Spec sheet · Datalogic
Datalogic C-Box 100, C-Box 150 and C-Box 200 Spec Sheet
Spec sheet2 pagesPDF 315 KB
Both pages are below, each with its text.
Covers · 3 models
The models it covers
From the sheet · read page by page
Key facts from this sheet
Each line names its page in the PDF.
A two-page Datalogic data sheet for the C-Box line of industrial connection boxes for fixed and hand-held bar code readers. It covers the C-Box 100, 150, 200, 300, 310, 400 and 410, explains wiring, configuration storage and fieldbus links, and gives a specification table and dimension drawings.
- What it is
- Industrial connection box that simplifies cabling of Datalogic bar code readers p. 1
- Compatible readers
- 1000, 2000, 4000 and 6000 series scanners, Matrix, Gryphon and Dragon hand-helds p. 1
- Scanner connector
- External standard D-Shell 25 pin p. 1
- Service port
- Internal D-Shell 9 pin for the scanner's auxiliary interface, on all models p. 1
- Wiring
- Internal spring-clamp terminal block and 5 external cable glands p. 1
- Power supply
- 10 to 30 Vdc p. 2
- Power control
- Internal switch and LED for power supply status p. 1
- Configuration storage
- C-Box 200, 3x0 and 4x0: GET, STORE and SEND the reader's configuration in non volatile memory p. 1
- Fieldbus models
- C-Box 300/310: Profibus DP on a D-Shell 9 pin; C-Box 400/410: DeviceNet on an M12 connector p. 1
- Display and keypad
- C-Box 310/410: external display and keypad p. 1
- Setup software
- Winhost, for the connected readers and the fieldbus interfaces p. 1
- Humidity
- 90% non condensing p. 2
What this sheet walks you through
- Wiring a reader through the spring clamps and cable glands p. 1
- Saving and restoring a reader's configuration for quick replacement p. 1
- Connecting a reader directly to Profibus DP or DeviceNet p. 1
- Setting up readers and fieldbus interfaces with Winhost p. 1
- Dimension drawings of the C-Box 100/150/200, 300/310 and 400/410 p. 2
Good to know
- The sheet states an IP64 protection class. p. 2
Questions this sheet answers
Which scanners work with the Datalogic C-Box 100?
The C-Box line is made for the 1000, 2000, 4000 and 6000 series scanners, Matrix, and the Gryphon and Dragon hand-held readers. p. 1
What voltage does the Datalogic C-Box need?
10 to 30 Vdc. p. 2
Can a C-Box store a scanner's configuration?
Yes, the C-Box 200, 3x0 and 4x0 can get, store and send the configuration of the connected reader in non volatile memory. p. 1
How does a scanner plug into the C-Box?
Through an external standard D-Shell 25 pin connector; an internal D-Shell 9 pin gives access to the auxiliary service interface. p. 1
Which C-Box connects to Profibus or DeviceNet?
The C-Box 300/310 has built-in Profibus DP and the C-Box 400/410 has built-in DeviceNet. p. 1
The file
Size and text
Every page · 2
Read it here
Each page as it is printed, and its words beside it, so a phone can search and copy them.
Page1of 2
Open in the PDF
The text of page 1, from the PDF itself
C-Box Line Industrial Connection Box Product Line
Unattended Scanning Systems
General Description The Datalogic C-Box Line is the ideal solution to simplify and speed up cabling operations during the installation of barcode readers. It can be connected to the most important fieldbuses in the market. The C-Box line has been designed to be used with the scanners of the 1000, 2000, 4000 and 6000 series and Matrix™, as well as the Gryphon and Dragon hand-held readers. The C-Box Line is equipped with an internal terminal block made of practical spring clamps and 5 external cable glands for easy cabling operations. Connection to the scanner is made through an external standard D-Shell 25 pin connector. All models have an internal standard D-Shell 9 pin connector to access the auxiliary service interface of the scanner. The ease of use is enhanced thanks to an internal switch and Led, which control the power supply status, and an external display and keypad (C-Box 310/410). System downtime is reduced and scanner replacement is quick because it is possible to GET, STORE and SEND the configuration of the connected product directly in the non volatile internal memory of the C-Box 200, 3x0 and 4x0. The C-Box 300/310 have built-in Profibus DP connectivity, while the C-BOX 400/410 offer built-in connectivity to Devicenet, allowing the reader to be directly connected to the fieldbus with no need for wiring a proprietary intermediate bus. Connection to the fieldbus is fast, with an external standard D-Shell 9 pin connector (Profibus DP) or an external industrial M12 connector (DeviceNet). Both the connected products and the fieldbus interfaces can be set through the use of the Winhost™ setup program.
www.datalogic.com
Features > Standardization: unique solution for the entire Datalogic scanner range
> Fast installation and maintenance :
- Ease and flexibility in the cabling operation
- Fast access to the auxiliary interface of the product
- Power supply switch and LED > Possibility to GET/STORE and SEND the configuration of the connected products > Connectivity to Profibus DP and DeviceNet > Display versions > Winhost™ configuration SW > Cost Effective
Applications > Manufacturing > Shop Floor > Warehousing
Page2of 2
Open in the PDF
The text of page 2, from the PDF itself
Unattended Scanning Systems Industrial Connection
C-Box Line Box Product Line Specifications C-BOX 100 ELECTRICAL CHARACTERISTICS POWER SUPPLY 10 to 30 Vdc POWER CONSUMPTION USER INTERFACE LEDS DISPLAY & KEYPAD PHYSICAL CHARACTERISTICS DIMENSIONS WEIGHT
C-BOX 150C-BOX 20010 to 30 Vdc Max 2.5 W10 to 30 Vdc Max 1.4 W10 to 30 Vdc Max 3.5 W
10 to 30 Vdc Max 3 W Max 4.5 W
Yes NoYes No, 3 keysYes No, 3 keys
Yes Yes No, 2 int. keys Yes, 3 keys
Yes Yes No, 3 int. keys Yes, 3 keys
See drawing Approx. 320g (11.29 oz)
See drawing Approx. 410g (14.48 oz)
See drawing Approx. 340 g (12 oz)
See drawing See drawing Approx. 440 g Approx. 500 g Approx. 470 g Approx. 530 g (15.51 oz) (17.63 oz) (16.50 oz) (18.70 oz)
SOFTWARE FEATURES CONFIGURATION STORAGE
Non volatile Non volatile internal memory internal memory WINHOST™
CONFIGURATION CONNECTIVITY COMMUNICATION PROTOCOL INTERFACE TYPE DATA TRANSFER RATE EXCHANGE MEMORY FOR I/O DATA ADDRESS SETTING HANDSHAKING
Multidrop MUX32 RS485 (optocoupled) Up to 56 Kbit/s
HW Switches
ENVIRONMENTAL FEATURES OPERATING TEMPERATURE STORAGE TEMPERATURE HUMIDITY VIBRATION RESISTANCE SHOCK RESISTANCE PROTECTION CLASS SCANNERS SUPPORTED
C-BOX 300C-BOX 310C-BOX 400C-BOX 410
Non volatile internal memory Non volatile internal memory WINHOST™ Profibus DP Up to 12 Mbit/s Up to 32 bytes HW Switches, WINHOST™ Message fragmentation and flow control
WINHOST™ Devicenet CAN 125, 250, 500 Kbit/s Up to 32 bytes HW Switches, WINHOST™ Message fragmentation and flow control
-10 to 50° C (14 to 122° F) -20 to 70° C (-4 to 158° F) 90% non condensing IEC 68-2 Test FC 1.5 mm; 10 to 55 Hz; 2 hours on each axis IEC 68-2-27 Test EA 30 G; 11 ms; 3 shocks on each axis IP64 The entire range
The entire range*
DS2100A, DS2400A, DS2100A, DS2400A, DS4600A DS2100A, DS2400A, DS4600A DS4600A, Matrix™ Matrix™ Matrix™
- The 10 to 30 Vdc versions are used for the DS1100 and DS2200 scanners. Matrix™ not supported
Dimensionsmm inchC-Box 100/150/200C-Box 300/310C-Box 400/410