Spec sheet · Datalogic
Datalogic MC-8000 / MC-P080 Spec Sheet
Spec sheet2 pagesPDF 126 KB
Both pages are below, each with its text.
Covers · 1 model
The models it covers
From the sheet · read page by page
Key facts from this sheet
Each line names its page in the PDF.
Two-page Datalogic quick reference (820002090 Rev. A) for the MC-8000 Multi-Slot Battery Charger, a 4-slot charger for PowerScan M8300 battery packs; it names only the MC-8000. It gives the technical features, the power supply, connection, charging and the charge state LED.
- What it is
- Multi-slot battery charger with 4 slots for PowerScan M8300 battery packs p. 1
- Power
- 10-30 VDC, max 35 W p. 1
- Charge time
- 2150 mAh Li-Ion battery: max. 4 hours p. 1
- Power supply
- FPS18 Universal Power Supply p. 1
- Power source rating
- Class 2 or LPS power source rated 10 - 30 V DC, minimum 35 W p. 2
- Size and weight
- 205 x 97 x 112 mm (8.07 x 3.81 x 4.4 in); 460 g p. 1
- LEDs
- Yellow LED for power on; Red/Green LED for charging state p. 1
What this sheet walks you through
- Connecting the power supply p. 1
- Charging a battery pack p. 2
- Reading the battery charging state LED p. 2
Good to know
- Charging slows above 30 °C or when the battery is extremely low. p. 2
- The charger cannot signal every kind of battery failure. p. 2
- The sheet states it meets FCC Part 15 Class A limits, meant for a commercial environment. p. 2
Questions this sheet answers
What batteries does the MC-8000 charge?
PowerScan M8300 battery packs, up to four at a time. p. 1
How long does the MC-8000 take to charge a battery?
At most 4 hours for a 2150 mAh Li-Ion battery. p. 1
What power supply does the MC-8000 use?
The FPS18 Universal Power Supply; the charger takes 10-30 VDC, max 35 W. p. 1
The file
Size and text
Every page · 2
Read it here
Each page as it is printed, and its words beside it, so a phone can search and copy them.
Page1of 2
Open in the PDF
The text of page 1, from the PDF itself
MC-8000 MULTI-SLOT BATTERY CHARGER The MC-8000 is a Multi-Slot Battery Charger with 4 slots. It allows you to charge the ® PowerScan M8300 battery packs.
MULTI-SLOT BATTERY CHARGER MC-8000
Power on LED
The MC-8000 is a Multi-Slot Battery Charger with 4 slots. It allows you to charge the PowerScan® M8300 battery packs.
Power on LED
Battery Charging State LED
Battery Charging State LED
TECHNICAL FEATURES
TECHNICAL FEATURES ELECTRICAL Power supply Max consumption Charge time ENVIRONMENTAL Working temperature Storage temperature Humidity
10-30 VDC max 35 W 2150 mAh Li-Ion battery: max. 4 hours
PHYSICAL Dimensions 205 x 97 x 112 mm (8.07 x 3.81 x 4.4 in) Weight 460 g
ELECTRICAL Power supply Max consumption Charge time
LEDs
ENVIRONMENTAL Working temperature
0° to +40 °C +32° to +104 °F -20° to +70 °C -4° to +158 °F 90% non-condensing
Yellow LED (power on) Red/Green LED (charging state)
Storage temperature Humidity
10-30 VDC max 35 W 2150 mAh Li-Ion battery: max. 4 hours
PHYSICAL Dimensions 205 x 97 x 112 mm (8.07 x 3.81 x 4.4 in) Weight 460 g LEDs
0° to +40 °C +32° to +104 °F -20° to +70 °C -4° to +158 °F 90% non-condensing
Yellow LED (power on) Red/Green LED (charging state)
ACCESSORIES
ACCESSORIES
FPS18 Universal Power Supply.
FPS18 Universal Power Supply.
CONNECTIONS
CONNECTIONS
Plug the power supply into the connector positioned on the MC-8000 base. Then plug the power supply into a socket.
Plug the power supply into the connector positioned on the MC-8000 base. Then plug the power supply into a socket.
820002090 (Rev. A)
820002090 (Rev. A)
Page2of 2
Open in the PDF
The text of page 2, from the PDF itself
USING MC-8000 ‰USING MC-8000Charge Function‰
Correctly insert the battery pack into one of the free slots; charging starts automatically.
‰
Battery Charging State LED Description
LED State Off Red Green Orange blinking Red/Green Alternatively blinking
Charging State Empty slot Charging End of charge Battery failure - replace battery Charging Error - see Ref. Manual
The charge takes place slowly if the temperature rises above 30 °C or if the battery is extremely low.
Charge Function
Correctly insert the battery pack into one of the free slots; charging starts automatically.
‰
Battery Charging State LED Description
LED State Off Red Green Orange blinking Red/Green Alternatively blinking
The charge takes place slowly if the temperature rises above 30 °C or if the battery is extremely low.
Not all types of battery failures can be signaled by the battery charger. NOTE
Charging State Empty slot Charging End of charge Battery failure - replace battery Charging Error - see Ref. Manual
Not all types of battery failures can be signaled by the battery charger. NOTE
FCC COMPLIANCE
FCC COMPLIANCE
Modifications or changes to this equipment without the expressed written approval of Datalogic could void the authority to use this equipment.
Modifications or changes to this equipment without the expressed written approval of Datalogic could void the authority to use this equipment.
This device complies with PART 15 of the FCC Rules. Operation is subject to the following two conditions: (1)This device may not cause harmful interference, and (2) this device must accept any interference received, including interference which may cause undesired operation.
This device complies with PART 15 of the FCC Rules. Operation is subject to the following two conditions: (1)This device may not cause harmful interference, and (2) this device must accept any interference received, including interference which may cause undesired operation.
This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense.
This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense.
POWER SUPPLY
POWER SUPPLY
This device is intended to be supplied by a UL Listed/CSA Certified Power Unit marked "Class 2" or LPS power source rated 10 - 30 V DC, minimum 35 W, which supplies power directly to the device.
This device is intended to be supplied by a UL Listed/CSA Certified Power Unit marked "Class 2" or LPS power source rated 10 - 30 V DC, minimum 35 W, which supplies power directly to the device.
WEEE COMPLIANCE
WEEE COMPLIANCE
For information about the disposal of Waste Electrical and Electronic Equipment (WEEE), please refer to the website at www.scanning.datalogic.com.
For information about the disposal of Waste Electrical and Electronic Equipment (WEEE), please refer to the website at www.scanning.datalogic.com.