Page 141
Bills of Lading Demonstration Multiple linear bar codes may be replaced in a bill of lading/inventory application. In this demonstration, an individual linear code would typically be used for each part number, description, and quantity, as well as for customer and order number information. If linear codes were used for the bill of lading shown below, the user would have to scan 14 individual bar codes before moving on to the next package. HHP 700 Visions Drive Skaneateles Falls, NY 13153 (315) 685-8945
Order #: 99999
Ship to: ABC Company 123 Highway West San Diego, CA 92100 Customer #: Pick Date: Part Number 3000-12C 6720/B 54/57/UG 42204062
1234567890 March 4, 1998 Description 3000PDF SCANNER 54/57/UG CABLE
Quantity 3 4 3 1
By taking advantage of the enhanced data capacity of PDF417, the user is able to encode all the required information in a single bar code label. Using the Imager and a two-dimensional symbology, the user gets complete information in a single scan. Scan this bar code to display a sample screen for this bill of lading application.
7-9
Page 142
Signature Capture Demonstration Note: This demonstration is appropriate for the 4410LR/LX and 4710LR/LX only. The signature capture demo is performed by scanning the Aztec bar code below the signature box. The Aztec bar code commands the scanner to capture the image of the signature box and its contents and send this image to the host system running Quick*View.
PAUL’S QUICK MART MAIN ST. NEW YORK, NEW YORK 315-123-4567 1122-3344-5678 THU, MAR 04,
1999 09=34B
*** CREDIT CARD *** CARD NO: 00234567899876543 EXP DATE: 0100 CARD TYPE: MC - CREDIT
TR TYPE:
SALE
APP CODE: REC NO:
004910 C009
TOTAL:
$37.99
Sign
7 - 10
Page 143
Snapshot You may also use the IMAGETEAM 4410/4710 to capture an image. Click on Device - Snapshot, or click on the camera icon in the button bar to activate this feature.
Resolution Snapshot icons icon Select the resolution you wish to use for this image, either Full, Half or Quarter Resolution. (These can also be selected by clicking on the 1, 1/2, or 1/4 buttons in the button bar.)
Note: The higher resolution, the sharper the image, and the larger the size of the resulting file. Higher resolution images also take longer to process. You must also select whether you wish to capture the image in Gray Scale or in Black & White.
Black & Gray Scale White
Note: If you need to see exactly what the Imager sees (for example, if you are diagnosing a bar code), you should set the image to Black & White. If you want the Imager to display illuminated aiming brackets, click on Device Snapshot Properties - Use Aimer During Image Capture, or click on the aimer icon in the button bar.
Aimer icon
7 - 11
Page 144
Snapshot, continued Pull the Imager’s trigger to capture an image. Captured images appear in the Quick*View window.
As you move the mouse over the image, the cursor changes to a magnifying glass. Left click to zoom in to the image, right click to zoom out.
Saving an Image File If you wish to save the file as a bitmap, click on File - Save As. Enter the location and file name you wish to use for this file. Click on Save and a bitmap file will be saved.
7 - 12
Page 145
Open Com Port If you wish to open a com port which does not have a device attached, you can do so by selecting File - Open Com Port. This dialog box appears: Click on the arrows to select the Baud Rate, Parity, and Data Bits for the com port you wish to open. Click on Open Port and Quick*View opens the com port whether or not there is a device attached. This feature may be beneficial when troubleshooting a device.
Reporting Firmware Revision To find out what software version the Imager is using, click on Device - Report Device Firmware Revision, or click on the Imager icon in the button bar.
Imager icon This popup lists the firmware information:
7 - 13
Page 146
Load New Imager Software If you need to upgrade the Imager’s software, you can load a new software file into the Imager’s ROM. Click on Device - Load Firmware File into ROM or click on the lightning flash icon in the button bar.
Flash icon
You will be prompted for the name of the hex file:
Select the hex file and click on Open. Quick*View will flash the new software into your Imager’s ROM.
Imager Power Settings By default, the Imager will power down after 2 minutes of inactivity. If you wish to keep the Imager powered up indefinitely, click on Device - Hold Power. To reset the Imager to the default power setting, click on Device - Remove Power Hold.
Trigger Settings If you wish to control the Imager’s trigger with the software, you can select Device - Trigger On, or Device - Trigger Off. These settings turn the trigger on and off just as if you were holding the trigger or releasing it manually. This feature may be necessary when working with a fixed device that has no trigger.
7 - 14
Page 147
RS-232 Serial Commands Click on View - Serial Command Window to display the Command Center window which allows you to enter serial commands to the Imager. Click on View - Scan Data Window to open a window which displays serial data in a text format.
Serial commands are used to program the Imager and to query the Imager about programming parameters. The serial programming commands are listed beginning on page 7-20. Information about performing queries is listed on page page 7-17.
Serial Programming Commands The serial programming commands can be used in place of the programming bar codes listed in Chapter 3. Both the serial commands and the programming bar codes will program the Imager. For complete descriptions and examples of each programming command, refer to Chapter 3. To enter a serial command, click in the Enter Menu Command text box and type in the command(s) you wish to use. If you are typing in more than one command, separate the commands with a semicolon (;). Click on Send Command to send the command(s) to the Imager.
7 - 15
Page 148
Responses The Imager responds to serial commands with one of three responses: ACK Indicates a good command which has been processed. ENQ Indicates a bad command. NAK Indicates the command was good, but the entry was out of the allowable range, e.g., an entry for a minimum message length of 100 when the field will only accept 2 characters.
Command Center Buttons Display All Settings displays the settings currently saved for the Imager. Display Setting Ranges displays all the possible serial commands and the allowable data field parameters. Display Firmware Rev displays the software version being used by the Imager. Build Command Bar Code is used to create an Aztec code from a command or set of commands entered in the Serial Window. (The size of the Aztec code can be altered using the File - Preferences selection.) This bar code can then be printed out and used to program other Imagers. Build Clone Bar Code is used to capture the settings from one Imager, and input them to another Imager. When the Build Clone Bar Code button is clicked, Quick*View captures the settings from the attached Imager and creates an Aztec code which can be printed. (The size of the Aztec code can be altered using the File - Preferences selection.) Any Imager that scans the resulting clone bar code will be programmed to the same settings as the original Imager.
7 - 16
Page 149
Query Commands Several special characters can be used to query the Imager about its settings.
^ ? *
What is the default value for the setting(s). What is the Imager’s current value for the setting(s).
What is the range of possible values for the setting(s). (The Imager’s response uses a dash (-) to indicate a continuous range of values. A pipe (|) separates items in a list of non-continuous values.)
Examples of Query Commands Example #1:What is the range of possible values for Codabar Coding Enable? Enter: cbrena*. Response: CBRENA0-1[ACK] This response indicates that Codabar Coding Enable (CBRENA) has a range of values from 0 to 1 (off and on). Example #2: What is the default value for Codabar Coding Enable? Enter: cbrena^. Response: CBRENA1[ACK] This response indicates that the default setting for Codabar Coding Enable (CBRENA) is 1, or on. Example #3: What is the Imager’s current setting for Codabar Coding Enable? Enter: cbrena?. Response: CBRENA1[ACK] This response indicates that the Imager’s Codabar Coding Enable (CBRENA) is set to 1, or on.
7 - 17
Page 150
Example #4: What are the Imager’s settings for all Codabar selections? Enter: cbr?. Response: CBRENA1[ACK], CHK0[ACK], CKX0[ACK], SSX0[ACK], MIN2[ACK], MAX60[ACK], DFT[ACK]. This response indicates that the Imager’s Codabar Coding Enable (CBRENA) is set to 1, or on; the Check Character (CHK and CKX) is set to 0, or No Check Character; the Start/Stop Character is set to 0, or Don’t Transmit; the Minimum Message Length (MIN) is 2 characters; the Maximum Message Length (MAX) is 60 characters; and the Default setting (DFT) has no value.
Trigger Commands You can activate and deactivate the scanner with the serial trigger commands. First, the scanner must be programmed for accepting serial commands by scanning the Serial Triggering On bar code on page 2-14, or by sending the serial command (TRGSER1.) on page 7-21. When the serial trigger factory default settings are used and serial triggering is enabled, the trigger is activated and deactivated by sending the following commands: Activate Deactivate
SYN T CR SYN U CR
The scanner scans until a bar code has been read, until the deactivate command is sent, or until the serial timeout has been reached. See "Trigger Timeout" on page 2-15 for a description and the serial command on page 7-21.
7 - 18