Festo operating instructions in six languages (part 375 092, version 9709 A) for filters, micro-filters, pressure regulators and filter regulators of types LF-M, LFM-M, LR-M, LRB-M and LFR-M. The sheet covers the LR regulator family in general and does not name the LR-M2-N3/8-10G itself. It explains fitting, joining units, setting the pressure, maintenance and faults, and gives the technical data.

Device
Festo filters, micro-filters, pressure regulators and filter regulators, types LF, LFM, LR, LRB and LFR p. 1
Function
LR, LRB and LFR types: bring incoming compressed air to the set working pressure and even out pressure swings p. 1
Medium
Compressed air only p. 1
Max. inlet pressure
LR-/LRB- types: 21 bar (305 psi), at -10 °C (+14 °F) to +80 °C (+176 °F) p. 1
Inlet vs outlet
Inlet pressure at least 1 bar above the outlet pressure p. 1
Working pressure
Maximum working pressure range p2: see the label on the unit p. 1
Gauge port
LR-/LFR-M2/3-N types: N1/4; M2/3-G types: G1/4; M1 types: N1/8 or G1/8 p. 1
Fitting position
LR-/LRB- types: any position; filter types upright within ±5° p. 1
Materials
Zinc housing, nitrile seals p. 1
Service interval
Regulator serviced every six months; filter element replaced at least every 12 months p. 1
Cleaning agent
Water or soap solution, max. +60°C p. 1
Document number
Festo part 375 092, version 9709 A p. 1

What this manual walks you through

  • Fitting the unit: shut-off valves, flow direction and space below the bowl p. 1
  • Joining M2 and M3 units to another maintenance unit with a joiner p. 1
  • Fitting the pressure gauge p. 1
  • Setting the regulator to the working pressure p. 1
  • Draining condensate and replacing the filter element p. 1
  • Servicing the regulator: diaphragm, seals and valve assembly p. 1
  • Fault table with causes and remedies p. 1

Good to know

  • For compressed air only; any other liquid or gas is a misapplication. p. 1
  • Fitting and commissioning are for qualified personnel only. p. 1
  • Pressurize the complete system slowly to avoid sudden uncontrolled movements. p. 1
  • Unauthorized modification of the product is not permitted. p. 1
  • Leave at least 100 mm below the filter bowl to change the filter element. p. 1

Questions this manual answers

How do I set the pressure on a Festo LR regulator?

Pressurize slowly, pull the setting knob up, turn it until the gauge shows the pressure you want, then press it down to lock it. p. 1

What is the maximum inlet pressure of a Festo LR regulator?

21 bar (305 psi) for LR- and LRB- types, over -10 °C to +80 °C (+14 °F to +176 °F). p. 1

What gauge thread does a Festo LR-M2 N-type regulator use?

N1/4 for LR- and LFR-M2/3-N types. p. 1

How often should a Festo regulator be serviced?

Every six months: take it apart, inspect the diaphragm and seals, clean and lubricate the valve assembly, and replace worn parts. p. 1

The file

Size and text

Pages2
PDF89 KB
TextText from the PDF itself.

Every page · 2

Read it here

Each page as it is printed, and its words beside it, so a phone can search and copy them.

Page 1 of Festo LF, LR and LFR Filter and Pressure Regulator Operating Instructions

The text of page 1, from the PDF itself

Postfach 6040 D-73726 Esslingen Telefon (07 11) 3 47-0

Quelltext: englisch Version: 9709 A Teile Nr.: 375 092

D Bedienungsanleitung

GB Operating instructions

S

Bruksanvisning

Filter, Fein-/Feinstfilter Druck-Regelventil, Filter-Regelventil Typ LF-M.-..., LFM-M.-..., LR-M.-..., LRB-M.-..., LFR-M.-...

Filter, micro-filter pressure regulator, filter regulator Type LF-M.-..., LFM-M.-..., LR-M.-..., LRB-M.-..., LFR-M.-...

Filter, mikrofilter tryckregulator, filterregulator Typ LF-M.-..., LFM-M.-..., LR-M.-..., LRB-M.-..., LFR-M.-...

Einbau und Inbetriebnahme nur von autorisiertem Fachpersonal, gemäß Bedienungsanleitung. Diese Produkte sind ausschließlich zur Verwendung mit Druckluft vorgesehen. Zur Verwendung mit anderen Medien (Flüssigkeiten oder Gasen) sind sie nicht geeignet.

Fitting and commissioning to be carried out by qualified personnel only in accordance with the operating instructions. These products are specifically designed for compressed air use only. Use with any other fluid (liquid or gas) is a misapplication.

Montering och idrifttagning får endast utföras av auktoriserad fackkunnig personal i enlighet med denna bruksanvisning. Dessa produkter är endast avsedda för användning med tryckluft. De lämpar sig ej för användning med andra medier (vätskor eller gaser).

{ Anwendung{ Application{ Användning

Das LFR-..., LR-..., LRB-... regelt die zugeleitete Druckluft auf den eingestellten Arbeitsdruck und gleicht Druckschwankungen aus. Das LF-..., LFM-..., LFR-... mit Wasserabscheider befreit die Druckluft von Schmutzpartikeln und Kondenswasser.

The LFR-..., LR-..., LRB-... adjusts the incoming compressed air to the set working pressure and compensates fluctuations in pressure. The LF-..., LFM-..., LFR-... with water separator frees the compressed air of dirt particles and condensed water.

LFR-..., LR-..., LRB-... reglerar den inmatade tryckluften till det inställda arbetstrycket och utjämnar tryckvariationer. LF-..., LFM-..., LFR-... med vattenavskiljare filtrerar tryckluften från smutspartiklar och kondens.

; Voraussetzungen für den Produkteinsatz

; Safety conditions

; Förutsättningar för korrekt användning

Allgemeine, stets zu beachtende Hinweise für den ordnungsgemäßen und sicheren Einsatz des Produkts:

  • Halten Sie die angegebenen Grenzwerte ein (z.B. für Drücke, Kräfte, Momente, Massen, Geschwindigkeiten, Temperaturen, elektrische Spannungen).
  • Berücksichtigen Sie die vorherrschenden Umgebungsbedingungen.
  • Beachten Sie die Vorschriften der Berufsgenossenschaft, des Technischen Überwachungsvereins oder entsprechende nationale Bestimmungen.
  • Belüften Sie Ihre gesamte Anlage langsam. Dann treten keine unkontrollierten Bewegungen auf.
  • Verwenden Sie das Produkt im Originalzustand ohne jegliche eigenmächtige Veränderung.

These general conditions for the correct and safe use of the product must be observed at all times:

  • Please observe the limits for pressure, forces, torques, masses, speeds, temperatures and electric voltages.
  • Please observe the prevailing ambient conditions.
  • Please comply with national and local safety laws and regulations.
  • Slowly pressurize the complete system. This will prevent sudden uncontrolled movements from occurring.
  • Unauthorized product modification is not permitted.

= Einbau= Fitting= Montering

  • Verwenden Sie Absperrventile, um die Anlage für Montage und Wartung
  • Use shut-off valves for depressurizing the system for fitting and maintenance
  • Använd avstängningsventiler för att göra anläggningen trycklös vid montering och

(z.B. Filterwechsel) drucklos zu schalten.

(e.g. when changing the filter).

  • Beachten Sie die Durchflußrichtung. Diese ist an den Hinweispfeilen auf dem

Produkt abzulesen.

  • Berücksichtigen Sie genügend Platz unterhalb der Filterschale (min. 100 mm) für

den Filterwechsel.

av produkten Följande allmänna anvisningar för korrekt och säker användning av produkten skall alltid följas:

  • De angivna gränsvärdena (t ex tryck, krafter, moment, massor, hastigheter, elektriska spänningar och temperaturer) får inte överskridas.
  • Ta hänsyn till omgivande förhållanden.
  • Följ gällande lagar och säkerhetsbestämmelser.
  • Pålufta hela anläggningen långsamt. Då uppträder inga okontrollerade rörelser.
  • Använd produkten i originalskick utan egna modifieringar

underhåll (t ex filterbyte).

  • Please note the direction of flow. This is shown by the arrows on the product.
  • Allow sufficient space below the filter bowl (at least 100mm) to replace a dirty filter

element.

  • Beakta flödesriktningen. Denna framgår av pilarna på produkten.
  • Se till att det finns tillräckligt utrymme under filterkoppen (min 100 mm) för filterbyte.
  • Justera LF-..., LFM..-..., LFR-... i lodrätt läge (±5º)
  • Adjust the LF-..., LFM..-..., LFR-... when it is standing upright (±5º).

Vid gemensam montering av filter och mikrofilter till en filterkombination:

In combining the fine and ultra-fine filters to form an LFM-... filter:

  • Please observe the sequence of the micro filters in the direction of flow. The LFM-..-../.-B filter (1 µm) must be in front of the LFM-..-../.-A filter (0,01 µm).
  • Beakta ordningsföljd och flödesriktning hos mikrofiltren.

Fitted together with another maintenance unit of the same type:

  • M1 units: 1. Install O-ring into outlet port (P2) of first unit in the combination series. 2. Place first and second units of the combination series together (outlet port (P2) to inlet port (P1)) and place back flange tabs in the T-bracket groove. 3. Place clamp groove over front flange tabs and install screws tightly. 4. Repeat as required.
  • M2 and M3 units: 1. Install O-rings (2 each) into both sides of joiner. 2. Slide joiner, starting from the back and sliding towards the front, into outlet port (P2) joiner guides of 1st unit in the combination series. 3. Slide inlet port (P1) of second unit into joiner. 4. Align joiner retainer with screw over hole in front of joiner and screw in tightly. 5. Repeat as required for each unit in the combination series. 6. Place T-bracket on back of joiner and install screws tightly repeating as required. Fitting the Gauge: 1. Locate the gauge in the existing threaded connector. 2. The alternative connection is closed with a blind plug. 3. If necessary, replace the blind plug (include. seal). 4. Tighten the gauge and, if necessary, the blind plug.
● M1-aggregat
% Inbetriebnahme

% Commissioning

% Idrifttagning

Zur Einstellung des Reglers LR-..., LRB-..., LFR-...: 1. Belüften Sie Ihre gesamte Anlage langsam. 2. Ziehen Sie den Druck-Einstellknopf zur Entriegelung nach oben (vom Gehäuse weg). 3. Drehen Sie den Druck-Einstellknopf, bis der gewünschte Druck am Manometer angezeigt wird. Der Eingangsdruck muß mindestens 1 bar größer sein als der Ausgangsdruck. 4. Drücken Sie den Druck-Einstellknopf nach unten (zum Gehäuse hin). Dadurch sichern Sie ihn gegen ungewolltes Verdrehen.

Adjusting the regulator LR-..., LRB-..., LFR-...: 1. Slowly pressurize the complete system. 2. Pull the pressure setting button upwards (away from the housing). 3. Turn the pressure setting until the desired pressure is shown on the manometer. The input pressure must be at least 1 bar greater than the output pressure. 4. Press the pressure setting button downwards (towards the housing) to secure it against unintentional turning.

För inställning av regulatorn LR-..., LRB-..., LFR-....: 1. Pålufta hela anläggningen långsamt. 2. Dra tryckinställningsratten uppåt för att lossa spärren (ifrån huset). 3. Vrid tryckinställningsratten tills önskat tryck visas på manometern. Ingångstrycket skall vara minst 1 bar högre än utgångstrycket. 4. Tryck tryckinställningsratten nedåt (mot huset). Detta spärrar den mot ofrivillig vridning.

& Wartung und Pflege

& Maintenance and Care

& Underhåll och skötsel

Bei Erreichen des Kondensat-Pegels ”MAX” an der Schale:

  • Drehen Sie die Ablaßschraube gegen den Uhrzeigersinn (von unten gesehen) auf. Dadurch wird das Kondensat abgelassen. Bei geringerem Durchfluß trotz unveränderter Druckeinstellung:
  • Wechseln Sie die Filterpatrone mindestens alle 12 Monate. 1. Anlage und Gerät entlüften. 2. Filterschale gegen den Uhrzeigersinn (von unten gesehen) losdrehen. 3. Filterhalterung gegen den Uhrzeigersinn (von unten gesehen) losdrehen. 4. Filterpatrone wechseln. 5. Einzelteile in umgekehrter Reihenfolge montieren. 6. Wiederinbetriebnahme gemäß Kapitel ”Inbetriebnahme”. Regler alle sechs Monate warten.
  • Regler zerlegen.
  • Membran und Dichtungen kontrollieren.
  • Ventileinheit und O-Ring kontrollieren, reinigen und schmieren.
  • Verschlissene oder beschädigte Teile ersetzen.

If condensate level reaches the ”MAX” level on the bowl guard:

  • Open the bleeder screw by turning it in an anti-clockwise direction when viewed from the bottom. The condensate can then flow out. With less flow despite same pressure setting:
  • Replace the filter element, at least every 12 months. 1. Exhaust the system and the unit. 2. Unscrew the filter bowl in an anti-clockwise direction when viewed from the bottom. 3. Unscrew the filter retainer in an anti-clockwise direction when viewed from the bottom. 4. Replace the filter element. 5. Refit the parts in the reverse order from dismantling. 6. Recommission as described in the section ”Commissioning”. Service regulator every six months.
  • Disassemble regulator.
  • Inspect diaphragm and seals.
  • Inspect, clean, and lubricate valve assembly and o-ring.
  • Replace worn or damaged parts.

När kondensatnivån ”MAX” uppnås i koppen:

  • Öppna avtappningsskruven moturs (sett underifrån). Därigenom släpps kondensvattnet ut. Vid minskat genomflöde trots oförändrad tryckinställning:
  • Byt filterinsatsen med max 12 månaders intervall. 1. Avlufta anläggning och aggregat. 2. Skruva loss filterkoppen moturs (sett underifrån). 3. Skruva loss filterhållaren moturs (sett underifrån). 4. Byt filterinsats. 5. Montera de enskilda delarna i omvänd ordningsföljd. 6. Ny idrifttagning i enlighet med kapitlet ”Idrifttagning”. Service skall utföras på regulatorn med sex månaders intervall.
  • Ta isär regulatorn.
  • Kontrollera membran och tätningar.
  • Kontrollera ventilenhet och O-ring, rengör och smörj.
  • Byt slitna eller skadade delar.

Reinigung

  • Nur die angegebenen Reinigungsmittel verwenden:

Cleaning

  • Use only the cleaning agents specified:
  • Använd endast angivna rengöringsmedel:

Bauteil FilterschaleComponent Filter bowlDetalj Filterkopp

  • Justieren Sie den LF-..., LFM..-..., LFR-... in senkrechter Stellung (±5º).

Beim Zusammenbau von Fein- und Feinstfilter zu einer Filterkombination:

  • Beachten Sie die Reihenfolge und Durchflußrichtung der Feinstfilter.

Der Filter LFM-..-../.-B (1 µm) muß dem Filter LFM-..-../.-A (0,01 µm) vorgeschaltet sein. Beim Zusammenbau mit einem bereits vorhandenen Wartungsgerät der gleichen Baureihe:

  • M1-Geräte:

1. O-Ring im Ausgangsanschluß (P2) des ersten Gerätes in der Kombination anbringen. 2. Erstes und zweites Gerät der Kombination zusammenbauen (Ausgangsanschluß (P2) an Eingangsanschluß (P1)) und die Nasen des hinteren Flansches in die Nut des Verbindungsstücks schieben. 3. Nut des Klemmstücks über die Nasen des vorderen Flansches schieben und Schrauben fest anziehen. 4. Nach Bedarf wiederholen.

  • M2- und M3-Geräte: 1. O-Ringe auf beiden Seiten des Verbindungsstücks anbringen. 2. Das Verbindungsstück von hinten beginnend nach vorn in die Führungen des Ausgangsanschluß (P2) des ersten Geräts in der Kombination hineinschieben. 3. Den Eingangsanschluß (P1) des zweiten Geräts in das Verbindungsstück hineinschieben. 4. Das Klemmstück mit Schraube auf die Bohrung am Verbindungsstück ausrichten, Schraube eindrehen und fest anziehen. 5. Nach Bedarf für jedes weitere Gerät in der Kombination wiederholen. 6. Einen Befestigungswinkel auf der Rückseite des Verbindungsstücks anbringen und beide Schrauben fest anziehen. Zum Einbau des Manometers: 1. Plazieren Sie das Manometer in das vorhandene Anschlußgewinde. 2. Der Alternativanschluß ist mit einer Verschlußschraube verschlossen. 3. Setzen Sie gegebenenfalls die Verschlußschraube (einschließlich Dichtung) um. 4. Drehen Sie das Manometer und gegebenenfalls die Verschlußschraube fest.

Reinigungsmittel Wasser oder Seifenlauge (max. +60°C)

( Störungsbeseitigung Störung Keine Druckanzeige

Abhilfemaßnahme Absperrventil öffnen Mit Druck-Einstellknopf Druck einstellen

Cleaning Agent Water or soap sup (max. +60°C)

Manometer defekt

Manometer austauschen

Geringer Durchfluß Filterpatrone verschmutzt (bei Luftverbrauch bricht der Verengung zwischen Betriebsdruck zusammen) Absperrventil und

Filterpatrone wechseln Leitung kontrollieren

Wartungseinheit

Fault No pressure display

Vid anslutning till en redan befintlig luftberedningsenhet av samma typ: 1. Placera en O-ring i utgångsanslutningen (P2) för det första aggregatet i kombinationen. 2. Montera ihop första och andra aggregatet i kombinationen (utgångsanslutning (P2) till ingångsanslutning (P1)) och skjut den bakre flänsens klackar in i skarvstyckets spår. 3. Skjut klämstyckets spår över den främre flänsens klackar och dra åt skruvarna hårt. 4. Upprepa vid behov.

  • M2- och M3-aggregat: 1. Placera O-ringar på båda sidor av skarvstycket. 2. Skjut in skarvstycket bakifrån och framåt i styrningarna till utgångsanslutningen (P2) hos första aggregatet i kombinationen. 3. Skjut in ingångsanslutningen (P1) för det andra aggregatet i skarvstycket. 4. Rikta in klämstycket med skruv mot hålet i skarvstycket, skruva i skruven och dra den hårt. 5. Upprepa detta i förekommande fall för samtliga ytterligare aggregat i kombinationen. 6. Placera en konsol på skarvstyckets baksida och dra båda skruvarna hårt. För montering av manometern: 1. Placera manometern i de befintliga anslutningsgängorna. 2. Alternativanslutningen är försluten med en blindplugg. 3. Flytta vid behov blindpluggen (inkl. tätning). 4. Skruva fast manometern och i förekommande fall blindpluggen.

Rengöring

( Eliminating faults

Mögliche Ursache Absperrventil geschlossen Druck nicht eingestellt

Filtret LFM-..-../.-B (1 µm) skall befinna sig före filtret LFM-..-../.-A (0,01 µm).

Rengöringsmedel Vatten eller tvållösning (max. + 60°C)

( Åtgärdande av fel

Possible cause Shut-off valve closed Pressure not set

Remedy Open shut-off valve Set pressure with pressure setting button

Manometer defective

Replace manometer

Low flow (operating pressure fails when compressed air is applied)

Filter element is dirty

Replace filter element

Restriction between shut-off valve and maintenance unit

Check piping

Druck steigt über den eingestellten Betriebsdruck

Ventilteller am Dichtsitz defekt

Festo zusenden

Pressure increases above set operating pressure

Defective valve face on sealing seat

Return to Festo

Hörbares Abblasen am Einstellknopf

Ventilsitz beschädigt

Festo zusenden

Exhaust can be heard at setting button

Valve seat damaged

Return to Festo

Fel Ingen tryckindikering

Dåligt luftflöde (vid luftförbrukning junker driftstrycket)

Möjlig orsak Avstängningsventilen stängd Tryck ej inställt

Åtgärd Öppna avstängningsventilen Ställ in trycket med tryckinställningsratten

Manometern defektByt manometerFilterinsats smutsigByt filterinsats

Förträngning mellan Kontrollera ledningen avstängningsventil och den kombinerade enheten

Trycket stiger över inställt driftstryck

Ventiltallrikens tätning defekt

Kontakta Festo för sercice på enheten

Hörbart läckage vid tryckinställningsratten

Ventilsätet skadat

Kontakta Festo för sercice på enheten

) Technische Daten

) Technical specifications

) Tekniska data

Max. zulässiger 21 bar (305 psi)/–10 °C (+14 °F)...+80 °C (+176 °F) (LR-/LRB-...) Vordruck p1 17 bar (247 psi)/–10 °C (+14 °F)...+80 °C (+176 °F) (LF-/LFR-...-.T/.U) und Temperatur- 12 bar (174 psi)/–10 °C (+14 °F)...+60 °C (+140 °F) (LF-/LFR-...-.R/.S) bereich 8 bar (116 psi)/–10 °C (+14 °F)...+60 °C (+140 °F) (...-M1-...-.R/.S) +1,5 °C (35 °F) ... +50 °C (122 °F) (LFM-...-A./ B.) +1,5 °C (35 °F) ... +30 °C (86 °F) (LFM-...-X.)

Permitted primary pressure max. p1 and temperature range

Max tillåtet ingående tryck P1 och temperaturintervall

Max. Arbeitsdruckbereich p2

siehe Typenschild

Max. working pressure range p2

see label

Max arbetstryckintervall P2

se skylt

Einbaulage

aufrecht stehend (± 5°), beliebig (LR-/ LRB-...)

Fitting position

standing upright (± 5°), any (LR-/ LRB-...)

Monteringsläge

upprättstående (± 5°) valfri (LR-/ LRB-...)

305 psi (21 bar)/+14 °F (–10 °C)...+176 °F (+80 °C) (LR-/LRB-...) 247 psi (17 bar)/+14 °F (–10 °C)...+176 °F (+80 °C) (LF-/LFR-...-.T/.U) 174 psi (12 bar)/+14 °F (–10 °C)...+140 °F (+60 °C) (LF-/LFR-...-.R/.S) 116 psi (8 bar)/+14 °F (–10 °C)...+140 °F (+60 °C) (...-M1-...-.R/.S) 35 °F (+1,5 °C) ... 122 °F (+50 °C) (LFM-...-A./ B.) 35 °F (+1,5 °C) ... 86 °F (+30 °C) (LFM-...-X.)

Manometeranschluß

G1/8 (bei LR-/ LFR-M1-G./.) G1/4 (bei LR-/ LFR-M2/3-G./.)

N1/8 (bei LR-/ LFR-M1-N./.) N1/4 (bei LR-/ LFR-M2/3-N./.)

Manometer connection

Filterfeinheit

40 µm (LF-/ LFR-...-E) 5 µm (LF-/ LFR-...-C) 1 µm (LFM-...-B)

0,01 µm (LFM-...-A) 0,003 µm (LFM-...-X)

Filter fineness 40 µm (LF-/ LFR-...-E) 5 µm (LF-/ LFR-...-C) 1 µm (LFM-...-B)

Medium Werkstoffe

Druckluft (bei LFM-... gefiltert, Filterfeinheit ≤ 40 µm) Gehäuse: Zink Innenteile: Acetal, Messing, Schutzkorb: ABS Edelstahl, Saitendraht Dichtungen: Nitrile Schale: Polycarbonat oder Zink Filtermedium: Gesintertes (M1 Größe: Nylon) Polypropylen Drehknopf: Acetal

9709 A

Medium Materials

G1/8 (at LR-/ LFR-M1-G./.) G1/4 (at LR-/ LFR-M2/3-G./.)

21 bar (305 psi)/–10 °C (+14 °F)...+80 °C (+176 °F) (LR-/LRB-...) 17 bar (247 psi)/–10 °C (+14 °F)...+80 °C (+176 °F) (LF-/LFR-...-.T/.U) 12 bar (174 psi)/–10 °C (+14 °F)...+60 °C (+140 °F) (LF-/LFR-...-.R/.S) 8 bar (116 psi)/–10 °C (+14 °F)...+60 °C (+140 °F) (...-M1-...-.R/.S) +1,5 °C (35 °F) ... +50 °C (122 °F) (LFM-...-A./ B.) +1,5 °C (35 °F) ... +30 °C (86 °F) (LFM-...-X.)

N1/8 (at LR-/ LFR-M1-N./.) N1/4 (at LR-/ LFR-M2/ 3-N./.)

Manometeranslutning

G1/8 (för LR-/ LFR-M1-G./.) G1/4 (för LR-/ LFR-M2/3-G./.)

N1/8 (för LR-/ LFR-M1-N./.) N1/4 (för LR-/ LFR-M2/3-N./.)

0.01 µm (LFM-...-A) 0.003 µm (LFM-...-X)

Filterfinhet

40 µm (LF-/ LFR-...-E) 5 µm (LF-/ LFR-...-C) 1 µm (LFM-...-B)

0,01 µm (LFM-...-A) 0,003 µm (LFM-...-X)

Medium Material

Tryckluft (för LFM-... filtrerad, filterfinhet ≤ 40 µm) hus: Zink kopp: Polycarbonat skyddslock: ABS eller zink inre detaljer: Acetal, (M1-storlek: nylon) mässing, filtermedium: Sintrad polypropylen rostfritt stål, tätningar: Nitrile pianotråd vridknapp: Acetal

compressed air (at LFM-... filtered, filter fineness ≤ 40 µm) Housing: Zinc Protective Interior parts: Acetal, brass, cover: ABS stainless steel, Bowl: Polycarbonate or music wire Zinc (Nylon in M1 Filter medium: Sintered series) Seals: Nitrile Knob: Acetal polypropylene

D/GB/S

Page 2 of Festo LF, LR and LFR Filter and Pressure Regulator Operating Instructions

The text of page 2, from the PDF itself

Postfach 6040 D-73726 Esslingen Telefon (07 11) 3 47-0

E

Quelltext: englisch Version: 9709 A Teile Nr.: 375 092

Instrucciones de utilización

FINotice d’utilisationIstruzioni per l’uso

Filtro, micro-filtro regulador de presión, filtro regulador Tipo LF-M.-..., LFM-M.-..., LR-M.-..., LRB-M.-..., LFR-M.-...

Filtre, Filtre fin Régulateur de pression, Vanne de régulation Type LF-M.-..., LFM-M.-..., LR-M.-..., LRB-M.-..., LFR-M.-...

Filtro, filtro-riduttore, riduttore di pressione, valvola di regolazione con filtro Tipo LF-M.-..., LFM-M.-..., LR-M.-..., LRB-M.-..., LFR-M.-...

El montaje y la puesta en funcionamiento, debe ser realizado exclusivamente por personal cualificado y siguiendo las instrucciones de utilización. Estos productos están diseñados para ser utilizados con aire comprimido. No deben utilizarse para ningún otro fluido (líquido o gas).

Montage et mise en service uniquement par du personnel agréé, conformément à la notice d’utilisation. Ce produit est destiné exclusivement à être utilisé avec de l’air comprimé. L’usage d’autres fluides n’est pas prévu (liquides ou gaz).

Montaggio e messa in servizio devono essere effettuati da personale qualificato ed autorizzato, in base alle istruzioni per l’uso. Questi prodotti sono stati specificamente progettati per l’impiego con aria compressa. L’eventuale loro impiego con fluidi di altro tipo (liquido o gassoso) è considerato improprio.

{ Aplicación El LFR-..., LR-..., LRB-... reduce la presión de entrada de aire a la presión de trabajo establecida y compensa las fluctuaciones de presión. El LF-..., LFM-..., LFR-... con separador de agua libera al aire comprimido de partículas de suciedad y de agua condensada.

; Condiciones para la utilización del producto

{ Utilisation Le LFR-..., LR-..., LRB-... régule la circulation d’air comprimé pour une pression de travail prédéfinie et compense les fluctuations de pression. Le LF-..., LFM-..., LFR-... avec séparateur d’eau élimine les particules de poussière et l’eau de condensation.

; Conditions de mise en oeuvre du produit

{ Funzionamento ed impiego I filtri LFR..., LR-..., LRB-... regolano la pressione dell’aria in ingresso in base alla pressione di lavoro nominale e assorbono le oscillazioni di pressione. I filtri LF-..., LFM..-..., LFR-... dotati di separatore d’acqua liberano l’aria compressa da particelle di sporcizia e dalla condensa.

; Condizioni di impiego

Para una utilización correcta y segura del producto, deben observarse en todo momento estas condiciones generales:

  • Observar los límites especificados para presiones, fuerzas, pares, masas, velocidades, temperaturas y tensiones eléctricas.
  • Respetar las condiciones ambientales imperantes.
  • Observar las directrices y normas de seguridad nacionales y locales establecidas.
  • Retirar todos los elementos auxiliares de transporte. Depositarlos en contenedores adecuados para reciclaje
  • Aplicar presión al sistema lentamente. Ello evitará movimientos bruscos e incontrolados.
  • No se permiten modificaciones no autorizadas del producto.

Remarques dont il convient de tenir compte d’une manière générale pour garantir un fonctionnement correct et en toute sécurité de ce produit:

  • Respectez les valeurs limites (p. ex. pressions, forces, couples, masses, vitesses, températures, tension électrique).
  • Tenez compte de l’environnement de mise en oeuvre.
  • Observez les prescriptions des organismes professionnels, des services de contrôle technique ou les réglementations nationales en vigueur.
  • Mettez votre installation en pression progressivement. Vous éviterez ainsi tout mouvement incontrôlé.
  • Utilisez le produit dans son état d’origine. N’y apportez aucune modification sans autorisation préalable.

= Montaje› ›= Montage› ›= Montaggio

  • Usar válvulas de cierre para despresurizar el sistema para montaje y mantenimiento
  • Utilisez des vannes d’isolement pour purger l’air avant toute intervention
  • Utilizzare valvole di intercettazione per poter togliere pressione all’impianto durante i

(p.ej. al cambiar el filtro).

  • Observar el sentido del flujo. Este se indica por flechas en el producto.
  • Dejar suficiente espacio por debajo del filtro (por lo menos 100 mm) para sustituir el filtro sucio.
  • Montar el LF-..., LFM..-..., LFR-... en posición vertical (±5º). En combinación con filtros finos y ultrafinos para formar un filtro LFM-...:
  • Observar el sentido del flujo en los microfiltros. El filtro LFM-..-../.-B (1 µm) debe hallarse antes que el filtro LFM-..-../.-A (0,01 µm).

de montage ou d’entretien (p. ex. remplacement de la cartouche de filtre) de l’installation.

  • Respectez le sens d’écoulement. Celui-ci est indiqué par une flèche visible sur le produit.
  • Prévoyez la place nécessaire en dessous de la cuve de filtre (min. 100 mm) pour pouvoir changer le filtre.
  • Positionnez le LF-..., LFM..-..., LFR-... à la verticale (±5º). En cas d’assemblage d’un filtre fin sur un filtre LFM-...:
  • Respectez l’ordre de montage et le sens d’écoulement du filtre fin. Le filtre LFM-..-../.-B (1 µm) doit être situé en amont du filtre LFM-..-../.-A (0,01 µm).

Montaje junto con otras unidades de mantenimiento del mismo tipo:

  • Unidades M1: 1. Instalar una junta tórica en la salida (P2) de la primera unidad de la serie. 2. Unir la primera y la segunda unidad de la serie (la salida (P2) con la entrada (P1)) y situar las bridas de fijación en la ranura en T. 3. Situar la ranura de fijación frente a la brida frontal e instalar los tornillos firmemente. 4. Repetir según sea necesario.
  • Unidades M2 y M3: 1. Instalar las juntas tóricas (2 en cada unidad) en ambos lados de la pieza de unión en T. 2. Deslizar la pieza de unión en T desde atrás y hacia el frente, por las guías en la salida (P2) de la 1ª unidad de la serie. 3. Deslizar el lado de la conexión de entrada (P1) de la segunda unidad en la pieza de unión. 4. Alinear el retenedor de la pieza de unión en T, encarando el agujero y apretar el tornillo. 5. Repetir según sea necesario para cada unidad de la serie. 6. Situar el soporte tras la pieza de unión en T y montar los tornillos repitiendo según fuera necesario. Fijación del manómetro: 1. Colocar el manómetro en la conexión roscada existente. 2. La conexión alternativa se cierra con un tapón ciego. 3. Si es necesario, reemplazar el tapón ciego (junta incluída). 4. Apretar el manómetro y, si es necesario, el tapón ciego.

% Puesta a punto Ajuste del regulador LR-..., LRB-..., LFR-...: 1. Aplicar presión lentamente a todo el sistema. 2. Tirar hacia arriba del botón de ajuste (alejándolo del cuerpo). 3. Girar el botón hasta que el manómetro indique la presión deseada. La presión de entrada debe ser por lo menos 1 bar superior a la de salida. 4. Presionar el botón de ajuste hacia abajo (hacia el cuerpo) para asegurarlo contra giros no intencionados.

& Mantenimiento y cuidados Si el nivel de condensados alcanza el nivel „MAX“ en el vaso:

  • Abrir el tornillo de purga girándolo en sentido antihorario visto desde abajo. Entonces puede descargarse el condensado. Si disminuye el caudal con el mismo ajuste de la presión:
  • Reemplazar el elemento filtrante, como mínimo cada 12 meses. 1. Descargar el aire del sistema y de la unidad 2. Desenroscar el vaso del filtro en sentido antihorario mirando desde abajo. 3. Desenroscar el retenedor del filtro en sentido antihorario mirando desde abajo. 4. Reemplazar el elemento filtrante. 5. Volver a montar las piezas en orden inverso al del desmontaje. 6. Volver a poner a punto, como se describe en la sección „Puesta a punto“. Mantenimiento del regulador cada seis meses.
  • Desmontar el regulador.
  • Inspeccionar el diafragma y las juntas.
  • Inspeccionar, limpiar y lubricar el conjunto de la válvula y la junta tórica.
  • Reemplazar las piezas desgastadas o deterioradas Limpieza
  • Usar solamente los agentes limpiadores especificados:

Componente Vaso del filtro

Agente limpiador Agua jabonosa (max. +60°C)

En cas d’assemblage sur une unité de conditionnement d’air de même type déjà en service:

  • Série M1: 1. Placez un joint torique sur le raccord de sortie (P2) du premier appareil de la combinaison. 2. Assemblez le premier appareil avec le deuxième (raccord de sortie (P2) avec le raccord d’entrée (P1)) et introduisez l’ergot de la plaque de raccordement arrière dans la rainure de la pièce de liaison. 3. Amenez la rainure de la pièce de serrage au dessus de l’ergot de la plaque de raccordement avant puis serrez les vis. 4. Renouvelez l’opération si nécessaire.
  • Séries M2 et M3: 1. Placez des joints toriques des deux côtés de la pièce de liaison. 2. Introduisez d’arrière en avant la pièce de liaison dans les guidages du raccord de sortie (P2) du premier appareil de la combinaison. 3. Introduisez le raccord d’entrée (P1) du deuxième appareil dans la pièce de liaison. 4. Positionnez la pièce de serrage avec vis sur le trou de la pièce de liaison. Vissez puis serrez la vis. 5. Renouvelez le cas échéant l’opération pour les autres appareils de la combinaison. 6. Placez une équerre de fixation à l’arrière de la pièce de liaison et bloquez les deux pièces ensemble. Montage du manomètre: 1. Mettez le manomètre en place sur la sortie filetée de raccordement prévue. 2. L’autre branchement reste obturé par un bouchon. 3. Inversez si nécessaire la position du bouchon (y compris le joint d’étanchéité). 4. Serrez le manomètre et le bouchon.

% Mise en service Réglage du régulateur LR-..., LRB-..., LFR-...: 1. Mettez l’installation en pression progressivement. 2. Tirez le bouton de réglage de la pression vers le haut (à l’opposé du corps). 3. Tournez le bouton de réglage jusqu’à ce que le manomètre indique la pression désirée. La pression d’entrée doit être supérieure d’au moins 1 bar à la pression de sortie. 4. Poussez le bouton de réglage vers le bas (vers le corps) pour le bloquer en rotation.

& Maintenance et entretien Lorsque le niveau du condensat dans la cuve atteint le repère ”MAX”:

  • Ouvrez la vis de purge en la tournant dans le sens antihoraire (vu de dessous). Laissez s’écouler le condensat. Si l’écoulement se réduit alors que la pression n’est pas modifiée:
  • Remplacez la cartouche filtrante au moins tous les 12 mois. 1. Purgez l’installation et l’appareil. 2. Dévissez la cuve dans le sens anti-horaire (vu de dessous). 3. Dévissez le support de filtre dans le sens anti-horaire (vu de dessous). 4. Remplacez la cartouche filtrante. 5. Remontez les différentes pièces dans l’ordre inverse. 6. Procédez à la remise en service conformément au chapitre „Mise en service“. Entretien semestriel du régulateur.
  • Démontez complètement le régulateur.
  • Contrôlez la membrane et l’étanchéité.
  • Contrôlez l’état de la valve et du joint torique, la nettoyer et la lubrifier.
  • Remplacez les pièces usées ou abîmées. Nettoyage Composant Cuve du filtre

Produit de nettoyage Eau ou eau savonneuse (max. +60°C)

( Eliminación de fallos

( Dépannage

Fallo No indica presión

Panne Pas d’indication de pression

Bajo caudal (falla la presióncuando hay consumo de aire comprimido) La presión sube por encima de la establecida

Manómetro defectuoso

Reemplazar el manómetro

Elemento filtrante sucio

Reemplazar el elemento filtrante

Estrangulación entre la Verificar las conducciones válvula de cierre y la unidad de mantenimiento

lavori di montaggio e manutenzione (p.es. durante la sostituzione del filtro).

  • Prestare attenzione alla direzione di flusso indicata dalla freccia.
  • Lasciare uno spazio sotto la tazza del filtro sufficiente per sostituire il filtro (almeno

100 mm).

  • Regolare i filtri LF-..., LFM..-..., LFR-... tenendoli in posizione verticale (±5º).

In caso di combinazione di filtri fini e microfiltri:

  • Prestare attenzione alla successione dei microfiltri e alla direzione del flusso.

Il filtro LFM-..-../.-B (1 µm) deve essere posto a monte del filtro LFM-..-../.-A 0,01 µm). In caso di combinazione con un’altra unità di manutenzione dello stesso tipo:

  • Unità M1:

1. Posizionare l’O-ring nell’attacco di scarico (P2) della prima unità del la combinazione. 2. Collegare la prima e la seconda unità (raccordare l’attacco di scarico (P2) della prima all’attacco di alimentazione (P1) della seconda) e risistemare i tasselli della flangia posteriore nella scanalatura dell’elemento di fissaggio. 3. Posizionare la scanalatura dell’elemento di serragio al di sopra dei tasselli della flangia anteriore e serrare le viti. 4. Ripetere la serie di operazioni per il numero di volte richiesto.

  • Unità M2 e M3: 1. Inserire gli O-ring a entrambe le estremità del tubo di collegamento (2 per ogni lato). 2. Innestare da dietro il tubo nelle apposite guide dell’attacco di scarico (P2) della prima unità dela combinazione. 3. Collegare l’attacco di alimentazione (P1) della seconda unità al tubo. 4. Allineare l’elemento di serraggio al tubo di collegamento inserendo la vite del primo nel foro del secondo, quindi serrare la vite. 5. Ripetere la serie di operazioni per il numero di volte richiesto. 6. Posizionare la squadretta di fissaggio sul lato posteriore e serrare entrambe le viti. Montaggio del manometro: 1. Fissare il manometro nell’apposito raccordo filettato. 2. L’attacco alternativo è chiuso con un tappo a vite. 3. Allentare eventualmente il tappo a vite (e la rispettiva guarnizione). 4. Fissare il manometro e stringere eventualmente anche il tappo a vite.

% Messa in servizio Regolazione dei filtri LR-..., LRB-..., LFR-..: 1. Alimentare l’impianto gradualmente. 2. Tirare la manopola di regolazione verso l’alto (in direzione opposta al corpo). 3. Ruotare la manopola di regolazione finché il manometro indica la pressione desiderata. La pressione all’ingresso deve essere superiore alla pressione di uscita di almeno 1 bar. 4. Premere la manopola di regolazione verso il basso (in direzione del corpo), allo scopo di evitarne lo spostamento accidentale.

& Manutenzione e pulizia Se la condensa raggiunge il livello “MAX” nella tazza:

  • Aprire la vite di scarico ruotandola in senso antiorario (vista dal basso) per consentire il deflusso della condensa. In caso di riduzione della portata nonostante la taratura di pressione sia invariata:
  • Sostituire la cartuccia filtrante almeno ogni 12 mesi. 1. Scaricare il sistema e il dispositivo. 2. Svitare la tazza del filtro ruotandola in senso antiorario (vista dal basso). 3. Svitare il supporto del filtro ruotandolo in senso antiorario (visto dal basso). 4. Sostituire la cartuccia filtrante. 5. Rimontare i particolari in ordine inverso. 6. Ripetere la messa in servizio come indicato nel capitolo “Messa in servizio”. Effettuare la manutenzione del riduttore ogni sei mesi.
  • Disassemblare il riduttore.
  • Controllare la membrana e le guarnizioni.
  • Controllare, pulire e lubrificare il gruppo valvole e l’O-ring.
  • Sostituire le parti usurate o danneggiate. Pulizia
  • Utilizzare esclusivamente i detergenti indicati:
  • Utilisez uniquement les produits de nettoyage préconisés:

Causa posible Remedio Válvula de entrada cerrada Abrir la válvula de entrada Presión no ajustada Ajustar la presión con el botón de ajuste

Per un impiego corretto e sicuro del prodotto devono essere sempre osservate le seguenti indicazioni generali:

  • Rispettare i valori-limite indicati (p. es. pressioni, forze, momenti, masse, velocità, temperature e tensioni elettriche).
  • Tenere conto delle condizioni ambientali esistenti.
  • Attenersi alle prescrizioni delle associazioni di categoria nonché alle disposizioni e alle norme di sicurezza nazionali e locali.
  • L’impianto deve essere alimentato gradualmente, onde evitare il verificarsi di movimenti incontrollati.
  • Il prodotto va utilizzato nelle condizioni originali, senza apportare modifiche arbitrarie.

Ecoulement réduit (la pression chute dès que de l’air comprimé est utilisé)

Componente Tazza filtro

Detergente Acqua o acqua saponata (max. + 60°C)

( Eliminazione guasti Cause possible Remède Vanne d’isolement fermée Ouvrir la vanne d’isolement Pression non réglée Régler la pression à l’aide du bouton de réglage Manomètre défectueux

Remplacer le manomètre

Cartouche filtrante encrassée

Remplacer la cartouche filtrante

Etranglement entre la Contrôler les conduites vanne d’isolement et l’unité de conditionnement

Guasto Nessun valore di pressione visualizzato

Portata bassa (improvviso calo della pressione di esercizio in corrispondenza dell’utilizzo di aria compressa)

Possibile causa Valvola di intercettazione chiusa Pressione non tarata

Rimedio Aprire la valvola di intercettazione. Tarare la pressione agendo sulla relativa manopola.

Manometro difettoso

Sostituire il manometro.

Cartuccia filtrante sporca Sostituire la cartuccia filtrante. Strozzatura tra la valvola Controllare il tubo. di intercettazione e l’unità di manutenzione

Válvula defectuosa en el asiento de la junta

Devolver a Festo

La pression dépasse la valeur préréglée

Clapet de soupape défectueux

Envoyer l’appareil chez Festo

La pressione supera la Cono della sede di tenuta Spedire il particolare a Festo. pressione di esercizio tarata. della valvola difettoso

Puede oírse ruido de escape Asiento de la válvula en el lado del botón de ajuste dañado

Devolver a Festo

Sifflement au niveau du bouton de réglage

Siège de soupape défectueux

Envoyer l’appareil chez Festo

Perdita udibile dalla manopola di regolazione

Sede valvola difettosa

) Especificaciones técnicas

) Caractéristiques techniques

) Dati tecnici

Presión primaria 21 bar (305 psi)/–10 °C (+14 °F)...+80 °C (+176 °F) (LR-/LRB-...) permitida 17 bar (247 psi)/–10 °C (+14 °F)...+80 °C (+176 °F) (LF-/LFR-...-.T/.U) máx. p1 12 bar (174 psi)/–10 °C (+14 °F)...+60 °C (+140 °F) (LF-/LFR-...-.R/.S) y margen de 8 bar (116 psi)/–10 °C (+14 °F)...+60 °C (+140 °F) (...-M1-...-.R/.S) temperatura +1,5 °C (35 °F) ... +50 °C (122 °F) (LFM-...-A./ B.) +1,5 °C (35 °F) ... +30 °C (86 °F) (LFM-...-X.)

Pression 21 bar (305 psi)/–10 °C (+14 °F)...+80 °C (+176 °F) (LR-/LRB-...) d’alimentation 17 bar (247 psi)/–10 °C (+14 °F)...+80 °C (+176 °F) (LF-/LFR-...-.T/.U) adm. p1 12 bar (174 psi)/–10 °C (+14 °F)...+60 °C (+140 °F) (LF-/LFR-...-.R/.S) max. et plage 8 bar / -10°C ... +60°C (...-M1-...-.R/.S) de températures +1,5 °C (35 °F) ... +50 °C (122 °F) (LFM-...-A./ B.) +1,5 °C (35 °F) ... +30 °C (86 °F) (LFM-...-X.)

Max. pressione a monte p1 e intervallo di temperatura ammissibili

Margen de presión máx. p2

ver etiqueta

Pression de travail max. p2

voir plaque signalétique

Max. interv. della pressione di lavoro p2 vedi targhetta

Posición de montaje

vertical (± 5°), indiferente (LR-/ LRB-...)

Position de montage

verticale (± 5°), indifférente (LR-/ LRB-...)

Posizione di montaggio

Spedire il particolare a Festo.

21 bar (305 psi)/–10 °C (+14 °F)...+80 °C (+176 °F) (LR-/LRB-...) 17 bar (247 psi)/–10 °C (+14 °F)...+80 °C (+176 °F) (LF-/LFR-...-.T/.U) 12 bar (174 psi)/–10 °C (+14 °F)...+60 °C (+140 °F) (LF-/LFR-...-.R/.S) 8 bar (116 psi)/–10 °C (+14 °F)...+60 °C (+140 °F) (...-M1-...-.R/.S) +1,5 °C (35 °F) ... +50 °C (122 °F) (LFM-...-A./ B.) +1,5 °C (35 °F) ... +30 °C (86 °F) (LFM-...-X.) verticale (± 5°), qualsiasi (LR-/ LRB-...)

Conexión G1/8 (en LR-/ LFR-M1-G./.) del manómetro G1/4 (en LR-/ LFR-M2/3-G./.)

N1/8 (en LR-/ LFR-M1-N./.) N1/4 (en LR-/ LFR-M2/ 3-N./.)

Raccord du manomètre

G1/8 (pour LR-/LFR-M1-G./.) N1/8 (pour LR-/LFR-M1-N./.) G1/4 (pour LR-/LFR-M2/3-G./.) N1/4 (pour LR-/LFR-M2/3-N./.)

Collegamento G1/8 (per LR-/ LFR-M1-G./.) N1/8 (per LR-/ LFR-M1-N./.) manometro G1/4 (per LR-/ LFR-M2/3-G./.) N1/4 (per LR-/ LFR-M2/3-N./.)

Finura del filtro

40 µm (LF-/ LFR-...-E) 5 µm (LF-/ LFR-...-C) 1 µm (LFM-...-B)

0.01 µm (LFM-...-A) 0.003 µm (LFM-...-X)

Finesse de filtre

40 µm (LF-/LFR-...-E) 5 µm (LF-/LFR-...-C) 1 µm (LFM-...-B)

Capacità filtrante

40 µm (LF-/ LFR-...-E) 5 µm (LF-/ LFR-...-C) 1 µm (LFM-...-B)

Medio

aire comprimido (en LFM-... filtrado, finura del filtro ≤ 40 µm)

Fluide

Air comprimé (filtré pour la LFM-..., finesse de filtre ≤ 40 µm)

Fluido

aria compressa (per LFM-... filtrata, capacità filtrante ≤ 40 µm)

Materiales

Cuerpo: Piezas interiores
Matériaux

corps: panier de protection: pièces intérieures: joints:

Materiali

corpo: protezione: elementi interni:

Elemento filtrante: 9709 A

Zinc Acetal, latón, acero inoxidable, cuerda de piano Polipropileno sinterizado

Tapa de protección: Vaso: Juntas: Pomo:

ABS Policarbonato o Zinc (Nylon en la serie M1) Nitrilo Acetal

0,01 µm (LFM-...-A) 0,003 µm (LFM-...-X)

Zinc

cuve
ABS Acétal, laiton, inox, acier au Nitrile

cartouche de filtre: bouton de réglage:

Polycarbonate ou zinc (série MINI : nylon) Polypropylène carbone fritté Acétal

zinco ABS acetale, ottone, acciaio inossidabile, filo vibrante

0,01 µm (LFM-...-A) 0,003 µm (LFM-...-X)

tazza: cartuccia filtrante: guarnizioni: manopola:

policarbonato o zinco (unità M1: nylon) polipropilene sinterizzato nitrile acetale E/F/I