Browse
(440) 299-7778
Menu
(440) 299-7778
One-year parts and labor warranty30-day money-back guaranteeEnglishEspañolContact

The text of a manual · part 14 of 15

DX8200A Reference Manual: TECHNICAL FEATURES

Pages 89 to 92 of 97, from DX8200A Reference Manual

The original document is the PDF (6.2 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.

Filed in the catalog under the Datalogic DX8200

Page 89

TECHNICAL FEATURES

7

7 TECHNICAL FEATURES ELECTRICAL FEATURES VAC models

Supply voltage Power consumption Common Communication Interfaces

VDC models

110 to 230 Vac 20 to 30 Vdc 30 VA typical 30 W typical 35 W Max. (including startup current) Main

Baud Rate

RS232 RS485 full-duplex RS485 half-duplex 20 mA C.L. (INT-30 with C-BOX 100 only) Auxiliary

RS232

1200 to 115200 19200 1200 to 115200

Other

Lonworks 1,25 Mb/s Model–Dependent Communication Ethernet 100 Mb/s Interfaces Profibus up to 12 Mb/s DeviceNet up to 500 Kb/s Inputs (optocoupled NPN or PNP) Ext. Trigger 1, 3 aux. digital inputs Outputs (optocoupled) 3 software programmable digital outputs OPTICAL FEATURES Light receiver Avalanche photodiode Wavelength 630 to 680 nm Safety class Class 2 - EN60825-1; Class II - CDRH Light source Up to 4 semiconductor laser diodes Laser control Security system to turn laser off in case of motor slow down READING FEATURES Scan rate Maximum resolution Max. reading distance Max. reading width Max. depth of field USER INTERFACE LCD Display Keypad LED indicators

≤ 1000 scans/s (500 per leg)

(see reading diagrams in par. 4.4)

2 lines by 20 characters LCD 3 keys Power On (green) TX Data (green) Phase On (yellow) Network (red) Encoder (yellow)

73

Page 90

DX8200A

7 SOFTWARE FEATURES Readable Codes

Code selection Headers and Terminators Operating modes Configuration modes Parameter storage ENVIRONMENTAL FEATURES Operating temperature Storage temperature Humidity Ambient light immunity Vibration resistance: EN 60068-2-6 2 hours on each axis

Interleaved 2/5 Code 39 Standard Codabar Code 128 EAN 128 Code 93 (standard and full ASCII) EAN/UPC (including Add-on 2 and Add-on 5) Up to 10 codes during one reading phase Up to 128-byte headers and 128-byte terminators On Line, Serial On Line, Automatic, Test, PackTrack™, Continuous Genius™ utility program Non-volatile internal FLASH 0° to +50 °C (+32° to +122 °F) -20° to +70 °C (-4° to +158 °F) 90% non condensing 20000 lux Frequency range from 5 to 150 Hz; Constant displacement 3 mm pk-pk from 5 to 9 Hz; Constant acceleration 0.5 g from 9 to 150 Hz

Shock resistance: IEC 68-2-27 test EA 3 shocks on each axis Protection class PHYSICAL FEATURES Mechanical dimensions Weight *

74

30 g; 11 ms VAC models

VDC models

IP54*

IP64*

470 x 300 x 141 mm (18.50 x 11.81 x 5.55 in) about 11 kg (24 lbs. 3 oz)

sealed connectors required; use Harting RJ Industrial® Push Pull Ethernet connector for Ethernet models.

Page 91

SCANNER CONVERSION

A

A

SCANNER VAC TO VDC CONVERSION (OPTIONAL)

It is possible to convert the DX8200A VAC model into a VDC model by inserting an internal jumper.

The following operation should be performed by qualified personnel only. CAUTION

Before unscrewing the panel of the DX8200A, make sure the power supply cable is disconnected to avoid shock or harm to the operator. WARNING

Follow the procedure below: 1. Unscrew the Display and Keypad panel screws to open the scanner. 2. Carefully remove the panel as shown in Figure 66.

Figure 66 - Opening the DX8200A

75

Page 92

DX8200A

A 3. Disconnect the internal Vdc power connector, referring to Figure 67.

Figure 67 - Disconnecting the Vdc internal power supply connector

4. Connect the external Vdc jumper onto the power connector, referring to Figure 68.

Figure 68 - Connecting the power supply jumper for external Vdc operation

5. Replace and tighten the Display and Keypad panel screws to close the scanner.

You must supply Vdc power externally through the 17-pin connector.

76