Spec sheet · HP
HP HBCS-A200, HBCS-A207, HBCS-A300, HBCS-A305, HBCS-A307+, HBCS-A308 and HBCS-A500 Spec Sheet
Spec sheet4 pagesPDF 175 KB
All 4 pages are below, each with its text.
Names · 5 models
The models it names
Filed with · 2 models
Also filed with these models on the old site
From the sheet · read page by page
Key facts from this sheet
Each line names its page in the PDF.
Hewlett-Packard technical data sheet for the HBCS-A000 series low current digital bar code wands, hand-held pen scanners built for battery powered equipment. It covers the whole series, with a selection guide of part numbers by resolution, LED color, switch and connector, plus electrical specifications, how the output works, shielding and connector details.
- Device
- Low current digital bar code wand (hand-held pen scanner) for battery powered applications p. 1
- Output
- Open collector transistor; TTL compatible with a pull-up resistor; black bar gives logic high p. 3
- Scan angle
- 0° to 45° typical p. 1
- Case
- Rugged polycarbonate p. 1
- Shield
- Case, cable and connector shield, terminated to logic ground (preferably also earth ground) p. 3
- Ambient light
- High ambient light rejection; works in direct sunlight p. 1
- Series LED options
- Visible red (655 nm) or infrared (820 nm) p. 1
- Series resolutions
- 0.33 mm (0.013 in.), 0.19 mm (0.0075 in.) or 0.13 mm (0.005 in.) p. 1
- Series switch options
- Switched or unswitched p. 1
- Series connectors
- 5-pin DIN, 9-pin D-Sub, or no connector (stripped and tinned leads) p. 1
- Idle output
- Settles to logic low, typically in under 1 second, when nothing is scanned p. 3
- Preferred tilt
- 10° to 30° p. 4
- Boxed option
- Order Option #A01 for an individually boxed wand p. 1
What this sheet walks you through
- Choosing a part number by resolution, LED, switch and connector p. 1
- Electrical specifications and absolute maximum ratings p. 2
- How the wand output and shield work p. 3
- Wand dimensions, connector layout and preferred hookup p. 4
Good to know
- If bought with stripped and tinned wires, or with the connector removed, the ground and shield wires must be joined for proper operation. p. 4
- A wand bought without a connector counts as a subassembly and its FCC identification number no longer applies. p. 3
- Shield and ground are tied together in the connector. p. 4
Questions this sheet answers
What kind of output does the HP HBCS-A200 wand give?
A digital open collector output that becomes TTL compatible with a pull-up resistor; a black bar reads as logic high. p. 3
What connectors are HBCS-A000 series wands sold with?
A 5-pin DIN, a 9-pin D-Sub, or no connector with stripped and tinned leads. p. 1
Do HP bar code wands come in infrared?
Yes, the series is offered in visible red (655 nm) and infrared (820 nm) versions. p. 1
At what angle should the HBCS wand be held?
The preferred tilt angle shown is 10° to 30°. p. 4
The file
Size and text
Every page · 4
Read it here
Each page as it is printed, and its words beside it, so a phone can search and copy them.
Page1of 4
Open in the PDF
The text of page 1, from the PDF itself
H
Low Current Digital Bar Code Wand Technical Data HBCS-A000 Series
Features
Description
- Rugged Polycarbonate Case, Switched or Unswitched
- Ultra Low Continuous Current Draw
- Available in 3 Resolutions to Meet a Variety of Scanning Needs
- High Ambient Light Rejection–Operates in Direct Sunlight
- Visible Red (655 nm) and Infrared (820 nm) Versions Available
- Scan Angle: 0° to 45° Typical
- Manufacturing: ISO 9002 Certified
The HBCS-A000 series low current digital wands are hand held scanners optimized to provide excellent scanning of all common bar code formats. The patented low current, high ambient light rejection circuitry is packaged in a rugged polycarbonate case. Available in three resolutions, these wands are capable of reading a wide range of bar code printing. Visible red and infrared versions are available for reading a wide range of print types and colors. The wands are available with or without a switch to control the wand operation.
Applications The HBCS-A000 series wands are highly effective alternatives to keyboard data entry. These devices are especially designed for battery powered applications where low power drain is a primary concern. In addition to their low current draw, these wands are also designed to work in high ambient light, such as outdoors or near windows.
Selection Guide Wand Type Typical Resolution LED Wavelength 5-Pin DIN Connector 9-Pin D-Sub Connector No connector: Strip and Tin Leads Individually Boxed Wand
Switched 0.33 mm 0.19 mm (0.013 in.) (0.0075 in.) 655 nm HBCS-A000* HBCS-A200
Unswitched 0.13 mm 0.33 mm 0.19 mm 0.13 mm (0.005 in.) (0.013 in.) (0.0075 in.) (0.005 in.) 820 nm 655 nm 820 nm HBCS-A400* HBCS-A100* HBCS-A300 HBCS-A500*
HBCS-A008* HBCS-A208* HBCS-A408* HBCS-A108* HBCS-A308* HBCS-A508* HBCS-A007* HBCS-A207* HBCS-A407* HBCS-A107* HBCS-A307* HBCS-A507* Order Option #A01 with the above referenced part number. The wand is shipped in a “kraft” box, including an HBCS-A000 series data sheet.
*Note: Build to order product only. Minimum stock is available for engineering evaluation purchases.
5965-1520E
4-71
Page2of 4
Open in the PDF
The text of page 2, from the PDF itself
Specifications (TA = 25°C Typical) Parameter Scan Velocity Edge Contrast Supply Voltage (VCC) Supply Ripple Temperature Ambient Light
Minimum 7.6 (3) 45 4.5
Maximum 127 (50) 5.5 100 +65 100,000
-20
Units cm/sec (in/sec) % V mVpp °C lux
Notes 1
Absolute Maximum Ratings Parameter Storage Temperature Operating Temperature Supply Voltage Output Transistor Power Output Collector Voltage
Minimum -40 -20 -0.5
Maximum +75 +65 +6 150 +20
-0.5
Units °C °C V mW V
Electrical Characteristics (TA = 25°C) Parameter Supply Current High Level Output Current Low Level Output Voltage Output Rise Time Output Fall Time Switch Bounce ESD Immunity ESD Isolation Unswitched Wands ESD Isolation–Switched Wands Wake-Up Time
Min. 2.5Typ. 3.53.4 1.2 0.5 25 15 8 50
Max. 5.0 1.0 0.4 20 20 5.0
200
Units mA A V µs µs ms kV kV kV ms
Conditions VS = 5.0 V VOH = 2.4 V IOL = 16 mA
Notes 2
3 3 4 5 5 5 6
Notes: 1. Contrast is defined as RW - RB where RW is the reflectance of the white spaces and RB is the reflectance of the black bars, measured at the emitter wavelength (655 nm or 820 nm). Contrast is related to PCS by PCS = (RW - RB)/RW or RW - RB = PCS * RW. 2. Not including the pull-up resistor current. 3. 10% to 90% transitions. 4. Switch bounce causes a series of sub millisecond pulses to appear on the output. 5. Shield must be properly terminated. The human body is modelled by discharging a 300 pF capacitor through a 500 Ω resistor. No damage to the wand will occur at the specified discharge level. The energy will be passed through the shield to the host device. 6. After this time, the wand is operational.
4-72
Page3of 4
Open in the PDF
The text of page 3, from the PDF itself
Electrical Operation The HBCS-A000 series digital bar code wands consist of a precision optical sensor and an electronic circuit that creates a digital output of the bar code pattern. The open collector transistor requires only a pull-up resistor to provide a TTL compatible output. A non-reflecting black bar results in a logic high (1) level output, while a reflecting white space will cause a logic low (0) level output. The initial state will be indeterminate. However, if no bar code is scanned, after a short period, (typically less than 1 second), the wand will assume a logic low state. The wands provide a case, cable and connector shield which must be terminated to logic ground, or preferably, to both logic ground and earth ground. The shield is connected to the metal housing of the 5 pin DIN connector.
Certification FCC Certification (US Only) Hewlett-Packard products have received FCC certification for its standard configuration only. Any customer purchasing the product with stripped and tinned leads or a connector without adequate shielding has the responsibility to comply with FCC regulations. Moreover, if the Hewlett-Packard Low Current Bar Code Wands are purchased without a connector, the product becomes defined as a
subassembly and the FCC identification number no longer applies. Hewlett-Packard assumes no responsibility or liability for users of the Hewlett Packard Low Current Digital Bar Code Wands without connectors that fail to comply with FCC regulations. This equipment complies with Part 15, Class B, of the FCC Rules. Operation is subject to the following two conditions: l) This equipment may not cause harmful interference, 2) This equipment must accept any interference that may cause undesired operation.
Model HBCS-A000 through -A099 HBCS-A100 through -A199 HBCS-A200 through -A299 HBCS-A300 through -A399 HBCS-A400 through -A499 HBCS-A500 through -A599
Warranty and Service Hewlett-Packard Low Current Digital Bar Code Wands are warranted for a period of one year after purchase covering defects in material and workmanship. Hewlett-Packard will repair, or at its option, replace products that prove to be defective in material or workmanship under proper use during the warranty period. NO OTHER WARRANTIES ARE EXPRESSED OR IMPLIED, INCLUDING BUT NOT LIMITED TO THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE. HEWLETT-PACKARD FCC Identification FCC ID: B948JAHBCS-A000 HEWLETT-PACKARD FCC ID: B948JAHBCS-A000 HEWLETT-PACKARD FCC ID: B948JAHBCS-A200 HEWLETT-PACKARD FCC ID: B948JAHBCS-A300 HEWLETT-PACKARD FCC ID: B948JAHBCS-A400 HEWLETT-PACKARD FCC ID: B948JAHBCS-A500 HEWLETT-PACKARD IS NOT LIABLE FOR CONSEQUENTIAL DAMAGES.
The CE Mark demonstrates compliance with EC directives on EMC.
For additional warranty or service information please contact your local Hewlett-Packard sales representative or authorized distributor.
VCCI Registration: Pending
4-73
Page4of 4
Open in the PDF
The text of page 4, from the PDF itself
Wand Dimensions and Connector Configurations 23 (0.9)
SWITCH H3.4 (0.135)19 (0.8)160 (6.3)9561300 (12)200 (8)480 (19)HBCS AX08HBCS AX004 53
PRODUCT IDENTIFICATION LABEL
2 1
ALL DIMENSIONS IN MILLIMETERS (INCHES)
Function VCC Output Ground Shield
HBCS-AX00 HBCS-AX08 Wire Color 1 9 Red 2 2 White 3 7 Black Shell 8 Braid All other pins are N/C
Shield and ground are tied together in the connector. Note: If the part is purchased with stripped and tinned wires, or if the connector is removed, the ground and shield wires must be connected together for proper operation.
Preferred Orientation
Preferred Electrical Connection VCC
VCC
TILT ANGLE 10° TO 30° 4.7 kΩ
10 µFOUTPUT OUTPUTGROUND HGROUND SHIELD4-74