For the Datalogic CM900

Page 1

OPERATOR’S MANUAL

CM900 AutoID Interface Module

Manual Revision 5, 3-01 Publication #17-1122

Page 2

Escort Memory Systems Warranty Escort Memory Systems warrants that all products of its own manufacture conform to Escort Memory Systems specifications and are free from defects in material and workmanship when used under normal operating conditions and within the service conditions for which they were furnished. The obligation of Escort Memory Systems hereunder shall expire one (1) year after delivery, unless otherwise specified, and is limited to repairing, or at its option, replacing without charge, any such product which in Escort Memory Systems’s sole opinion proves to be defective within the scope of this Warranty. In the event Escort Memory Systems is not able to repair or replace defective products or components within a reasonable time after receipt thereof, Buyers shall be credited for their value at the original purchase price. Escort Memory Systems must be notified in writing of the defect or nonconformity within the warranty period and the affected product returned to Escort Memory Systems factory or to an authorized service center within thirty (30) days after discovery of such defect or nonconformity. Shipment shall not be made without prior authorization by Escort Memory Systems. This is Escort Memory Systems’s sole warranty with respect to the products delivered hereunder. No statement, representation, agreement or understanding oral or written, made by an agent, distributor, representative, or employee of Escort Memory Systems which is not contained in this warranty, will be binding upon Escort Memory Systems, unless made in writing and executed by an authorized Escort Memory Systems employee. Escort Memory Systems makes no other warranty of any kind whatsoever, expressed or implied, and all implied warranties of merchantability and fitness for a particular use which exceed the aforestated obligation are hereby disclaimed by Escort Memory Systems and excluded from this agreement. Under no circumstances shall Escort Memory Systems be liable to Buyer, in contract or in tort, for any special, indirect, incidental, or consequential damages, expenses, losses or delay however caused. Equipment or parts which have been subject to abuse, misuse, accident, alteration, neglect, unauthorized repair or installation are not covered by warranty. Escort Memory Systems shall make the final determination as to the existence and cause of any alleged defect. No liability is assumed for expendable items such as lamps and fuses. No warranty is made with respect to custom equipment or products produced to Buyer’s specifications except as specifically stated in writing by Escort Memory Systems in the contract for such custom equipment. This warranty is the only warranty made by Escort Memory Systems with respect to the goods delivered hereunder, and may be modified or amended only by a written instrument signed by a duly authorized officer of Escort Memory Systems and accepted by the Buyer. Extended warranties of up to four years are available for purchase for most EMS products. Contact EMS or your distributor for more information. This document contains proprietary information which is protected by copyright. All rights are reserved. The information in this manual has been carefully checked and is believed to be accurate; however, no responsibility is assumed for possible inaccuracies or omissions. Specifications are subject to change without notice. EMS®, Escort Memory Systems® and the EMS® logo are registered trademarks of Escort Memory Systems, a Datalogic Group Company. Other brand and product names mentioned are trademarks or registered trademarks of their respective holders. Escort Memory Systems, Inc. A Datalogic Group Company 170 Technology Circle Scotts Valley, CA 95066 Telephone (831) 438-7000 FAX (831) 438-5768 www.ems-rfid.com ii

Copyright © 2001, Escort Memory Systems Inc. CM900 AutoID Interface Module

Page 3

TABLE OF CONTENTS 1

GETTING STARTED 1.1 1.2 1.3

2

3

5

5.3 5.4 5.5 5.6

12

Standard Program & Custom Loadable . . . . . . . . . . . . . 12 C Language Development Package . . . . . . . . . . . . . . 12

CM900 STANDARD PROGRAM 5.1 5.2

5

22-Position Connector . . . . . . . . . . . . . . . . . . . . . . 5 Indicators . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 Power Requirements . . . . . . . . . . . . . . . . . . . . . . 8 RS232 Serial Interface . . . . . . . . . . . . . . . . . . . . . 9 RS422 Serial Interface . . . . . . . . . . . . . . . . . . . . . 10 RFID Port Interface . . . . . . . . . . . . . . . . . . . . . . . 11

TECHNICAL OVERVIEW 4.1 4.2

3

Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 Mounting the CM900 . . . . . . . . . . . . . . . . . . . . . . 4

POWER AND ELECTRICAL INTERFACE 3.1 3.2 3.3 3.4 3.5 3.6

4

Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 Unpacking and Inspection . . . . . . . . . . . . . . . . . . . . 2 Organization of This Manual . . . . . . . . . . . . . . . . . . 2

MECHANICAL SPECIFICATIONS 2.1 2.2

1

13

Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . 13 Configuring the PLC . . . . . . . . . . . . . . . . . . . . . . . 14 CM900 Personality . . . . . . . . . . . . . . . . . . . . . . . 14 Modifying the GCNFA120.SYS File . . . . . . . . . . . . . . . 14 Traffic-Copping . . . . . . . . . . . . . . . . . . . . . . . . . 14 Communication Overview . . . . . . . . . . . . . . . . . . . . 15 Port Addressing . . . . . . . . . . . . . . . . . . . . . . . . . 16 Command Set Overview . . . . . . . . . . . . . . . . . . . . 17 Command Descriptions . . . . . . . . . . . . . . . . . . . . . 18 Command 0 (00 Hex): Idle . . . . . . . . . . . . . . . . . . . 18 Command 1 (01 Hex): RF Port Noncontiguous Read . . . . . . 19 Command 2 (02 Hex): RF Port Noncontiguous Write . . . . . . 20 Command 3 (03 Hex): RF Port Configure Noncontiguous R/W Addresses . . . . . . . . . . . . . . . . . 21 Command 4 (04 Hex): RF Port Fill Tag . . . . . . . . . . . . . 23 Command 5 (05 Hex): RF Port Block Read . . . . . . . . . . . 24

Copyright © 2001, Escort Memory Systems Inc. CM900 AutoID Interface Module iii

Page 4

5.7

Command 6 (06 Hex): RF Port Block Write . . . . . . . . . . . 25 Command 10 (10 Hex): Serial Port Configure . . . . . . . . . . 26 Command 11 (11 Hex): Serial Port Block Read . . . . . . . . . 28 Command 12 (12 Hex): Serial Port Block Write . . . . . . . . . 29 Command 13 (13 Hex): Clear Serial Port . . . . . . . . . . . . 30 Command 20 (20 Hex): Posted Block Write . . . . . . . . . . . 31 Command 21 (21 Hex): Posted Block Read . . . . . . . . . . . 33 Command 22 (22 Hex): Read Posted Read Data Buffer . . . . 34 Command 23 (23 Hex): Posted Commands Status Byte . . . . 35 Command 24 (24 Hex): Cancel Posted Operations . . . . . . . 37 Error Codes . . . . . . . . . . . . . . . . . . . . . . . . . . . 38

A

APPENDIX: NOTICE OF EMISSIONS

40

B

APPENDIX: SPECIFICATIONS

41

C

APPENDIX: MODELS & ACCESSORIES

43

D

APPENDIX: ASCII CHART

45 iv

Copyright © 2001, Escort Memory Systems Inc. CM900 AutoID Interface Module

Page 5

1 GETTING STARTED 1.1 Introduction Escort Memory Systems’ CM900 AutoID Interface Module is an advanced peripheral for the Modicon 984 Compact PLC rack. The CM900 expands a host PLC’s data collection and dissemination capabilities by providing an RFID antenna port and serial communication facilities. A standard application program is included with each unit. The standard program requires that a custom loadable, Escort Memory Systems’ SP1004 software program, be loaded on the host PLC. For custom programming, the SP1011 C Language Development Package with custom libraries, is available. The Franklin Compiler required for CM900 Software development must be order separately, EMS part number 881001. The CM900’s fully-buffered, bi-directional serial communications port is configurable to support RS232 and RS422 communications formats. It can be set to communicate with a wide variety of devices, via selectable baud rate, parity, and number of data bits and stop bits. A dedicated RS232 port is also provided for programming and debugging. The RFID antenna port is compatible with Escort Memory Systems’s industry® leading EMS Read/Write RFID components. The communications connection between the CM900 and antenna is via two twisted pair wires (four wires) with a maximum cable length of 1,200 meters (4,000 ft). The CM900 also features 32K bytes of nonvolatile EEPROM program storage as well as 32K bytes of system RAM. Seven status LEDs mounted on the front of the CM900 greatly assist program debugging and maintenance.

Copyright © 2001, Escort Memory Systems Inc. CM900 AutoID Interface Module

1

Page 6

1.2 Unpacking and Inspection Unpack the CM900 and retain the original shipping carton and packing material in case any item has to be returned to Escort Memory Systems. Inspect each item carefully for evidence of damage. If any item appears to be damaged, notify Escort Memory Systems immediately. Check that all of the following items are present: CM900 AutoID Module Operator’s Manual Standard Program Diskette

1.3 Organization of This Manual This manual presents in Chapters 2, 3, and 4 the essential information required for installing, connecting and powering the CM900. The following chapters explain the configuration and operation of the CM900.

2

Copyright © 2001, Escort Memory Systems Inc. CM900 AutoID Interface Module

Page 7

2 MECHANICAL SPECIFICATIONS 2.1 Dimensions Figures 1 and 2 show the overall dimensions of the CM900 module. The enclosure is identical to that of other 984 Compact components.

All dimensions are in inches mm

Figure 1, CM900 Front and Rear Views

Copyright © 2001, Escort Memory Systems Inc. CM900 AutoID Interface Module

3

Page 8

All dimensions are in inches mm

Figure 2, CM900 Side View

2.2 Mounting the CM900 WARNING! Turn power to the PLC rack and CM900 OFF before installing or removing the CM900. The CM900 can be inserted into the Modicon 984 Compact Rack at any location. Hook the top of the CM900 enclosure to the hook provided on the rack and press in the unit completely to ensure good contact with the backplane. Secure the unit by tightening the slotted screw at the bottom of the enclosure.

4

Copyright © 2001, Escort Memory Systems Inc. CM900 AutoID Interface Module

Page 9

3 POWER AND ELECTRICAL INTERFACE 3.1 22-Position Connector Connections between the CM900 and the front-end external power supply, serial ports, and EMS remote RFID antenna are via a 22-position connector for terminal strips located on the front of the unit as shown in Figure 3. Two 11-position mating terminal strips are supplied with the unit. Table 1 shows the pinouts for the 22-position connector.

Figure 3, CM900 Connectors

Copyright © 2001, Escort Memory Systems Inc. CM900 AutoID Interface Module

5

Page 10

Table 1 - RFID Port/Power Connector Pinouts

6

Pin

Function

Pin

Function

1

+24 VDC

12

+24 VDC

2

+24 VDC

13

+24 VDC

3

COM1 RS422 RX+

14

COM2 RS232 RX (Programming Port )

4

COM1 RS422 RX-

15

COM2 RS232 TX (Programming Port )

5

COM1 RS422 TX+

16

COM2 Signal Ground (Programming Port )

6

COM1 RS422 TX-

17

Antenna, Pin 1

7

COM1 RS232 RX

18

Antenna, Pin 2

8

COM1 RS232 TX

19

Antenna, Pin 3

9

COM1 RS232 GND

20

Antenna, Pin 4

10

No Connection

21

Ground

11

Ground

22

Ground

Copyright © 2001, Escort Memory Systems Inc. CM900 AutoID Interface Module