Browse
(440) 299-7778
Menu
(440) 299-7778
One-year parts and labor warranty30-day money-back guaranteeEnglishEspañolContact
Page 1 of Datalogic CM11 Escort Spec Sheet

Spec sheet · Datalogic

Datalogic CM11 Escort Spec Sheet

Spec sheet4 pagesPDF 170 KB

All 4 pages are below, each with its text.

Download the PDF170 KB

Covers · 1 model

The models it covers

From the sheet · read page by page

Key facts from this sheet

Each line names its page in the PDF.

Spec sheet from EMS, a Datalogic Group company, for the CM11 and CM12 DeviceNet interface modules. The CM11 links RS232 and other serial devices such as RFID controllers and bar code readers to a DeviceNet network, and the CM12 links an HS500-Series RFID antenna. It lists features, electrical, serial, mechanical and environment specifications, and accessories.

Device
CM11: DeviceNet interface module that gives RS232 devices such as RFID controllers and bar code readers a presence on the DeviceNet CAN Bus p. 1
Serial port
CM11: RS232, RS422, RS485, Mux32; up to 32 serial devices on the Mux32 RS485 bus p. 1, 2
Power
CM11: 24VDC ±15%; 90mA max.@24VDC with no connected devices p. 2
Serial settings
CM11: 300, 600, 1200, 2400, 4800, 9600, 19200 baud; odd, even or no parity p. 2
Input and output
One industrial-level input and one industrial-level output, 10-30VDC p. 2, 3
Size and enclosure
4.92 x 3.15 x 2.21in. (125 x 80 x 56mm), W x H x D; aluminum p. 2, 3
Sensor input
CM11: one general purpose opto-isolated input for a presence sensor, proximity sensor or relay; an optically isolated output for trigger signals or as a switch p. 1
Cable length
CM11: 50ft. (15m) RS232; 1000ft. (300m) RS422, RS485, Mux32 p. 2
Data handling
CM11: standard program is a buffered pass-through of serial data to and from the CAN Bus p. 1
Environment
95% non-condensing humidity; NEMA 4 (IP66) p. 2, 3
CM12 ports
CM12: one HS500-Series read/write antenna port and one RS232 port for ASCII data and firmware downloads p. 1
CM12 power
CM12: 24VDC@250mA max; 120mA max.@24VDC with no connected devices; from DeviceNet or an external source p. 1, 3
CM12 serial
CM12: RS232, 9600 baud p. 3
Accessories
Franklin C-Compiler for CM11 software development; demonstration kit with CBL-1222, CBL-1224, CBL-1226, 46-1377; mating connectors p. 4

What this sheet walks you through

  • How the CM11 passes serial data over DeviceNet p. 1
  • Using the CM12 to connect an RFID antenna to a PLC p. 1
  • CM11 and CM12 specifications p. 2, 3
  • Available models and accessories p. 4

Good to know

  • CM11 serial cables are limited to 50ft. (15m) for RS232 and 1000ft. (300m) for RS422, RS485 and Mux32. p. 2
  • No more than 32 serial devices on the CM11 Mux32 RS485 bus. p. 1

Questions this sheet answers

What does the Datalogic CM11 do?

It is a DeviceNet interface module that lets RS232 and other serial devices, such as RFID controllers and bar code readers, talk directly on a DeviceNet network. p. 1

What power does the CM11 need?

24VDC ±15%, drawing 90mA max. at 24VDC with no devices connected. p. 2

How many serial devices can connect to one CM11?

As many as 32 serial devices on the Mux32 RS485 bus. p. 1

What is the difference between the CM11 and the CM12?

The CM11 links serial devices to DeviceNet. The CM12 links an HS500-Series RFID antenna to a PLC over DeviceNet and also has one RS232 port. p. 1

The file

Size and text

Pages4
PDF170 KB
TextText from the PDF itself.

Every page · 4

Read it here

Each page as it is printed, and its words beside it, so a phone can search and copy them.

Page 1 of Datalogic CM11 Escort Spec Sheet

The text of page 1, from the PDF itself

CM11 / CM12 DeviceNet Interface Modules Features

  • One Full Duplex RS232, RS485(Mux32), or RS422 Serial Port
  • One Programming/ Configuration Port
  • One Sensor Port with One Optically Isolated Output
  • External or CAN Bus Power
  • LED Indicators for Network and Serial Communications Status
  • 32KB EEPROM Program Memory and 32KB Static RAM Data Memory
  • Hardware Watchdog Timer

Applications

  • Material Handling
  • Sortation Systems
  • Work-in-Progress Monitoring
  • Quality Control

Use With

EMS Passive Read/Write EMS Passive Read Only EMS Active Read/Write Any RS232 Serial Device HL-Series

a Datalogic Group Company, is the field-proven leader in the development and application of Radio Frequency Identification (RFID) Tags/Labels/PCBs, Antennas, Controllers and network interface modules for tough industrial environments. With over a dozen years of RFID successes in the automotive, electronics, material handling and food processing industries, EMS has built a global reputation in providing customers with complete supply chain solutions – from production to retail EMS has the complete solution!

EMS,

The CM11 can be used to give a DeviceNet presence to Auto ID equipment such as RFID Controllers, bar code readers/scanners, sensors and switches. The CM11 interfaced to a DeviceNet program allows all of EMS’ RS232 devices (as well as other RS232 devices) to have a direct presence on the DeviceNet CAN Bus. As many as 32 serial devices may be attached via the Mux32 RS485 bus. Technical Description To an existing DeviceNet system, the CM11 DeviceNet module is a buffered, full duplex, serial channel. The standard program provides a buffered pass-through of serial data. The converter buffers incoming serial data, assembles packets and transmits them over the CAN Bus. Similarly, incoming packets from the CAN Bus are buffered and then transmitted out the serial lines.

Your Complete Supply Chain RFID Provider – Call: 831/438-7000

One general purpose, opto-isolated, input line is provided for connection of a presence sensor, proximity sensor or relay. The input is passed to the CPU and acted on according to the configuration parameters. The input may be passed back within the CM11 or sent out to the network to be EVICE ET processed by the PLC. An opticallyRESENCE isolated output FOR can be used to send trigger signals UTO or operates as a switch.

D PNA ID PRODUCTS

EMS’ CM12 is an external device that allows an EMS RFID Antenna to interface with the PLC through ODVA’s Device-Net network. The CM12 has one HS500-Series Read/Write Antenna port in addition to one RS232 serial port, which can be used for ASCII data stream transmission and to download updated firmware. An I/O input and output are also provided for sensor control. A standard mini-connector is used for DeviceNet network connections. The simplified command sets are defined so Read/Write Tag commands can be easily constructed in PLC and communicated through DeviceNet. Power can either be supplied from the DeviceNet network or from an external power source.

Fax: 831/438-5768Web: www.ems-rfid.com153

Page 2 of Datalogic CM11 Escort Spec Sheet

The text of page 2, from the PDF itself

CM11 / CM12 DeviceNet Interface Modules CM11 DeviceNet Interface Module Electrical

Supply Voltage Current Consumption

24VDC ±15% 90mA max.@24VDC No Connected Devices

Serial Interface

Serial Port Type Baud Rate Parity Data Bits Stop Bits Max. Cable Length

RS232, RS422, RS485, Mux32 300, 600, 1200, 2400, 4800, 9600, 19200 Odd, Even, None 7 or 8 1 50ft. (15m) RS232 1000ft. (300m) RS422, RS485, Mux32

Mechanical Specifications

Dimensions (W x H x D) Enclosure Cables

4.92 x 3.15 x 2.21in. (125 x 80 x 56mm) Aluminum User Supplied

Environment

Operating Temperature Storage Temperature Humidity Protection Class

32° to 120°F (0° to 49°C) -40° to 185°F (-40° to 85°C) 95% Non-Condensing NEMA 4 (IP66)

Input/Output

Input Output

One Industrial-Level Input, 10-30VDC One Industrial-Level Output, 10-30VDC

Mechanical Dimensions

inches mm

Your Complete Supply Chain RFID Provider – Call: 831/438-7000

154Fax: 831/438-5768Web: www.ems-rfid.com

Page 3 of Datalogic CM11 Escort Spec Sheet

The text of page 3, from the PDF itself

CM11 / CM12 DeviceNet Interface Modules CM12 DeviceNet Interface Module Electrical

Supply Voltage Maximum Ripple Current Consumption

24VDC@250mA max 2% of Supply Voltage 120mA max.@24VDC with No Connected Devices 2.35mA max.@24VDC with HS500 Antenna

Serial Interface

Serial Port Type Baud Rate Parity Data Bits Stop Bits Max. Cable Length

RS232 9600 Odd, Even, None 8 1 50ft. (15m)

Mechanical Specifications

Dimensions (W x H x D) Enclosure Cables

4.92 x 3.15 x 2.21in. (125 x 80 x 56mm) Aluminum User Supplied

Environment

Operating Temperature Storage Temperature Humidity Protection Class

32° to 120°F (0° to 49°C) -40° to 185°F (-40° to 85°C) 95% Non-Condensing NEMA 4 (IP66)

Input/Output

Input Output

One Industrial-Level Input, 10-30VDC One Industrial-Level Output, 10-30VDC

Mechanical Dimensions

inches mm

Your Complete Supply Chain RFID Provider – Call: 831/438-7000

Fax: 831/438-5768Web: www.ems-rfid.com155

Page 4 of Datalogic CM11 Escort Spec Sheet

The text of page 4, from the PDF itself

CM11 / CM12 DeviceNet Interface Modules Available Models Model

Description

CM11 CM12

DeviceNet Interface Module, HMS-Series DeviceNet Interface Module, HS500-Series

Accessories Model

Description

88-1001 CBL-1222 CBL-1224 CBL-1226 46-1377 00-1062 46-1089 46-1357 46-1393

Franklin C-Compiler for CM11 software development Programming/Debug Cable, CM11 to PC Unterminated Cable, CM11, 3 ft. length CM11 to RS427-10 Demonstration Cable, 18″ length Terminal Plug for AB 1747SDN DeviceNet module Demonstration Kit, includes: CBL-1222, CBL-1224, CBL-1226, 46-1377 Mating Connector to RS232 port (right angle) Mating Connector to sensor port Mating Connector to DeviceNet

Your Complete Supply Chain RFID Provider – Call: 831/438-7000

156Fax: 831/438-5768Web: www.ems-rfid.com