Page 12

C-BOX 100

2

2

INSTALLATION

2.1

PACKAGE CONTENTS

Verify that the C-BOX 100 and all the parts supplied with the equipment are present and intact when opening the packaging; the list of parts includes: 1) 2)

C-BOX 100 Installation manual

2

1

Figure 1 - C-BOX 100 Package Contents

2

Page 13

INSTALLATION

2.2

2

OPENING THE DEVICE

To install the C-BOX 100 or during normal maintenance, it is necessary to open it by unscrewing the four cover screws:

The C-BOX 100 must be disconnected from the power supply during this operation. CAUTION

Figure 2 - Opening the C-BOX 100

It is possible to perform the following operations: •

Proceed with the cable connections (see paragraph 2.4.2).

•

Mount the C-BOX 100 to a wall or panel.

3

Page 14

C-BOX 100

2

2.3

MECHANICAL INSTALLATION

The diagram below gives the overall dimensions of the C-BOX 100 and may be used for its installation.

Figure 3 - Overall Dimensions

4

Page 15

INSTALLATION

2

C-BOX 100 can be installed to operate in different positions. The two screw holes inside the housing of the C-BOX 100 are for mechanical fixture (Figure 4). To mount the C-BOX 100: 1)

Open the C-BOX 100 by unscrewing the 4 cover screws. If necessary, using the two mounting holes inside the device as a pattern, mark the panel with an appropriate object and then drill two holes in the panel.

2)

Align the C-BOX 100 and insert two screws and screw them into the panel until tight (see Figure 4).

Figure 4 - Mounting C-BOX 100

5

Page 16

C-BOX 100

2

2.4

ELECTRICAL CONNECTIONS AND SETUP

The following figure shows the typical layout. The dotted line in the figure refers to an optional hardware configuration.

PC Scanner Auxiliary Interface SCANNER EXT TRIG

TX DATA

POWER ON

G OOD READ

System Cables Figure 5 – System Layout

A PC can be quickly connected to the C-BOX 100 (and consequently to the scanner auxiliary interface) through the internal 9-pin connector. This allows monitoring of the data transmitted by the scanner or configuration through the WinHost utility (see the scanner Installation Manual for more details). The scanner auxiliary interface signals are also available on the internal spring clamp connectors. After making system cabling and switch settings (see sub-paragraphs under 2.4), connect the scanner to the 25-pin connector on the left side of the C-BOX 100 housing. Switch ON the C-BOX 100 power switch (see Figure 6). The correct polarity of the power connection is signaled by the green LED, while the red LED turns on in case of wrong polarity.

NOTE

Power is supplied to the connected scanner (25-pin connector only) through an electronic circuit which: limits the slew rate of the power supplied to the scanner and, therefore, the inrush current at the input capacitors; provides short circuit protection and over current protection (automatic retry).

After system functioning has been verified, close the C-BOX 100 using the 4 cover screws making sure the rubber seal is fitted correctly between the parts of the housing.

6

Page 17

INSTALLATION

2.4.1

2

Power Supply

Power is supplied to the C-BOX 100 through the pins provided on the spring clamp connector. The power switch (see Figure 6) switches the power supply ON or OFF for both the C-BOX 100 and the connected scanner.

S1

ON

OFF

Figure 6 - Power Switch ON/OFF Positions

USER INTERFACE

C-BOX 100 1

VS V+ (10 - 30 Vdc)

2

GND GND

Figure 7 - Power Supply Connections

Pin 1 is also electrically connected to pins 3 and 5, just as pin 2 is electrically connected to pins 4 and 6. This is useful for external trigger/inputs connections. NOTE

The power supply must be between 10 and 30 Vdc only.

7

Page 18

C-BOX 100

2

2.4.2

System Wiring

The connection and wiring procedure for C-BOX 100 is described as follows: 1)

Open the C-BOX 100 as described in paragraph 2.2.

2)

Verify that the C-BOX 100 power switch is off (see Figure 6).

3)

Unscrew the compression connectors and pass all the system cables through them into the C-BOX 100 housing.

4)

To connect the power and input/output signals: •

Prepare the individual wires of the system cables by stripping the insulation back approximately 1 cm.

•

Using a device such as a screwdriver, push down on the lever directly next to the clamp (see Figure 8).

•

Insert the wire into the clamp and release the lever.

The wire will now be held in the spring clamp.

Figure 8 - System Cable Connections

The wiring used can be solid or stranded but must meet the following specifications. All positions:

24 - 16 AWG

0.2 - 1.5 mm²

The C-BOX 100 spring clamp connector pinouts are indicated in the following table. Refer to the scanner Installation Manual for details.

8

Page 19

INSTALLATION

Pin 1, 3, 5 2, 4, 6 7, 8 *9, 13 20, 40 35 37

21 22 23 24 25 26 27 28 29 30 31 32 33 34 36 38 *39

*11, 15 *12, 16 17 18 *10, 14, 19

2

Name VS GND EARTH GROUND RS485 CABLE SHIELD RESERVED TX AUX RX AUX DS2100 DS4300 DS1100 DS6XXX MATRIX-2XXX DS2400 DS4600/A DS2200 (MATRIX-1XXX) OUT1+ OUT1+ OUT1+ OUT1+ OUT1+ (NC) OUT REF OUT1IO REF OUT1OUT1- (NC) OUT2+ OUT2+ OUT2+ OUT2+ OUT2+ (NC) OUT REF OUT2IO REF OUT2OUT2- (NC) NC RESERVED NC OUT 3A OUT3+ NC RESERVED IN1OUT 3B OUT3EXT TRIG+ EXT TRIG+ EXT TRIG+ EXT TRIG A EXT TRIG A EXT TRIGEXT TRIGEXT TRIGEXT TRIG B EXT TRIG B NC IN1+ NC IN 2A IN 2A (NC) NC IN1IO REF IN 2B IN 2B(NC) NC IN2+ NC IN 3A NC NC IN2NC IN 4A NC RESERVED RESERVED RESERVED IN 3A NC RESERVED RESERVED RESERVED IN 4A NC RTSA GND NC IN 3B/IN 4B NC CTSA SGND AUX NC GND GND SGND SGND SGND GND GND DS2100 DS2400 DS4300 DS1100 DS2200 DS4600/A DS6XXX MATRIX-2XXX (MATRIX-1XXX) RS232 RS485FD RS485HD 20mA CL (**) RTX485HD TX232 TX485+ RTX485+ CLOUT+ *** RTX485+ RTS232 TX485RTX485CLOUTRTX485RX232 RX485+ CLIN+ *** RESERVED (NC) CTS232 RX485CLINRESERVED (NC) SGND MAIN SGND MAIN SGND MAIN SGND MAIN SGND MAIN

*

The signals on pins 9, 10, 11 and 12 are repeated on pins 13, 14, 15 and 16 to facilitate network connections (i.e. Multiplexer connections using the RS485 half-duplex Interface). In this way the network bus can enter and exit the C-Box 100 from different spring clamps but be physically connected together; ** 20 mA C.L. interface is not available for MATRIX-2XXX; *** For DS4XXX scanners, the CLOUT+ and CLIN+ signals are available only when using a passive 20 mA C.L. interface (see relevant manuals for details);

Pin 7 or 8 should be connected to the earth ground. NOTE

9

Page 20

C-BOX 100

2

NOTE

2.4.3

Grounding varies according to the scanner connected to the C-BOX 100: for DS2XXX scanners, pins 10, 14 and 19 (SGND MAIN) are internally connected to pin 39 (SGND); for DS4XXX scanners, pins 10, 14 and 19 (SGND MAIN) are internally connected to pin 39 (SGND); for DS6XXX scanners, the SGND MAIN pins are isolated (GND MAIN_ISO). for MATRIX-2XXX readers, the SGND MAIN pins are isolated (GND MAIN_ISO); for MATRIX-1XXX readers, SGND MAIN is internally connected to the GND through a filtering circuit.

Chassis Grounding Jumper Settings

The scanner chassis grounding method can be selected by positioning a jumper (see Figure 9). In this way the scanner chassis can be connected to earth ground (only if pins 7 or 8 are connected to a good earth ground) or to the power supply ground signal. The scanner chassis can also be left floating but, in this case, the jumper must be removed.

to EARTH GROUND (default)

to GND floating

Figure 9 – Chassis Grounding

The C-BOX 100 is now installed which completes the electrical connections for your scanning system.

10

Page 21

INSTALLATION

2.4.4

2

Scanner Selection

The following figure indicates the correct switch position for each type of scanner. DS1100 DS2200 A B Other Devices Figure 10 - Scanner Selection

The switch S3 must be set to A only when a DS1100 or a DS2200 scanner (10-30 V version) is connected. For all the other scanners the switch S3 must be set to B.

2.4.5

RS485 Bus Termination

ON OFF S2

Figure 11 - Termination Resistance Switch

The switch S2 enables or disables the insertion of the bus termination resistor for RS485 Half Duplex Multidrop applications.

CAUTION

In Multiplexer applications the termination resistor must be enabled ONLY on the last device of the chain, the farthest away from the Multiplexer (assuming the Multiplexer is the first device of the chain). On all the other devices this resistor MUST NOT be enabled (S2 = OFF). Normally it is not necessary to enable the terminator resistor (S2 always OFF); it is suggested only in applications where the communication speed or the bus length are critical parameters.

11

Page 22

C-BOX 100

2

2.4.6

OM4000 Jumper Settings

J2

J1

Figure 12 - OM4000 Jumpers

These jumpers allow connection to the EXT TRIG signals on separate spring clamp terminals for applications which use the OM4000 Oscillating Mirror in Trigger Mode. They are used together and have the following significance: when a jumper is in the J1 position (see Figure above) pin 40 is connected to pin 27 (EXT TRIG+); a jumper in J2 position connects pin 20 to pin 28 (EXT TRIG-). If the jumpers are removed pin 20 and pin 40 are disconnected.

12

Page 23

INSTALLATION

2.5

2

9-PIN SCANNER AUXILIARY SERIAL INTERFACE

The scanner auxiliary serial interface available on the internal 9-pin connector can be used either for configuration through WinHost or for data monitoring. The details of the connector pins are indicated in the following table:

Figure 13 - 9-pin Male Connector

9-pin connector pinout Pin 1 2 3 4 5 6 9

Name

7 8

CTSA RTSA

Auxiliary Handshake RS232 Auxiliary Handshake RS232 DS4300 - DS4600/A

7 8

SGND AUX GND

7 8

N.C. N.C.

7 8

GND N.C.

7 8

GND Not used

Auxiliary Signal Ground Ground DS1100 - DS2200 N.C. N.C. MATRIX-2XXX/1XXX Ground N.C. DS6XXX Ground Not used

RXA TXA SGND

Function N.C. Auxiliary RS232 Auxiliary RS232 N.C. Signal Ground N.C. N.C. DS2100 - DS2400

13

Page 24

C-BOX 100

3

3

TECHNICAL FEATURES

ELECTRICAL FEATURES Power

Supply voltage Power consumption Max current consumption (short circuit protection on 25-pin connector)

10 to 30 Vdc* 0.5 W + scanner power consumption (see related manual) 2 to 2.5 A

USER INTERFACE LED indicators

Power on LED (green) Power polarity error LED (red)

PHYSICAL FEATURES Mechanical dimensions Weight

167 x 115 x 40 mm (6.57 x 4.53 x 1.57 in.) about 320 g. (11.29 oz.)

ENVIRONMENTAL FEATURES Operating temperature

-10° to 50 °C (+14° to 122 °F)

Storage temperature

-20° to 70 °C (-4° to 158 °F)

Humidity max. Vibration resistance

90% non condensing IEC 68-2-6 test FC 1.5 mm; 10 to 55 Hz; 2 hours on each axis

Shock resistance

IEC 68-2-27 test EA 30G; 11 ms; 3 shocks on each axis

Protection Class

*

IP64 (when correctly connected to the scanner)

for further details about minimum/maximum supply voltage refer to the manual of the connected scanner, since the minimum supply voltage required may be >10.

The features given are typical at a 25 °C ambient temperature (if not otherwise indicated). NOTE

14

Page 25

DATALOGIC S.p.A., Via Candini, 2 40012 - Lippo di Calderara Bologna - Italy dichiara che declares that the déclare que le bescheinigt, daß das Gerät declare que el C-BOX 100, passive connection box

01 e tutti i suoi modelli and all its models et tous ses modèles und seine modelle y todos sus modelos sono conformi alle Direttive del Consiglio Europeo sottoelencate: are in conformity with the requirements of the European Council Directives listed below: sont conformes aux spécifications des Directives de l'Union Européenne ci-dessous: der nachstehend angeführten Direktiven des Europäischen Rats: cumple con los requisitos de las Directivas del Consejo Europeo, según la lista siguiente: 89/336/EEC EMC Directive e and et und y

92/31/EEC, 93/68/EEC emendamenti successivi further amendments ses successifs amendements späteren Abänderungen succesivas enmiendas

Basate sulle legislazioni degli Stati membri in relazione alla compatibilità elettromagnetica ed alla sicurezza dei prodotti. On the approximation of the laws of Member States relating to electromagnetic compatibility and product safety. Basée sur la législation des Etates membres relative à la compatibilité électromagnétique et à la sécurité des produits. Über die Annäherung der Gesetze der Mitgliedsstaaten in bezug auf elektromagnetische Verträglichkeit und Produktsicherheit entsprechen. Basado en la aproximación de las leyes de los Países Miembros respecto a la compatibilidad electromagnética y las Medidas de seguridad relativas al producto.

Questa dichiarazione è basata sulla conformità dei prodotti alle norme seguenti: This declaration is based upon compliance of the products to the following standards: Cette déclaration repose sur la conformité des produits aux normes suivantes: Diese Erklärung basiert darauf, daß das Produkt den folgenden Normen entspricht: Esta declaración se basa en el cumplimiento de los productos con las siguientes normas:

EN 55022, August 1994:

LIMITS AND METHODS OF MEASUREMENTS OF RADIO DISTURBANCE CHARACTERISTICS OF INFORMATION TECHNOLOGY EQUIPMENT (ITE)

EN 50082-2, March 1995:

ELECTROMAGNETIC COMPATIBILITY. GENERIC IMMUNITY STANDARD. PART 2: INDUSTRIAL ENVIRONMENT

Lippo di Calderara, 07/03/2001

Ruggero Cacioppo

Quality Assurance Supervisor