A four-page spec sheet from EMS, a Datalogic Group company, for the CM900 Automatic ID Module, which connects bar code scanners, RFID antennas and other serial devices directly to the Modicon Compact PLC backplane and Micro I/O expansion bus. It gives electrical, communication, memory, mechanical and environmental specifications, terminal pinouts, and the accessories and software for custom programs. It helps an integrator check power, ports and PLC compatibility before fitting a CM900.
- Device
- Automatic ID module that plugs into the Modicon Compact backplane and Micro I/O expansion bus, adding bar code, RFID and serial ASCII data handling p. 1
- Ports
- Two serial ports (COM1 RS232 or RS422; COM2 RS232 programming port) and an RFID antenna port p. 1, 3
- Power
- Backplane 5VDC ±5%, 250mA max.; external 24VDC ±15%, 250mA without antenna, 750mA with antenna p. 2
- Memory
- 32KB battery-backed static RAM; 32KB EEPROM for the application program (2KB used by system) p. 2
- RFID antenna port
- For EMS HS/HL-Series antennas; RS422-like interface on two twisted pairs, cable up to 4000 feet; 3000 bytes per second to the tag p. 1
- Serial settings
- 300 to 19200 baud; none, odd or even parity p. 2
- PLC data transfer
- Uses 6 registers (96 inputs and 96 outputs); a PLC function block transfers 1-127 registers between PLC and CM900 p. 2
- Software
- Ships with a standard program (Fill Tag, Block and Non-Contiguous Read/Writes); C programmable for custom applications p. 1
- Required program
- SP1004 is required to run the standard program p. 4
- Devices supported
- EMS passive read only and active read/write RFID, EMS bar code scanners, any RS232 or RS422 serial device p. 1, 2
- Connectors
- Two 11-position plug-in terminal strips, mating connectors furnished p. 2, 4
- Size and weight
- 4.43 x 5.59 x 1.57in. (113 x 142 x 40mm); 0.62lbs. (0.304kg) p. 2
- Humidity
- 95% non-condensing p. 2
- Accessory part numbers
- SP1011-LIB, 88-1001, CBL-1182, CBL-1183, CBL-1184, CBL-1185, 46-1285, 46-1286 (software libraries, C compiler, demonstration and programming cables, connector assemblies) p. 4
What this sheet walks you through
- Connecting serial, bar code and RFID devices to a Modicon Compact PLC p. 1
- RFID port, power and serial port terminal pinouts p. 3
Good to know
- The front end needs an external 24VDC supply; only the backplane side is powered by the PLC. p. 2
- The software manual and libraries diskette does not include the compiler, tools or compiler manual. p. 4
Questions this sheet answers
Which PLC does the CM900 module work with?
It plugs directly into the Modicon Compact backplane and Micro I/O expansion bus. p. 1
What power does the Datalogic CM900 need?
5VDC from the PLC backplane plus an external 24VDC ±15% supply, drawing up to 750mA with an antenna. p. 2
How long can the CM900 antenna cable be?
Up to 4000 feet, on two twisted pairs, to an EMS HS/HL-Series antenna. p. 1
The file
Size and text
Every page · 4
Read it here
Each page as it is printed, and its words beside it, so a phone can search and copy them.
Page1of 4
Open in the PDF
The text of page 1, from the PDF itself
CM900 Automatic ID Module Features
- Direct Connection to the Modicon Compact Backplane and Micro I/O Expansion Bus
- Two Serial Ports for Interface to Bar Code Scanners or other Serial Devices
- Flexible Standard Program to Eliminate Most Custom Programming Needs
- C Programmable for Custom/Unique Applications
- 32KB of BatteryBacked RAM
- 32KB EEPROM
Applications
- Material Handling
- Sortation Systems
- Work-in-Progress Monitoring
- Quality Control
Use With
- EMS Passive Read Only
- EMS Active Read/Write
- RS232 and RS422 Serial Devices
a Datalogic Group Company, is the field-proven leader in the development and application of Radio Frequency Identification (RFID) Tags/Labels/PCBs, Antennas, Controllers and network interface modules for tough industrial environments. With over a dozen years of RFID successes in the automotive, electronics, material handling and food processing industries, EMS has built a global reputation in providing customers with complete supply chain solutions – from production to retail EMS has the complete solution!
EMS,
The CM900 Automatic ID module, developed together with Modicon through the ModConnect Partners program, allows all serial devices as well as bar code and Read/Write Radio Frequency Identification (RFID) products, to be connected directly to the Modicon Compact series backplane and Micro I/O expansion bus. The CM900 expands the role of the Compact PLC by adding ASCII data handling capability. In addition to the backplane interface, the CM900 has two serial ports and an RFID Antenna port. The CM900 Module comes to the end-user already loaded with a standard program that allows the user to access all the CM900 functionality while remaining within the PLC programming environment.
functions: Fill Tag, Block Read/Writes and NonContiguous Read/Writes. Custom programs can be easily developed by using the development package. Technical Description The CM900 achieves high data exchange rates by utilizing an advanced high speed microprocessor. The master microprocessor executes the application program while communicating with the PLC backplane. The system has 32KB of battery-backed RAM for storage of runtime variables, ATA RANSFER pointers, tables, and in-process ATE OF data transactions. The application YTES program is stored ER ECOND on an ultra-reliable 32KB EEPROM. This combination of high speed microprocessor and large memory capacity allows the CM900 to internally handle serial and RFID transactions and simply pass the requested registers of data to the host PLC processor.
DTR 3,000/B P S
The RFID Antenna port is compatible with all EMS’ HS/HL-Series Antennas. The electrical interface to the Antenna is similar to RS422 and uses two twisted pairs with a maximum cable length of 4000 feet. This interface has an effective data transfer rate to the RFID Tag of 3000 bytes per second.
The RFID command set of the standard program allows the user to perform the following Your Complete Supply Chain RFID Provider – Call: 831/438-7000
Fax: 831/438-5768Web: www.ems-rfid.com189
Page2of 4
Open in the PDF
The text of page 2, from the PDF itself
CM900 Automatic ID Module Electrical
Backplane - Supplied by PLC Supply Voltage 5VDC ±5% Maximum Current 250mA Front End - External Supply Required Supply Voltage 24VDC ±15% Maximum Current 250mA (without Antenna) 750mA (with Antenna) Maximum Ripple 2.0% of DC Voltage
Communication
Modicon Compact PLC, Direct – Connect to Backplane and Micro I/O Expansion Bus
Ports
COM1 COM2 RFID Port Name Maximum Cable Length
RS232/RS422 RS232 ANT 4000ft. (1200m)
Internal Memory
Master Microprocessor Application Program Storage
32KB Battery-Backed Static RAM 32KB EEPROM, 2KB Used by System
Interface to Serial Devices
Serial Port Names Compatibility
COM1, COM2 (Programming/Debug) EMS Bar Code Scanners Any Third-party External Serial Device 300, 600, 1200, 2400, 4800, 9600, 19200 None, Odd, Even 7 or 8 1 or 2
Baud Rate Parity Data Bits Stop Bits Interface to Modicon Backplane
Traffic-Cop Compatibility SP1004 Loadable
Mechanical Specifications
Dimensions (W x H x D) Weight Connectors Backplane
Environment
Operating Temperature Storage Temperature Humidity Shock Resistance Vibration Resistance Altitude ESD Immunity Magnetic Immunity Noise Emissions
Your Complete Supply Chain RFID Provider – Call: 831/438-7000
190
CM900 for 6-Register Transfer Requiring 96 Inputs and 96 Outputs PLC Function Block Allows Transfer of 1-127 Registers of Data Between PLC and CM900 4.43 x 5.59 x 1.57in. (113 x 142 x 40mm) 0.62lbs. (0.304kg) (2) 11-Position Plug-in Terminal Strips (Mating Connector Furnished) Direct Plug-in to Modicon Compact PLC Housings 32° to 120°F (0° to 49°C) -40° to 185°F (-40° to 85°C) 95% Non-Condensing 30G for 11ms 30G at 3-500Hz for 23 Minutes Per Plane, 1 Octave/Minute in All Three Planes 15,000ft. (4,540m), Per MIL-STD-810, Method 500.2, Low Pressure 8kV to All Surfaces, Per IEC 801-2, Level Tests Per IEC 801-3, Level 3 FCC Part 15, Subpart B, Class A; CDC Class B
Fax: 831/438-5768
Web: www.ems-rfid.com
Page3of 4
Open in the PDF
The text of page 3, from the PDF itself
CM900 Automatic ID Module Mechanical Dimensions
inches mm
Serial Port Connectors Electrical Connections
RFID Port/Power Pinouts Pin Function 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22
Your Complete Supply Chain RFID Provider – Call: 831/438-7000
Fax: 831/438-5768
+24 VDC +24 VDC COM 1 RS422 RX+ COM 1 RS422 RXCOM 1 RS422 TX+ COM 1 RS422 TXCOM 1 RS232 RX COM 1 RS232 TX COM 1 RS232 GND No Connection Ground +24 VDC +24 VDC COM2 RS232 RX (Programming Port) COM2 RS232 TX (Programming Port) COM2 Signal Ground (Programming Port) Antenna, Pin 1 Antenna, Pin 2 Antenna, Pin 3 Antenna, Pin 4 Ground Ground
Web: www.ems-rfid.com
191
Page4of 4
Open in the PDF
The text of page 4, from the PDF itself
CM900 Automatic ID Module Available Models Model CM900
Accessories Model SP1011-LIB
88-1001 SP1004CBL-1182CBL-1183
CBL-1184 CBL-1185 46-1285 46-1286
Description Automatic ID Module for Compact and Micro-Series PLCs. Mating Connectors Included. Requires SP1004 to Run Standard Program.
Description Software Manual and Libraries for Use in Developing Custom Application Programs for the CM900 Auto ID Module. Diskette Includes Libraries and Standard Program Source Code. Does Not Include Compiler, Tools or Compiler Manual. Franklin C Compiler for CM900 Software Development. Software Loadable Program for most Models of the Modicon 984 CPU (Excluding 984-A,-B,-X) and most Models of the Modicon Compact Series, (Excluding Compact CPU - 120 Models). Required to Run Standard Program. Demonstration Cable Set. Includes Two 10′ Long RS232 Connection Cables to the Main (DB-25S) and Programming Ports (DE-9P), 10′ Long Connection Cable for HS500/HS501 Antenna, and 24VDC Wall Mount Power Supply. Terminal Strip Connectors Included. Demonstration Cable Set. Includes Two 10′ Long RS232 Connection Cables to the Main (DB-25S) and Programming Ports (DE-9P), 10′ Long Connection Cable for HS / HL500A / HS / HL501A Antenna, and 24VDC Wall Mount Power Supply. Terminal Strip Connectors Included. Cable Assembly, PC AT-to-CM900 Programming Cable, 10′ long, DE-9P to Terminal Strip. Includes Power Supply. Cable Assembly, PC XT-to-CM900 Programming Cable, DB-25S to Terminal Strip. Includes Power Supply. 10′ Long. Connector Assembly, CM900, for Connection to Pins 12-22 Connector Assembly, CM900, for Connection to Pins 1-11
Your Complete Supply Chain RFID Provider – Call: 831/438-7000
192Fax: 831/438-5768Web: www.ems-rfid.com