IMAGETEAM 4410/4710 2D Series Hand Held Imager User's Guide: Maintenance & Troubleshooting
Pages 193 to 196 of 216, from IMAGETEAM 4410/4710 2D Series Hand Held Imager User's Guide
The original document is the PDF (2.6 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the HHP IT4410 and HHP IT4710
Page 193
11 Maintenance & Troubleshooting Repairs Repairs and/or upgrades are not to be performed on this product. These services are to be performed only by an authorized service center. See page 121 for further information.
Maintenance The IMAGETEAM 4410/IT4710 Imager provides reliable and efficient operation with a minimum of care. Although specific maintenance is not required, the following periodic checks ensure dependable Imager operation:
Cleaning the Imager’s Window Reading performance may degrade if the Imager’s window is not clean. If the window is visibly dirty, or if the Imager isn’t operating well, clean the window with a soft cloth or facial tissue dampened with water (or a mild detergent- water solution). If a detergent solution is used, rinse with a clean tissue dampened with water only. The Imager’s housing may also be cleaned the same way.
!
Caution:
Do not submerge the Imager in water. The Imager’s housing is not water-tight. Do not use abrasive wipers or tissues on the Imager’s window abrasive wipers may scratch the window. Never use solvents (alcohol or acetone) on the housing or window - solvents may damage the finish or the window.
Inspecting Cords and Connectors Inspect the Imager’s interface cable and connector for wear or other signs of damage. A badly worn cable or damaged connector may interfere with Imager operation. Contact your distributor for information about cable replacement. Cable replacement instructions are on the next page.
11 - 1
Page 194
Examining the Imager’s Housing Routinely examine the Imager’s housing for signs of damage. A damaged housing may cause the internal components to move and may result in a malfunctioning Imager.
Replacing the Interface Cable The standard interface cable is attached to the Imager with an 10-pin modular connector. When properly seated, the connector is held in the Imager’s handle by a flexible retention tab. The cable is designed to be field replaceable. • Order replacement cables from or from an authorized distributor. • When ordering a replacement cable, specify the cable part number of the original interface cable.
To Replace the IT4410 Interface Cable: 1. Turn the power to the host system OFF. 2. Disconnect the Imager’s cable from the terminal or computer. 3. Locate the small hole on the side of the Imager’s handle near the base (cable release). 4. Straighten one end of a paper clip. 5. Insert the end of the paper clip into the small hole and press in. This depresses the retention tab, releasing the connector. Pull the connector out of the Imager’s handle while maintaining pressure on the paper clip. 6. Replace with the new cable. Insert the connector into the opening at the base of the Imager’s handle. Press firmly. The connector is “keyed” to go in only one way, and will click into place.
11 - 2
Cable Release
Page 195
To Replace the IT4710 Interface Cable: 1. Turn the power to the host system OFF. 2. Disconnect the Imager’s cable from the terminal or computer. 3. Insert a small, flat head screwdriver into the slot between the cable and the back end of the housing. 4. Press the screwdriver tip down to depress the retention tab, releasing the connector. 5. Pull the connector out of the Imager while maintaining pressure on the screwdriver.
Cable Release
6. Replace with the new cable. Insert the connector into the opening at the base of the Imager. Press firmly. The connector is “keyed” to go in only one way, and will click into place.
Troubleshooting The Imager automatically performs self-tests whenever you turn it on. If your Imager is not functioning properly, review the following Troubleshooting Guide to try to isolate the problem.
Troubleshooting Guide Is the power on? Are the illumination LEDs on? If the illumination LEDs in the Imager aren’t illuminated, check that: 1. The cable is connected properly. 2. The host system power is on (if external power isn’t used).
Is the Imager having trouble reading your symbols? If the Imager isn’t reading symbols well, check that the symbols: 1. Aren’t smeared, rough, scratched, or exhibiting voids. 2. Aren’t coated with frost or water droplets on the surface. 3. Are enabled in the Imager or in the decoder the Imager connects to.
11 - 3