Page 107

2D Matrix Symbologies Data Matrix < Default All Data Matrix Settings >

Data Matrix

* On

Off

Message Length The message length selection is used to set the valid reading length of the bar code. If the data length of the scanned bar code doesn’t match the valid reading length, the scanner will not read the symbol. You may wish to set the same value for minimum and maximum length to force the scanner to read fixed length bar code data. This helps reduce the chances of a misread. EXAMPLE: Decode only those bar codes with a count of 9-20 characters. Min. length = 09 Max. length = 20 EXAMPLE: Decode only those bar codes with a count of 15 characters. Min. length = 15 Max. length = 15

Minimum Message Length

Maximum Message Length

The desired message length and Save must be input after reading this programming symbol. Refer to the Programming Chart (inside back cover).

3 - 37

Page 108

2D Matrix Symbologies MaxiCode < Default All MaxiCode Settings >

MaxiCode

On

* Off

Message Length The message length selection is used to set the valid reading length of the bar code. If the data length of the scanned bar code doesn’t match the valid reading length, the scanner will not read the symbol. You may wish to set the same value for minimum and maximum length to force the scanner to read fixed length bar code data. This helps reduce the chances of a misread. EXAMPLE: Decode only those bar codes with a count of 9-20 characters. Min. length = 09 Max. length = 20 EXAMPLE: Decode only those bar codes with a count of 15 characters. Min. length = 15 Max. length = 15

Minimum Message Length

Maximum Message Length

The desired message length and Save must be input after reading this programming symbol. Refer to the Programming Chart (inside back cover).

3 - 38

Page 109

2D Matrix Symbologies MaxiCode, continued Structured Carrier Message Only A MaxiCode is made up of a primary and secondary message. The primary portion, also known as the “structured carrier message,” contains information of primary importance, such as package destination. The secondary portion contains less important data, such as package weight. If your application requires only the primary data from MaxiCodes, turn Structured Carrier Message Only On. Turn this feature on if you are trying to read a damaged Maxicode. The scanner may be able to extract just the structured carrier message if the center portion of the code is intact.

On

* Off

3 - 39

Page 110

2D Matrix Symbologies Aztec Code < Default All Aztec Code Settings >

Aztec Code

* On

Off

Message Length The message length selection is used to set the valid reading length of the bar code. If the data length of the scanned bar code doesn’t match the valid reading length, the scanner will not read the symbol. You may wish to set the same value for minimum and maximum length to force the scanner to read fixed length bar code data. This helps reduce the chances of a misread. EXAMPLE: Decode only those bar codes with a count of 9-20 characters. Min. length = 09 Max. length = 20 EXAMPLE: Decode only those bar codes with a count of 15 characters. Min. length = 15 Max. length = 15

Minimum Message Length

Maximum Message Length

A one- to two-digit number and Save are required after reading this programming symbol. Refer to the Programming Chart (inside back cover).

3 - 40

Page 111

Diagnostics Test Menu When you scan the Test Menu On code then scan a programming code in this manual, the scanner displays the content of a programming code. The programming function will still occur, but in addition, the content of that programming code is output to the terminal. You may wish to use this feature in conjunction with Quick*View (see page 7-1).

Note: This feature should not be used during normal scanner operation.

On

* Off

2D PQA (Print Quality Assessment) Two-dimensional Print Quality Assessment (2D PQA) is a feature of HHP’s image readers where the data from the successful read of a 2D bar code symbol is augmented with lines of text both identifying the symbol and also reporting graded measurement parameters obtained from it. To utilize 2D PQA, you need to have an IT4410/4710 with revision 1.91.2.18 or higher. To see displayed results, Microsoft® Notepad, a word processor/editing program, or Quick*View (see page 7-1) is recommended. For additional information on interpreting your read results, please refer to the Quick Check 2D Print Assessment User’s Guide.

3 - 41

Page 112