116

0110/0111/0115 Access Point User’s Manual Chapter6

Parameter Name

Description

Discover APs

You can use this access point to look for all other access points on the network. The access point returns a table containing all the MAC addresses, IP addresses, domains, channels, subchannels, and master names it finds.

Display wireless network tree

You can display the tree of all of the access points that this access point discovers along with their relationship to one another, i.e., who is synchronized to whom. The access point from which the tree is being built is listed with asterisks (***) next to its name.

Commonly Asked Technical Support Questions

6-14

Problem/Symptom/Question

Possible Solution/Answer

Is the access point fully booted?

The Power LED changes from orange to steady green.

The Power LED is steady red.

You may have a hardware problem with your access point. 1.

Unplug the access point and then plug it back in to cycle the power. Verify the Power LED is red.

2.

Call Intermec Technical Support.

I cannot configure the access point locally using the serial port.

1.

Verify you are using a null modem cable to connect the access point to your terminal or PC.

2.

Verify the terminal or PC is set to 9600 N81.

I cannot ping or Telnet to my new access point.

The access point does not come with a default IP address. Before you can remotely connect to the access point, you must locally set an IP address . Or, you can configure the access point to get an IP address from a BOOTP server.

Page 117

Maintaining and Troubleshooting the Access Point Chapter6

6

Problem/Symptom/Question

Possible Solution/Answer

(Ethernet) The data collection device (station) cannot connect to the network.

You may not be in range of the access point (master).

(Token ring) The data collection device (station) cannot connect to the network.

1.

Use one of the site survey tools to verify that you have a wireless connection.

2.

Check the Ethernet Statistics Menu to verify there is Ethernet traffic that the access point can detect.

3.

If you are using a 10BaseT cable, verify that the 10BaseT LED on the side panel is lit. If it is lit, the cable is functional.

4.

Verify that the access point is not filtering out the type of traffic you are trying to pass through it.

You may not be in range of the access point (master). 1.

Use one of the site survey tools to verify that you have a wireless connection.

2.

Check the Token Ring Statistics Menu to verify there is token ring traffic that the access point can detect.

3.

If you are using a UTP cable, verify that the LED nearest the connector on the side panel is lit. If it is lit, the cable is functional.

4.

Verify the access point is not filtering out the type of traffic you are trying to pass through it.

The data collection device (station) cannot synch to the access point (master).

Verify that the data collection device and access point have the same domain and security ID.

How can I tell which data collection devices are synchronized to my access point?

Use the Status Menu to view the Forwarding Database Table. Data collection devices that are synchronized to the access point are listed.

Are the wrong filters set?

Use the Configuration Menu to turn on one of the filters. Then, check the Filter Statistics Menu. If the count is increasing on the filter you set, that kind of traffic is on the network. If data collection devices cannot attach to the network after setting this filter, turn that filter off.

Access points must be configured as masters and data collection devices must be configured as stations.

6-15

Page 118

0110/0111/0115 Access Point User’s Manual Chapter6

6-16

Problem/Symptom/Question

Possible Solution/Answer

The throughput seems slow.

1.

Verify your antennas are well-placed, not behind metal, and there are not too many obstacles. See “Increasing Wireless Network Performance” earlier in this chapter.

2.

If you move the antenna closer to the data collection device and throughput increases, you may want to add a second access point and implement roaming.

3.

You may be able to set filters to filter out Ethernet traffic from the wireless side of the network.

Page 119

Chapter1

A Specifications

Page 120

Chapter1