Page 171
8 Visual Menu Visual Menu Introduction Visual Menu provides the ability to configure a scanning device by connecting the scanner to the com port of a PC. Visual Menu allows you to download upgrades to a scanner’s firmware, change programmed parameters, and create and print programming bar codes. Using Visual Menu, you can even set up the configuration for a scanner which is not attached to your PC. This enables one expert user to establish the configuration settings for all the devices your company uses, then save these configuration files for others. A configuration file can be e-mailed or, if you prefer, an expert user can create a bar code (or series of bar codes) which contains all the customized programming parameters, and mail or fax the bar code(s) to any location. Users in other locations can scan the bar code(s) to load in the customized parameters. To communicate with a scanner, Visual Menu requires that the PC have at least one available serial communication port and an RS-232 cable to connect the port to the device. A power supply, which plugs into the cable, is also required.
Visual Menu Operations The Visual Menu program performs the following operations: • Displays all configuration data, and saves the information to a file on your PC. • Configures the device to meet your specific requirements. Visual Menu has all the programming parameters which are available via programming bar codes in this User’s Guide. • Creates and prints a clone bar code which contains the program and configuration data from one device. This bar code can then be used to program additional devices with the same parameters. • Selects a device from a list, then performs offline or online file configuration for that device.
8-1
Page 172
Temporary Visual Menu Configuration For quick download communication configuration, scan the Visual Menu bar code to temporarily configure the scanner for Visual Menu settings.
Note: If you have a unit capable of keyboard wedge mode, scan the bar code below and the unit will communicate in RS-232 mode, allowing it to work with Visual Menu. To convert the scanner back to keyboard wedge communication, cycle the power.
Visual Menu
Installing Visual Menu from the Web 1. Access the Hand Held Products web site at www.handheld.com. 2. Click on the Quick Search text box and enter Visual Menu. 3. Click on Search Now. 4. Click on the entry for Visual Menu. 5. When prompted, select Save File, and save the files to the c:\windows\temp directory. 6. Once you have finished downloading the file, exit the web site. 7. Using Explorer, go to the c:\windows\temp file. 8. Double click on the Visualmenu.exe file. Follow the screen prompts to install the Visual Menu program. 9. To start Visual Menu, from the Start Menu click on Programs, Visual Menu, Visual Menu.
Note: If you wish, you can create a shortcut to the Visual Menu executable on your desktop.
8-2
Page 173
9 Interface Keys
Supported Interface Keys NUL SOH STX ETX EOT ENQ ACK BEL BS HT LF VT FF CR SO SI DLE DC1 DC2 DC3 DC4 NAK SYN ETB CAN EM SUB ESC FS GS RS US
00 01 02 03 04 05 06 07 08 09 0A 0B 0C 0D 0E 0F 10 11 12 13 14 15 16 17 18 19 1A 1B 1C 1D 1E 1F
IBM AT/XT and PS/2 Compatibles, WYSE PC/AT Reserved Enter (KP) Caps Lock ALT make ALT break
CTRL make CTRL break CR/Enter Reserved Tab Reserved Tab Delete CR/Enter Insert Escape F11 Home Print Back Space Back Tab F12 F1 F2 F3 F4 F5 F6 F7 F8 F9 F10
IBM XTs and Compatibles
IBM, DDC, Memorex Telex, Harris*
Reserved CR/Enter Caps Lock Reserved Reserved Reserved Reserved CR/Enter Reserved Tab Reserved Tab Delete CR/Enter Insert Escape Reserved Home Print Back Space Back Tab Reserved F1 F2 F3 F4 F5 F6 F7 F8 F9 F10
Reserved Enter F11 F12 F13 F14 F15 New Line F16 F17 F18 Tab/Field Forward Delete Field Exit/New Line Insert F19 Error Reset Home F20 Back Space Backfield/Back Tab F21 F1 F2 F3 F4 F5 F6 F7 F8 F9 F10
* IBM 3191/92, 3471/72, 3196/97, 3476/77, Telex (all models)
9-1
Page 174
Supported Interface Keys NUL SOH STX ETX EOT ENQ ACK BEL BS HT LF VT FF CR SO SI DLE DC1 DC2 DC3 DC4 NAK SYN ETB CAN EM SUB ESC FS GS RS US
00 01 02 03 04 05 06 07 08 09 0A 0B 0C 0D 0E 0F 10 11 12 13 14 15 16 17 18 19 1A 1B 1C 1D 1E 1F
IBM, Memorex Telex (102)* Reserved Enter F11 F12 F13
F14 F15 New Line F16 F17 F18 Tab/Field Forward Delete Field Exit Insert Clear Error Reset Home Print Back Space Back Tab F19 F1 F2 F3 F4 F5 F6 F7 F8 F9 F10
Memorex Telex (88)** Reserved Enter PF10 PF11 PF12 Reserved Reserved New Line Field Forward Field Forward Reserved Field Forward Delete New Line Insert Erase Error Reset
Reserved Print Back Space Back Field Reserved PF1 PF2 PF3 PF4 PF5 PF6 PF7 PF8 PF9 Home
* IBM 3196/97, 3476/77, 3191/92, 3471/72, Memorex Telex (all models) with 102 key keyboards ** Memorex Telex with 88 key keyboards
9-2
Page 175
Supported Interface Keys
Esprit 200, 400 ANSI
Esprit 200, 400 ASCII
Esprit 200, 400 PC
NUL SOH STX ETX EOT ENQ ACK BEL BS HT LF VT FF CR SO SI DLE DC1 DC2 DC3 DC4 NAK SYN ETB CAN EM SUB ESC FS GS RS US
Reserved New Line N/A N/A N/A N/A N/A New Line N/A Tab N/A Tab N/A New Line N/A Escape F11 Insert F13 Back Space Back Tab F12 F1 F2 F3 F4 F5 F6 F7 F8 F9 F10
Reserved New Line N/A N/A N/A N/A N/A New Line N/A Tab N/A Tab N/A New Line N/A Escape F11 Insert F13 Back Space Back Tab F12 F1 F2 F3 F4 F5 F6 F7 F8 F9 F10
Reserved New Line N/A N/A N/A N/A N/A New Line N/A Tab N/A Tab Delete New Line Insert Escape F11 Home Print Back Space Back Tab F12 F1 F2 F3 F4 F5 F6 F7 F8 F9 F10
00 01 02 03 04 05 06 07 08 09 0A 0B 0C 0D 0E 0F 10 11 12 13 14 15 16 17 18 19 1A 1B 1C 1D 1E 1F
9-3
Page 176