The text of a manual · part 2 of 19
4800p 2D Imager User's Guide, pages 11 to 20
Pages 11 to 20 of 184
The original document is the PDF (918 KB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the HHP 4800p and Honeywell 4800p
Page 11
Data Matrix Message Length .............................. 6-45 MaxiCode Message Length................................. 6-46 Aztec Code Message Length .............................. 6-47 Aztec Runes ........................................................ 6-47
Chapter 7 - Imaging Commands Image Snap - IMGSNP ............................................... 7-1 IMGSNP Modifiers................................................. 7-1 Image Ship - IMGSHP................................................. 7-2 IMGSHP Modifiers................................................. 7-3 Image Size Compatibility....................................... 7-6 Intelligent Signature Capture - IMGBOX ..................... 7-7 IMGBOX Modifiers ................................................ 7-7
Chapter 8 - OCR Programming OCR ............................................................................ 8-1 OCR Templates .......................................................... 8-3 Creating an OCR Template................................... 8-3 Stringing Together Multiple Formats (Creating “Or” Statements) .............................. 8-6 OCR User-Defined Variables ...................................... 8-6 Reading Multi-Row OCR ....................................... 8-7 OCR Check Character ................................................ 8-8 OCR Modulo 10 Check Character......................... 8-8 OCR Modulo 36 Check Character......................... 8-8 OCR User-Defined Check Character .......................... 8-9 Weighting Options ............................................... 8-10 OCR ISBN Application Example ............................... 8-11 OCR Template Codes ............................................... 8-13
Chapter 9 - Interface Keys Keyboard Function Relationships ............................... 9-1 Supported Interface Keys............................................ 9-3 v
Page 12
Chapter 10 - Utilities To Add a Test Code I.D. Prefix to All Symbologies ... 10-1 Show Decoder Revision ............................................ 10-1 Show Engine Revision............................................... 10-1 Show Scan Driver Revision ....................................... 10-2 Show Software Revision............................................ 10-2 Show Data Format..................................................... 10-2 Resetting the Standard Product Defaults .................. 10-2 Test Menu.................................................................. 10-3 2D PQA (Print Quality Assessment) .......................... 10-3 2D PQA Reporting ............................................... 10-3 Visual Xpress™ Introduction ...................................... 10-4 Installing Visual Xpress from the Web ................. 10-5
Chapter 11 - Serial Programming Commands Conventions............................................................... 11-1 Menu Command Syntax ............................................ 11-1 Query Commands................................................ 11-2 Concatenation of Multiple Commands ................. 11-2 Responses ........................................................... 11-2 Examples of Query Commands ........................... 11-3 Resetting the Standard Product Defaults .................. 11-4 Menu Commands ...................................................... 11-4
Chapter 12 - Product Specifications 4800p Specifications.................................................. 12-1 Connector Pinouts ............................................... 12-2
Chapter 13 - Maintenance Repairs ...................................................................... 13-1 Maintenance .............................................................. 13-1 Cleaning the Device............................................. 13-1 Inspecting Cords and Connectors ....................... 13-1 Replacing the Interface Cable ............................. 13-2 vi
Page 13
Troubleshooting ........................................................ 13-2
Chapter 14 - Customer Support Technical Assistance ................................................ 14-1 Online Technical Assistance ............................... 14-1 Product Service and Repair ...................................... 14-2 Online Product Service and Repair Assistance... 14-3 Limited Warranty ....................................................... 14-3
Appendix A - Appendix A ASCII Conversion Chart (Code Page 1252) ............... A-4 Code Page Mapping of Printed Bar Codes ................. A-6 vii
Page 14
viii
Page 15
1
Getting Started About This Manual This User’s Guide provides installation and programming instructions for the 4000 Series imagers. Product specifications, dimensions, warranty, and customer support information are also included. Honeywell bar code imagers are factory programmed for the most common terminal and communications settings. If you need to change these settings, programming is accomplished by scanning the bar codes in this guide. An asterisk (*) next to an option indicates the default setting.
Unpacking the Imager After you open the shipping carton, take the following steps: • Check for damage during shipment. Report damage immediately to the carrier who delivered the carton. • Make sure the items in the carton match your order. • Save the shipping container for later storage or shipping.
1-1
Page 16
Imager Models The chart below lists the interfaces that can be used with your imager. Models
Primary
4800pSF151CE
USB keyboard, USB COM port emulation
4800oSF151C0F00E
USB kit
Imager Identification
Item Number, Serial Number and Revision Information location Compliance Label location
1-2
Page 17
Connecting the Imager with USB Note: See "Imager Models" on page 1-2 to determine which interfaces apply to your imager. An imager can be connected to the USB port of a computer. 1. Connect the appropriate interface cable to the imager first, then to the computer.
2. Program the imager for a USB interface using the Plug and Play bar codes beginning on page 1-4. 3. The imager beeps. 4. Verify the imager operation by scanning a bar code from the Sample Symbols in the back of this manual. For additional USB programming and technical information, refer to Honeywell “USB Interface Application Note,” available at www.honeywellaidc.com.
1-3
Page 18
Programming the Interface - Plug and Play Plug and Play bar codes provide instant imager set up for commonly used interfaces.
Note: After you scan one of the codes, power cycle the host terminal to have the interface in effect. Note: See "Imager Models" on page 1-2 to determine which interfaces apply to your imager.
USB PC or Macintosh® Keyboard Scan one of the following codes to program the imager for USB PC Keyboard or USB Macintosh Keyboard. Scanning these codes adds a CR and selects the terminal ID (USB PC Keyboard - 124, USB Macintosh Keyboard - 125, USB Japanese Keyboard - 134).
USB Keyboard (PC)
USB Keyboard (Mac)
USB Japanese Keyboard (PC)
USB HID Scan the following code to program the imager for USB HID bar code imagers. Scanning this code changes the terminal ID to 131.
USB HID Bar Code Imager
1-4
Page 19
USB COM Port Emulation Scan the following code to program the imager to emulate a regular RS-232based COM port. If you are using a Microsoft® Windows® PC, you will need to download a driver from the Honeywell website (www.honeywellaidc.com). The driver will use the next available COM port number. Apple® Macintosh computers recognize the imager as a USB CDC class device and automatically use a class driver. Scanning the code below changes the terminal ID to 130.
USB COM Port Emulation
Note: No extra configuration (e.g., baud rate) is necessary.
CTS/RTS Emulation
On
* Off
ACK/NAK Mode
On
* Off
Reading Techniques The 4800p scans bar codes and also captures images. It can be used with or without a stand.
1-5
Page 20
The 4800p’s viewfinder projects a green aiming beam that should be centered over the bar code, but can be positioned in any direction for a good read. Linear bar code
2D Matrix symbol
Hold the scanner with the aiming beam centered over the bar code. The 4800p beeps when it successfully reads a bar code. Do not move the 4800p over another bar code until it beeps. The optimum distance between the 4800p and the object being scanned is 2 to 5 inches (5.1 - 12.7 cm). The height from the 4800p to the stand’s tray is the proper distance. The aiming beam is smaller when the imager is closer to the code and larger when it is farther from the code. Symbologies with smaller bars or elements (mil size) should be read closer to the unit. Symbologies with larger bars or elements (mil size) should be read farther from the unit. If the code being scanned is highly reflective (e.g., laminated), it may be necessary to tilt the code +5° to prevent unwanted reflection.
4800p Stand The stand holds the 4800p at a fixed distance for capturing images or reading bar codes on security/identification cards. The wedge insert supplied with the stand provides the optimum angle for scanning and capturing images in most lighting conditions. The card should be placed on the wedge with the bar code closest to the back of the stand.
1-6