Page 8

Maintenance The SV Series is designed to provide maintenance free operation through its life and contains no moving parts that require maintenance. Cleaning The output window should be kept clean by wiping it with a slightly dampened, soft cloth. Dampen with water or a screen cleaner. Customer Support Offices

Printronix, Inc. 14600 Myford Road Irvine, CA 92606 PHONE +1 (714) 368-2781 FAX +1 (714) 368-2354

WARRANTY General Warranty RJS warrants the SV Series to be free from defects in material and workmanship for a period of 1 year, under normal use and service, from the date of shipment from RJS’ factory location. The liability of RJS under this warranty is limited to repairing or replacing the defective part and/or unit. RJS may optionally choose to issue credit for any unit returned during the warranty period. You must promptly notify RJS of any defect in order to receive the full protection of this warranty. Warranty Limitations The warranty set forth above is exclusive and no other warranty, whether written or oral is expressed or implied. RJS specifically disclaims the implied warranties of merchantability and fitness for a particular purpose. RJS is not liable for indirect or consequential damages incurred due to a warranted product’s failure that brings about increased costs of doing business. Service During the Warranty Period If your SV unit should fail during the warranty period, contact RJS or its authorized representative immediately upon discovery of the defect. RJS’ Customer Service Department will provide you with a Return Authorization Number (RMA number). You will be asked to ship the product in its original packing, freight prepaid, with the RMA number visibly written on the outside of the carton to RJS’ factory location. Be sure to include any samples or printouts or other information that will help us to understand the problem. Your repair will be given priority treatment, or your unit may be replaced at RJS’ option. The repaired item will be returned UPS/RPS ground, freight prepaid. At your request RJS will ship express or overnight if you need premium service and agree to pay the additional cost.

5

Page 9

INTRODUCTION The RJS SV Series of Scanner/Verifiers is designed to be a universal system component that can analyze linear bar code print quality, check encoded data and detect system failures. In its basic mode of operation, an SV unit acts similar to a normal fixed position scanner by automatically decoding bar codes as they pass through its laser beam. Additional capabilities such as performing bar code verification and operating in synchronous modes make the SV Series unique. The SV Series combines state-of-the-art digital signal processor (DSP) technology, a proprietary highspeed moving beam laser scanner with unique analog output capability and flexible I/O and communications capability. This powerful architecture enables an SV unit to be an economical Quality Assurance tool for practically any bar code printing, applying or conveying system. The SV Series performs practically every accepted method of bar code verification – ANSI method, traditional method, encoded data format checks and laser scanning type analyses. These wide-ranging analysis parameters can be used to measure bar code quality and detect failure mechanisms for any print technology. Bar code quality and encoded data information can be reported through the serial communications port for each code analyzed, therefore accountability for all bar codes printed is possible. An SV Unit’s I/O consists of five programmable output ports, two programmable display LED’s and a sync input (with two interface circuit choices.) This allows the unit to be used as a local controller for pausing printers, activating lights, gating conveyors, etc. The SV Series is available in different models. All models operate identically, except the scanner parameters such as scans per second and focus distance are different. Below is a matrix describing standard available models.

SV Series Model Specifications* Analyses/sec Scan Width Focus Distance X dim (min)

SV100 100 6” (152mm) 8” (203 mm) .0067” (.17mm)

SV100HD 100 4.5” (114mm) 6” (152mm) .005” (.127mm)

SV100C 100 10.5” (267mm) 15” (381mm) .013” (.33mm)

SV200-1 200 2.5” (63.5mm) 8” (203mm) .0067” (.17mm)

SV200-2 200 1.75” (44mm) 6” (152mm) .005” (.127mm)

* Contact RJS Technical Support for information on custom and other models The recommended setup tool for the SV Series is RJS ScanVision Windows based software. This program makes SV setup simple via menus plus it offers real time monitoring of bar codes being analyzed. This program is available at no charge from RJS and authorized RJS re-sellers. ScanVision can be used to program the SV Series via serial communication using SV Download language. The language is described in this Operator’s Guide.

LASER BEAM The laser beam may be on at any time the Power/Sync LED is illuminated.

RESET BUTTON The Reset button is multifunctional.

Turn Off Laser Beam The laser beam may be turned off (therefore turning off the SV unit’s operation) by holding down the Reset button for a few seconds until the beam turns off. Pressing the Reset button again will begin normal operation.

6

Page 10

Note: there are some modes of operation when the laser beam is on only during specific scanning times (see the ~SA Command in the SV Command Language Section.) Using the Reset Button for turning off the system is not recommended in these modes.

Perform Calibration The reset button is used in the calibration procedures. See the Calibration Section for details.

Reset Ports Pressing the Reset button will reset ports to their inactive states. This is useful in systems where the SV unit is holding a printer in PAUSE mode and the user desires to clear the pause condition. See the Output Ports Section for details.

I/O CONNECTOR The I/O connector is used for all power and field interconnections. The connector is a DB 15 male. Pin-outs are shown below: 1 Isolated synchronization input (+) 2 Isolated synchronization input (-) 3 GND 4 Switch synchronization input 5 Output 1 6 Output 2 7 Output 3 8 Output 4 9 Reserved 10 Reserved 11 GND 12 +5 VDC power in 13 Power GND 14 GND 15 Output 5

+ 5 VDC Power Input The SV Series requires + 5 Volts DC, +/- 0.25 Volt. Maximum current consumption is 1 amp. The voltage input must be connected to pin 12 and the ground input should be connected to pin 13 on the I/O connector. The alternate ground pins (3, 11 and 14) may be used for power ground or for connecting the ground(s) of an external device(s) (such as presence sensors) that may be powered from a different source than the verifier power input.

Sync Inputs Utilizing a sync signal is recommended for all applications using hardware (as opposed to communication) interfaces. (Also see Operation Modes Section.) A sync signal is used to synchronize the SV Series to an object, label, etc. that contains the bar code(s) being analyzed as it passes through the laser beam. The SV Series should be programmed for the number of bar codes expected per sync interval. This ensures a robust system that can report all undetectable bar codes due to printer failure, missing labels, etc. along with quality and data information on bar codes that are fully or partially decoded. Two hardware sync inputs are available. Pin 4 is designed to be used with ttl or open collector inputs. Pins 1 and 2 form a ground isolated input designed to be used with systems that need separate grounds than the verifier and/or output a higher voltage level than ttl. Sync inputs are also available via serial communications.

7

Page 11

Hardware sync operation is very flexible due to programmable options. Two sync modes – edge and envelope – are available. Signal input polarity is also user programmable. Please see the Operation Modes Section for more information on use of these sync modes.

Edge Sync Mode This mode senses a signal transition level of a sync signal as shown in Figure S1.

Sync sensed here

Figure S1 – Edge Sync Figure S1 shows the sync operation of an SV unit programmed to sense the rising edge of a sync signal in edge mode. Each time a rising edge is sensed, the SV unit does the following: 1. It verifies that at least the number of bar codes expected (programmed) since receiving the last sync input have been fully decoded. If not, a No Read condition is internally set for possible reporting through communication or output activation. 2. It begins a new interval, counting the bar codes analyzed until the next sync input is received. 3. A Serial communication report is transmitted and an output port is updated per its programmed function each time a bar code is analyzed.

Envelope Sync Mode This mode senses two (leading and trailing) transitions of the sync signal to determine when to begin and end the period for determining missing bar codes as shown in Figure S2 below. Sync period starts here

Sync period ends here

Figure S2 – Envelope Sync Figure S2 shows the sync operation of an SV unit programmed to sense the rising voltage edge as the start of a sync period. The SV unit operates in this mode as follows: 1. Upon receipt of the starting edge of a sync signal, the unit begins counting the bar codes being scanned and analyzed. 2. A Serial communication report is transmitted and an output port is updated per its programmed function each time a bar code is analyzed. 3. Counting ceases upon receipt of the trailing edge of a sync signal. The SV Series determines that at least the number of bar codes expected (programmed) during the sync period have been fully decoded. If not, an internal No Read condition is set for possible reporting through communication or output activation. 4. The SV unit then waits for the next leading edge of a sync signal to begin counting codes being scanned and analyzed.

8