DX8200A Reference Manual: GUIDE TO INSTALLATION

Pages 14 to 16 of 97, from DX8200A Reference Manual

The original document is the PDF (6.2 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.

Filed in the catalog under the Datalogic DX8200

Page 14

GUIDE TO INSTALLATION POINT-TO-POINT INSTALLATION The following can be used as a checklist to verify all the necessary steps to complete installation of the DX8200A scanner. 1) Read all information in the section “Safety Regulations” at the beginning of this manual. 2) Correctly mount the scanner according to the information in par. 2.2.1 and position it at the correct reading distance as shown in par. 4.4. 3) Make electrical connections to your DX8200A scanner by: a) Connecting the DX8200A scanner to the C-BOX 100 by means of one of the CAB-601X cables provided as accessory (see par. 1.5). b) Providing correct and complete system cabling through the C-BOX 100 according to the signals necessary for the layout of your application (trigger, inputs, outputs). •

Layout: Point-to-Point, Pass Through, RS232 Master/Slave, Fieldbus. See subparagraphs under 2.5 for reference.

•

Cabling: Power, Main Serial Interface – RS232, RS485 Half Duplex, RS485 Full Duplex, 20 mA Current Loop, Auxiliary Interface, Inputs, Outputs, etc -. For further details, see all sub-paragraphs under par. 2.3.

4) Configure the DX8200A scanner by installing and running the Genius™ configuration program from the CD-ROM provided. The main steps are: •

Select the codes to be read

•

Set-up the communication parameters

•

When PackTrack™ is required, set the PS Offset and Position parameters

•

Define data formatting parameters

Fine tuning of the scanner position for barcode reading can be accomplished by performing a test through the SPY configuration tool in Genius™. NOTE

5) Exit the configuration program and run your application. The installation is now complete.

xii

Page 15

MASTER/SLAVE LONWORKS INSTALLATION The following can be used as a checklist to verify all the steps necessary to complete installation of the DX8200A scanner in a Master/Slave Lonworks network. 1) Read all information in the section “Safety Regulations” at the beginning of this manual. 2) Correctly mount the scanner according to the information in par. 2.2.1 and position it at the correct reading distance as shown in par. 4.4. 3) Make electrical connections to your DX8200A scanner by: a) Connecting the DX8200A Master scanner to the C-BOX 100 by means of one of the CAB-601X cables provided as accessory (see par. 1.5). b) Correctly terminating the DX8200A Master reader according to the information given under “Local Lonworks Network” in par. 2.3.2 and par. 2.5.5. c) Completing the system wiring adding as many slave scanners as required by your system layout (refer to par. 2.5.5). d) Correctly providing bus return to the last DX8200A Slave reader of the network according to the information given under “Local Lonworks Network” in par. 2.3.2 and par. 2.5.5. 4) Install and run the Genius™ configuration program from the CD-ROM provided. Configure the Local Lonworks Network using one of the procedures given below: a) Configure the entire network through the Master as described in par. 3.2.2; b) Configure the Master as described in par. 3.2.2 and locally define each slave scanner address as described in par. 3.2.3. c) Define each scanner, master and slaves (with their addresses), by using the scanner keypad according to the information given in par. 2.6.1. 5) Configure the Master scanner through the Genius™ program. The main steps are: •

Select the codes to be read

•

Set-up the communication parameters

•

When PackTrack™ is required, perform PackTrack™ calibration, see par. 4.2.1.

•

Define data formatting parameters

6) Configure each Slave scanner through the Master scanner using Genius™. The main steps are: •

Select the codes to be read

•

When PackTrack™ is required, perform PackTrack™ calibration, see par. 4.2.1.

Fine tuning of the scanner position for barcode reading can be accomplished by performing a test through the SPY configuration tool in Genius™. NOTE

7)

Send the configuration to the Master.

xiii

Page 16

8) Optionally, perform the ASR Network Configuration procedure for system backup purposes (see par. 5.2.1). 9) Exit the configuration program and run your application. The installation is now complete.

xiv