Spec sheet · Datalogic
Datalogic MX4000 Spec Sheet
Spec sheet2 pagesPDF 294 KB
Both pages are below, each with its text.
Covers · 1 model
The models it covers
From the sheet · read page by page
Key facts from this sheet
Each line names its page in the PDF.
A two-page Datalogic spec sheet for the MX4000 industrial multiplexer, a data concentrator that collects bar code data from a network of Datalogic readers and passes it to a host or industrial bus. It lists the four versions with their model codes and order numbers, the interfaces, I/O, display, size and environment figures.
- Device
- Industrial multiplexer for high speed data collection from up to 32 reading stations p. 1
- Reader network
- RS485 or LonWorks bus p. 1
- Host interface
- Programmable RS232/RS485 polled or non-polled, 20 mA current loop; up to 115.2 Kbauds p. 2
- Fieldbus options
- Profibus-DP and Interbus-S versions; DeviceNet, Remote I/O, ModBus Plus, ModBus RTU, CANOpen and others through optional interface boards p. 2
- Auxiliary port
- RS232, up to 19.2 Kbauds p. 2
- Digital I/O
- 2 optocoupled NPN/PNP inputs; 3 NPN transistor outputs (open collector/emitter) p. 2
- Display and keypad
- Backlit LCD, 20 characters on 4 lines; 4 membrane keys; 7 communication status LEDs p. 2
- Power consumption
- 6W maximum p. 2
- Size and weight
- 240 x 200 x 66 mm (9.45 x 7.87 x 2.6 in); 1.95 Kg (4.29 lb); aluminium case p. 2
- Temperature
- Operating 0 to 55 °C (32 to 131 °F); storage -20 to 70 °C (-4 to 158 °F); humidity 90 % non condensing p. 2
- Versions
- RS485 network/host std, RS485 network/Profibus-DP, RS485 network/Interbus-S, LonWorks network/host std p. 2
- Model codes
- MX4000-1000, MX4000-1100, MX4000-1200, MX4000-2000 p. 2
- Order numbers
- 935151000, 935151010, 935151020, 935151030 p. 2
What this sheet walks you through
- Collecting data from a multi-station or 360 degree multi-head reading system p. 1
- Monitoring each scanner and the network status for maintenance p. 1
- Connecting the reading stations, host and auxiliary RS232 port p. 2
Good to know
- Profibus-DP and Interbus-S need their specific models; other buses connect through standard interface boards. p. 1
Questions this sheet answers
How many scanners can a Datalogic MX4000 connect?
It collects data from up to 32 reading stations over an RS485 or LonWorks network. p. 1
What host interfaces does the MX4000 support?
A programmable RS232/RS485 or 20 mA current loop host port up to 115.2 Kbauds, with Profibus-DP and Interbus-S versions and other buses through optional boards. p. 2
What are the MX4000 dimensions and weight?
240 x 200 x 66 mm (9.45 x 7.87 x 2.6 in) and 1.95 Kg (4.29 lb). p. 2
The file
Size and text
Every page · 2
Read it here
Each page as it is printed, and its words beside it, so a phone can search and copy them.
Page1of 2
Open in the PDF
The text of page 1, from the PDF itself
MX4000
U N AT T E N D E D S C A N N I N G S Y S T E M S
MX4000
Industrial Multiplexer FEATURES l
High speed data collection from up to 32 reading stations
l
RS485 or LonWorks Bus for data collection
l
Serial, Interbus-S, Profibus-DP host interfaces
l
Multiplexer set up through WINHOST™ or backlit display and keypad
l
WINHOST™ remote scanner control and set up
l
Rugged industrial housing
APPLICATIONS lParcel sorting systemsl
Material tracking systems
l
Work-in-progress control
l
Quality control
GENERAL DESCRIPTION Datalogic’s data concentrator, MX4000, offers high communication performance, excellent connectivity, and advanced software tools for monitoring and control of data collection networks. MX4000 has been designed for high speed data collection in a multidrop network of Datalogic bar code readers. Through MX4000, a multi-station reading system or a single reading station in a multi-head configuration for 360° reading around the conveyor, can be realized in a very simple way. Thanks to a multitasking application program, the MX4000 unit collects data, controls the status of the readers and elaborates statistics. MX4000 is fitted with 2 serial interfaces for communication with the host computer and makes connection to the most popular industrial Buses very easy. Specific models for the most popular Profibus-DP and Interbus-S are available. Virtually all industrial buses can be connected through standard interface boards. MX4000 is easily configured by the WINHOST™ software program. Through the MX4000, WINHOST™ can perform set up procedures on the connected scanners with benefits in time saving, reliability and flexibility. MX4000 allows complete performance monitoring of each scanner and controls the network’s status, providing very useful information for maintenance service. Datalogic’s data concentrator is equipped with a keypad, backlit display and rugged industrial housing resistant to harsh enviroments. MX4000 is the ideal solution for today’s requirements, and opens a window for tomorrow’s needs.
Page2of 2
Open in the PDF
The text of page 2, from the PDF itself
DESCRIPTION RS485 NETWORK/HOST STD RS485 NETWORK/PROFIBUS-DP RS485 NETWORK/INTERBUS-S LONWORKS NETWORK/HOST STD
ORDER NO. 935151000 935151010 935151020 935151030
DIMENSIONS10 to 30 VdcMAX. CONSUMPTION6W
HOST STANDARD INTERFACE
Programmable RS232 /RS485 Polled - non polled /20 mA C.L. /Up to 115.2 Kbauds
PROFIBUS INTERFACEStandard - DP protocolINTERBUS INTERFACE
Standard Interbus-S protocol
OPTIONAL BUS INTERFACE
DeviceNet, Remote I/O, ModBus Plus, ModBus RTU, CANOpen and others (through optional interface boards)
AUXILIARY INTERFACE
RS232/Up to 19.2 Kbauds
INPUT SIGNAL
2 digital inputs (Optocoupled NPN/PNP transistor)
OUTPUT SIGNAL
3 digital outputs (NPN transistor, open collector / emitter)
LED INDICATORS
7 communication status LEDs
KEYPAD4 membrane keysDISPLAY
Backlit LCD, 20 characters on 4 lines
222 8.749 0.3530 1.18160 6.2910.8 0.42POWER SUPPLY9 0.35SPECIFICATIONS142 5.59
MODEL MX4000-1000 MX4000-1100 MX4000-1200 MX4000-2000
CONFIGURATION METHOD Manual Through the keypad Automatic Through the serial interface (WINHOST™) DIMENSIONS
240 x 200 x 66 mm (9.45 x 7.87 x 2.6 in)
WEIGHT1.95 Kg (4.29 lb)CASE MATERIALAluminium66 2.5946.85 1.84 18.5 0.72mm inchCONNECTIONS
RS485 Aux. RS232 Control Station
Main/Bus MX4000
Host
OPERATING TEMPERATURE 0 to 55 °C (32 to 131 °F) STORAGE TEMPERATURE -20 to 70 °C (-4 to 158 °F) HUMIDITY
90 % non condensing
VIBRATION RESISTANCE
IEC 68-2-6 test FC 1.5 mm; 10 to 55 Hz; 2 hours on each axis
PROTECTION CLASS
Control Station
IEC 68-2-27 test EA 30 G; 11 ms; 3 shocks on each axis
Main/Bus MX4000 Host
IP58 (IP65 optional)
Product and company names and logos referenced may be either trademarks or registered trademarks of their respective companies.
Datalogic S.p.A.
Italy Corporate Headquarters Tel. +39 051/3147011 Fax +39 051/726562 info@datalogic.it Sales Italy Tel. +39 051/3147300 Fax +39 051/726562 venditeitalia@datalogic.it Sales International
(Central and South America, Far East, Middle East - Africa)
Tel. +39 041/5986511 Fax +39 041/5986550 sales-intl@datalogic.it
We reserve the right to make modifications and improvements
Australia Datalogic PTY LTD. Tel. +61 3/95589299 Fax +61 3/95589233 sales@datalogic.com.au
Austria Datalogic Handelges MBH Tel. +43 2236/258820 Fax +43 2236/258825 office@datalogic.co.at
Denmark Datalogic AB Tel. +45 44/209970 Fax +45 44/209972 info@datalogic.se
France Datalogic France S.A. Tel. +33 1/60921111 Fax +33 1/60921340 dlfrance@worldnet.fr
Germany Datalogic GmbH Tel. +49 7026/6080 Fax +49 7026/5746 info@datalogic.de
Japan Izumi Datalogic Co., Ltd. Tel. +81 78/2723400 Fax +81 78/2722003 idlmarke@izumi-datalogic.co.jp
Netherlands Datalogic Optic Electronics BV Tel. +31 346/572888 Fax +31 346/568736 info@datalogic.nl
Spain Datalogic España Tel. +34 93/4335253 Fax +34 93/4335254 datalogic@sei.es
Sweden Datalogic AB Tel. +46 40/385000 Fax +46 40/385001 info@datalogic.se
United Kingdom Datalogic UK Ltd. Tel. +44 1582/464900 Fax +44 1582/464999 enquiries@datalogic.demon.co.uk
U.S.A. Datalogic Inc. Tel. +1 859/6897000 Fax +1 859/3344970 info@datalogic.com
www.datalogic.com
Datalogic Quality Partner
9C0003030SHOCK RESISTANCEAux. RS232
Datalogic Communication Division Printed in Italy in May 2001
MX4000
MODELS AND ACCESSORIES