For the Fujitsu 3500

Page 41

Appendix A Agency Notices UL Notices

3 Cautions

• Changes or modifications not expressly approved by Fujitsu PC Corporation could void this user’s authority to operate the equipment. • This unit requires an AC Adapter to operate. Use only UL Listed “Class 2” adapters with an output rating of 16 Vdc, 3.36 A. AC Adapter output polarity:

+ • To reduce the risk of fire, use only No. 26 or larger telecommunication line cord. • To charge the battery pack FMW45BP1 externally, use only a Stylistic external battery charger model FMW42BC1. • There is a danger of explosion if the Lithium (CMOS) battery is incorrectly replaced. Replace only with the same or equivalent type recommended by the manufacturer. Dispose of used batteries according to manufacturer's instruction.

Warning (For Authorized Repair Technicians only:) • For continued protection against the risk of fire, replace fuse only with the same type and rating of fuse..

FCC Notices

3

This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC rules. Changes or modifications not expressly approved by Fujitsu PC Corporation, could void the user’s authority to operate the equipment.

Agency Notices

35

Page 42

Notice to Users of Radios and Television

3

These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If the equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: • Reorient or relocate the receiving antenna. • Increase the separation between the equipment and receiver. • Connect the equipment into an outlet that is on a different circuit than the receiver. • Consult the dealer or an experienced radio/TV technician for help. Shielded interconnect cables must be employed with this equipment to ensure compliance with the pertinent RF emissions limits governing this device.

Notice to Users of the US Telephone Network

3

The Stylistic 3500 pen tablet is supplied with an internal modem which complies with Part 68 of the FCC rules. On the pen tablet is a label that contains the FCC Registration Number and Ringer Equivalence Number (REN) of this system, along with other information. If requested, users must provide their telephone company with the following information: • The telephone number to which the pen tablet is connected • The Ringer Equivalence Number (REN) for this equipment • The information that the system requires a standard modular jack type USOC RJ-11C which is FCC Part 68-compliant • The FCC Registration Number This equipment is designed to be connected to the telephone network or premises wiring using a standard modular jack type USOC RJ-11C which is FCC Part 68-compliant. The REN is used to determine the number of devices you may connect to your telephone line and still have all those devices ring when your number is called.Too many devices on one line may result in failure to ring in response to an incoming call. 36

Appendix

Page 43

In most, but not all, areas, the sum of all of the devices should not exceed five (5). To be certain of the number of devices you may connect to your line, as determined by the RENs, contact your local telephone company. If this equipment causes harm to the telephone network, your telephone company may discontinue your service temporarily. If possible, they will notify you in advance. If advance notice is not practical, they will notify you as soon as possible. You will also be advised of your right to file a complaint with the FCC. This fax modem also complies with fax branding requirements per FCC Part 68. If you experience trouble with this equipment, please contact your support representative. Your telephone company will probably ask you to disconnect this equipment from the telephone network until the problem is corrected and you are sure that the equipment is not malfunctioning. This equipment may not be used on coin service telephones provided by your telephone company. Connection to party lines is subject to state tariffs. Contact your state’s public utility commission, public services commission, or corporation commission for more information. FCC rules prohibit the use of non-hearing aid compatible telephones in the following locations or applications: • All public or semipublic coin-operated or credit card telephones. • Elevators, highways, tunnels, (automobile, subway, railroad, or pedestrian) where a person with impaired hearing might be isolated in an emergency. • Places where telephones are specifically installed to alert emergency authorities such as fire, police, or medical assistance personnel. • Hospital rooms, residential health care facilities, convalescent homes, and prisons. • Workstations for the hearing impaired. • Hotel, motel, or apartment lobbies. • Stores where telephones are used by patrons to order merchandise. • Public transportation terminals where telephones are used to call taxis or to reserve lodging or rental cars. • In hotel and motel rooms at least ten percent of the rooms must contain hearing aid compatible telephones which will be provided to hearing impaired customers on request. Agency Notices

37

Page 44

DOC (Industry Canada) Compliance Notices

3

This digital apparatus does not exceed the Class B limits for radio noise emissions from digital apparatus as set forth in the radio interference regulations of the Canadian Department of Communications. Le présent appareil numérique n’émet pas de bruits radioélectriques dépassant les limites applicables aux appareils numériques de classe B prescrites dans le règlement sur le brouillage radioélectrique édicté par le Ministère des Communications du Canada.

Notice to Users of Radios and Television

3

This Class B digital apparatus meets all requirements of the Canadian Interference-Causing Equipment regulations. Cet appareil numérique de la classe B respecte toutes les exigences du règlement sur le matériel brouilleur du Canada.

Notice to Users of the Canadian Telephone Network

3

The Canadian Industry Canada label identifies certified equipment. This certification means that the equipment meets certain telecommunications network protective, operational, and safety requirements. The Department does not guarantee the equipment will operate to the user’s satisfaction. Repairs to telecommunication equipment should be made by a Canadian authorized maintenance facility. Any repairs or alterations not expressly approved by Fujitsu PC Corporation or any equipment failures may give the telecommunications company cause to request the user to disconnect the equipment from the telephone line. The connecting arrangement code for this equipment is CA11A. The Load Number assigned to each telephone terminal device denotes the percentage of the total load to be connected to a telephone loop or circuit to be used by the device to prevent overloading. The termination on a loop may consist of any combination of devices such that the total of the load numbers of all devices does not exceed 100.

38

Appendix

Page 45

Caution For safety, users should ensure that the electrical ground of the power utility, the telephone lines, and the metallic water pipes are connected together. Users should not attempt to make such connections themselves but should contact the appropriate electric inspection authority or electrician. This may be particularly important in rural areas.

Avis Aux Utilisateurs Du Réseau Téléphonique Canadien

3

L’étiquette canadienne Industrie Canada identifie l’équipement certifié. Cette certification signifie que l’équipement satisfait certaines normes de protection, d’exploitation et de sécurité des réseaux de télécommunications. Le département ne garantit pas le fonctionnement de l’équipement à la satisfaction de l’utilisateur. Le Stylistic 3500 possede un modem interne conforme aux normes de certification d’Industrie Canada pour protéger les réseaux de télécommunications et satisfaire aux normes de sécurité. Avant de connecter cet équipement à une ligne téléphonique, l’utilisateur doit vérifier s’il est permis de connecter cet équipement aux installations de télécommunications locales. L’utilisateur est averti que même la conformité aux normes de certification ne peut dans certains cas empêcher la dégradation du service. Les réparations de l’équipement de télécommunications doivent être effectuées par un service de maintenance agréé au Canada. Toute réparation ou modification, qui n’est pas expressement approuvée par Fujitsu PC Corporation, ou toute défaillance de l’équipement peut entrainer la compagnie de télécommunications à exiger que l’utlilisateur déconnecte l‘équipement de la ligne téléphonique. Le code d’arrangement de connexion de cet équipement est CA11A. Le numéro de charge assigné à chaque terminal téléphonique indique le pourcentage de la charge totale pouvant être connecté à une boucle ou à un circuit téléphonique, utilisé par ce périphérique afin de prévenir toute surcharge. La terminaison d’une boucle peut être constituée de n’importe quelle combinaison de périphériques de sorte que le total de numéros de charge de tous les périphériques n’excède pas 100.

Agency Notices

39

Page 46

Avertissement Pour assurer la sécurité, les utilisateurs doivent vérifier que la prise de terre du service d’électricité, les lignes téléphoniques et les conduites d’eau métalliques sont connectées ensemble. Les utilisateurs NE doivent PAS tenter d’établir ces connexions eux-mêmes, mais doivent contacter les services d’inspection d’installations électriques appropriés ou un électricien. Ceci peut être particulièrement important en régions rurales.

40

Appendix

Page 47

Appendix B Stylistic 3500 Hardware Specifications The following table provides general hardware specifications of the Stylistic 3500 by category. Stylistic 3500 Specifications Physical Specifications Dimensions

11” w x 8.5” d x 1.1” h (280mm x 215mm x 27.4mm)

Weight

3.2 lbs. (1.45 Kg) Processing Specifications

CPU

Intel Celeron 500MHz, 1.1V

Chip set

Intel 440MX - 100

Processor Speed

500 MHz Memory/Storage Specifications

3

3

3

Main RAM

64MB, 128MB, and 256MB module configurations available, with a system maximum of 256MB.

L1 cache (CPU)

32 KB on die

L2 cache

128 KB on die

BIOS ROM

512 KB (flash ROM upgradeable)

Hard disk drive

• 2.5” HDD • 15GB IDE HDD • Ultra DMA • Shock-mounted

Stylistic 3500 Hardware Specifications

41

Page 48

Stylistic 3500 Specifications (Continued) Input/Output Specifications Display

3

• Indoor Color LCD Transmissive 10.4” TFT XGA (1024 x 768) 256K colors Brightness: 8 levels • Indoor/Outdoor Color LCD Transmissive 10.4” TFT SVGA (800 x 600) 256K colors Brightness: 8 levels • Outdoor Color LCD Reflective 10.4” TFT SVGA (800 x 600) 256K colors

VRAM

4MB RAM Interface Specifications

PC Card Slots

• One Type-II • PCMCIA CardBus version 3.0

Integrated Interfaces

• FDD • RJ-11 • USB • DC-In • Serial connector • Expansion connectors

Infrared

IrDA version 1.1 (FIR, 4Mbps)

Audio

• Sound Function + AC’97 codec (18-bit stereo codec) • Internal microphone and speaker • Microphone and headphone jacks

High-Usage Docking Contacts

42

Appendix

• DC-In • USB Host

3

Page 49

Stylistic 3500 Specifications (Continued) User Controls

• Hotpads: programmable, volume, display, brightness, right button, hovering • Power On/Suspend/Resume button • Emergency Shutoff Button (Power Off button)

Status Indicators (LEDs)

• Power • Charge/DC-In • Battery level • HDD • Hovering Power Specifications

Main Battery

3

• 6-cell • Removable, Lithium ion • 10.8 V @ 3100 mAh • Warm-swappable • Recharge Time: Suspend/Off: 3 hours (90%), 4 hours (100%) Operating: 8 hours (100%) • Life: ~4 hours (Battery life is dependent upon the operating system, power management, and applications in use.) • Suspend Life: Minimum 5 days Off State: Approximately 30 days

Sub-Battery

• 6-cell NiMH, 35 mAh • Life (with system running on sub-battery only): ~5 minutes from full charge Environmental Specifications

Temperature

Operating: 0o - 40o C (32o - 104o F) Non-operational: -20o - 60o C (-4o - 140o F)

Humidity

Operating: 20 - 80% non-condensing Non-operating: 20-80% non-condensing

Stylistic 3500 Hardware Specifications

3

43

Page 50

Stylistic 3500 Specifications (Continued) Agency Approval Specifications

3

• EN55022 (CISPR22) Class B Emissions

• FCC 15, Class B • DOC Class B • EN61000-4-2:1995

Immunity

• EN61000-4-3:1995 • EN61000-4-4:1995 • UL and cUL Listed, UL 1950

Safety

• TuV T-Mark, EN60950 • FCC Part 68

Telecom

• IC CS03 Additional Specifications

Operating systems

44

Appendix

Microsoft Windows Windows 2000

98, Windows NT 4.0 Workstation,

3