Page 1 of DAP PC9000 Spec Sheet

Spec sheet · DAP

DAP PC9000 Spec Sheet

Spec sheet3 pagesPDF 42 KB

All 3 pages are below, each with its text.

Download the PDF42 KB

Covers · 1 model

The models it covers

From the sheet · read page by page

Key facts from this sheet

Each line names its page in the PDF.

A settings sheet for the DAP Technologies Microflex PC9000 hand-held, written after bench testing by Electronic Data Solutions with the DataPlus DOS software. It lists the recommended direct-connect and modem communication settings for sending an application to the hand-held and for transferring data to the PC.

Device
DAP Technologies Microflex PC9000 hand-held p. 1, 2
Handshaking
DTR/DSR only for hardware handshaking; no DCD (Data Carrier Detect) connection p. 1
Display
21 columns x 16 lines p. 2
Serial port
Com 1 (15 pin connector) p. 2
Drive
RAM Drive (A:) p. 2
Keyboard
All keyboard combinations used by DataPlus are available p. 1
Software tested
DataPlus DOS software; the PC9000 generally ran with standard settings p. 1
Direct, send application
9,600 baud, Xon/Xoff on both the PC9000 and the PC p. 2
Direct, transfer data
38,400 baud, DTR/DSR on both the PC9000 and the PC p. 2
Modem
100% Hayes compatible; tested with a Hayes Accura 144+Fax144 p. 3
Modem, PC side
115,200 baud or lower, the highest the PC can use with its modem p. 3

What this sheet walks you through

  • Direct-connect settings for sending an application to the hand-held p. 2
  • Settings for transferring data to the PC in Host Mode p. 2
  • Modem connection settings p. 3

Good to know

  • For a direct connection, the settings on the PC9000 (DataPlus) and the PC (Application Generator) must match exactly. p. 2
  • The PC9000 has no DCD (Data Carrier Detect) connection. p. 1
  • The modem should be 100% Hayes compatible. p. 3

Questions this sheet answers

What baud rate does the PC9000 use to transfer data to a PC?

Over a direct connection the sheet lists 38,400 baud with DTR/DSR flow control on both sides. p. 2

Does the DAP PC9000 have a DCD line?

No. It uses DTR/DSR only for hardware handshaking and has no DCD connection. p. 1

Which modem works with the PC9000?

A 100% Hayes compatible modem; a Hayes Accura 144+Fax144 was used in testing. p. 3

What is the PC9000 display size?

The sheet lists 21 columns x 16 lines. p. 2

The file

Size and text

Pages3
PDF42 KB
TextText from the PDF itself.

Every page · 3

Read it here

Each page as it is printed, and its words beside it, so a phone can search and copy them.

Page 1 of DAP PC9000 Spec Sheet

The text of page 1, from the PDF itself

DAP Technologies Microflex® PC9000 Headquarters:

DAP TECHNOLOGIES 955 Place Dufour Ville de Vanier, Quebec Canada G1M 3B2 (418) 681-9394

Electronic Data Solutions performed bench testing of the PC9000 with the DataPlus DOS software. The parameter settings on the following pages are recommended for the PC9000 to efficiently run the DataPlus product. In general, the PC9000 ran with the standard settings. These comments were noted:

All keyboard combinations used by DataPlus are available.

The best communication settings, as tested, are listed on the following pages. The PC9000 utilizes DTR/DSR only for communication hardware handshaking. It does not have a DCD (Data Carrier Detect) connection.

® Microflex is a registered trademark of DAP Technologies.

Page 2 of DAP PC9000 Spec Sheet

The text of page 2, from the PDF itself

Communication Settings The PC9000 was tested with these settings: Display Size: Drive: Com Port tested:

21 columns x 16 lines RAM Drive (A:) Com 1 (15 pin Connector)

DIRECT Connect Both settings on the PC9000 (DataPlus) and the PC (Application Generator) must match exactly. (These are the fastest, most reliable settings as tested.) Sending an Application to the Hand-Held: Description Baud Rate Data Bits Parity Stop Bits Flow

PC9000 (DataPlus) 9,600 N/A N/A N/A Xon/Xoff

PC (Host) 9,600 8 None 1 Xon/Xoff

Transferring Data to the PC (Host Mode): Description Baud Rate Data Bits Parity Stop Bits Flow

MODEM Connect 2

PC9000 (DataPlus) 38,400 N/A N/A N/A DTR/DSR

PC (Host) 38,400 8 None 1 DTR/DSR

Page 3 of DAP PC9000 Spec Sheet

The text of page 3, from the PDF itself

The modem should be a 100% Hayes compatible modem. In testing, a Hayes Accura 144+Fax144 modem was used. (These are the fastest, most reliable settings as tested.) Sending an Application to the Hand-Held: Description

PC9000 (DataPlus)Baud Rate9,600

Data Bits Parity Stop Bits Flow DCD (data carrier

N/A N/A N/A Xon/Xoff No

PC (Host) 115,200 or lower. The highest the PC can communicate with its modem 8 None 1 RTS/CTS N/A

detect) Transferring Data to the PC (Host Mode): Description

PC9000 (DataPlus)Baud Rate38,400

Data Bits Parity Stop Bits Flow DCD (data carrier

N/A N/A N/A Xon/Xoff No

PC (Host) 115,200 or lower. The highest the PC can communicate with its modem 8 None 1 RTS/CTS N/A

detect)

3