Page 17

4910

INSTALLATION AND OPERATION

XTAL

1

J36

P1

6

1

FR JB4

J32

RST JB2 L1 15

LL

JB1

ON

RST NOR

AUTO BLACK

VIDEO OUT

FLD

OFF

JB5

CR60

6 J35 1

Q21

JB6

NOR

J37

JB3

SIDE A

Figure 12. Jumper Locations, Video/Sync Board

LINE PHASE (ADJUST FROM REAR PANEL)

J23

PRE

JB60

8

V.D.

1

J21

P2

8

LINE PHASE

R112 J25

1

1

JB80

TP1

TP61 75 OHM SYNC TERMINATION SELECT

BOARD GROUND

POWER INPUT COMMON

Figure 13. Jumper Location, Genlock/P.S. Board

8. Repeat steps 2 through 7. Make a slightly different adjustment to the LEVEL control in step 4 while maintaining a good picture on the picture monitor. After all conditions in these steps have been met, proceed to step 9. 9. Test the camera under actual operating conditions, if desired, and after verifying proper operation return it to service.

6X-924(E)

9.0 SIDE PANEL ADJUSTMENTS Four adjustments and three switches appear under a panel on the left side of the Camera. They are described in table 4. Cameras are shipped with these controls set either for operation under typical conditions or as requested by the user. When the ELECT IRIS switch is set to ON, the eight-position shutter speed selection switch immediately to its right is deactivated. ELECT IRIS is an optional feature used with manual iris lenses that does not appear on all versions of the camera.

17

Page 18

INSTALLATION AND OPERATION

4910 NON-INTERLACE

INTERLACE FIELD 1

FRAME SCANNING

FIELD 2

1

2

3

4

5

6

INTEGRATION TIME

INTEGRATION TIME VS. VIDEO OUT

FIELD 1 1

3

3

5

5

FIELD 1

FIELD 1

FIELD 2

FIELD 2

(ON-TYPICAL SHUTTER)

VERTICAL DRIVE

VD

VD 1/60(1/50)SEC

VIDEO OUT

INTEGRATION TIME (SHUTTER OFF)

FIELD 2

1

1/60(1/50)SEC 1

2

VIDEO OUT

1

2

VIDEO OUT

SENSITIVITY

NORMAL

ONE-HALF NORMAL

VERTICAL RESOLUTION - TV LINES

485(575)

242(287)

NOTE: WHEN ASYNCHRONOUSLY RESETTING WITH THE SHUTTER ON IN FRAME MODE, VIDEO OUTPUT OCCURS IN 1/60(1/50) SECOND.

Figure 14. Frame Integration Mode

NON-INTERLACE

INTERLACE FIELD 1 1 2 3 4 5 6

FIELD SCANNING

INTEGRATION TIME VS. VIDEO OUT (ON-TYPICAL SHUTTER)

INTEGRATION TIME (SHUTTER OFF)

INTEGRATION TIME

FIELD 2

FIELD 1 1 2 3 4 5 6

2 3 4 5

FIELD 1

FIELD 1 FIELD 2

FIELD 2

VERTICAL DRIVE VIDEO OUT

FIELD 2 1 2 3 4 5 6

VD

VD 1/60(1/50)SEC 1

VIDEO OUT

1/60(1/50)SEC 1

2

2

VIDEO OUT

SENSITIVITY

NORMAL

NORMAL

VERTICAL RESOLUTION - TV LINES

350(450)

242(287)

Figure 15. Field Integration Mode

18

6X-924(E)

Page 19

4910

INSTALLATION AND OPERATION

10.0 INTERNAL ADJUSTMENTS

CAUTION

ELECTROSTATIC SENSITIVE DEVICES DO NOT OPEN OR HANDLE EXCEPT AT A STATIC-FREE WORKSTATION

Six repositionable jumpers are accessible when the case is removed from the Camera. Table 5 lists these jumpers and describes their functions. Their locations on the video/sync and genlock/powersupply boards are shown in figures 12 and 13. Do not make any adjustments to components on the circuit boards when the case has been removed to reposition a jumper. Performing internal setup adjustments requires test instruments and detailed step-by-step procedures. Such procedures appear in section V of the Installation, Operation, and Maintenance Manual (6X-925). Perform internal setup adjustments only when the step-by-step procedures in that manual are being followed. Be aware that adjusting anything electrical or mechanical without the proper procedure may void the warranty of a new Camera. Refer to the last page of this manual for the warranty.

11.0 REAR PANEL LINE-LOCK PHASE ADJUSTMENT Multiple Cameras operating from 12 (or the optional 24) V ac input power can have their vertical intervals locked together by using the power line frequency as a reference. The internal crystal/line-lock (XTAL/LL) jumper on the video/sync board of all Cameras must be positioned to LL to use this feature. Several situations can cause Cameras not to have their vertical intervals occurring at the same time when all are locked to the ac input power at the Camera rear panel. 1. Power input at the Camera rear panel may be 180 degrees out-of-phase relative to the Camera chosen as the reference. This is because the two leads at the power input connector are reversed in relation to the reference Camera.

6X-924(E)

2. Some Cameras may be operating off different phases of the main power line. This could position vertical intervals out-of-phase by, for example, 180 degrees or even 120 or 240 degrees relative to the power line. 3. Other phase shifts in power distribution equipment may be significant enough to cause problems in some applications. Two actions can be performed at each Camera to put its vertical interval in phase with the vertical interval chosen as reference. (1) The rear panel PHASE control can be adjusted to provide up to 180 degrees of control. (2) If more than 180 degrees is required, the two power input leads can be reversed for a 180-degree phase shift. Then adjust the rear panel PHASE control for the final amount required. The adjustment is generally done by observing video at the switcher where all the video cables converge. Use a dual-channel oscilloscope. Video from one Camera is selected as the reference. Then the input power leads and PHASE controls on all other Cameras are changed as necessary to bring their vertical intervals into alignment with the reference Camera. In summary, then: 1. Adjust the rear panel PHASE control for up to 180 degrees of control 2. Switch the two power leads at the rear panel when more than 180 degrees of control is required. Then make a final adjustment with the PHASE control.

12.0 ELECTRONIC-IRIS/ MANUAL-IRIS-LENS SETUP When turned ON, the optional electronic iris board provides automatic control of Camera sensitivity to scene lighting through a range of nearly eight f/stops. It does this by electronically shuttering the sensor in the Camera through a continuous range from 1/15,000 second (scene very bright) to 1/60 (1/50) second (scene not well lighted). The manual-iris lens must be set to bring the light handling capability of the electronic iris within range of the sensor. For indoor use where scene lighting typically is not extremely bright and does not vary more than

19

Page 20

INSTALLATION AND OPERATION seven f/stops, the iris on the manual lens can usually be set wide open. If fluorescent lights illuminate the scene, use line lock mode to prevent interference with the electronic-iris circuits. For viewing a scene where the light is extremely bright and can vary more than seven f/stops (such as an outdoor scene), the iris on the manual lens must be stopped down somewhat. This is to bring the light reaching the sensor into a range that the electronic iris can handle. Proceed as follows to make this setting: 1. Verify that the Camera is viewing the scene of interest and that no further positioning adjustments are required. 2. Wait for the brightest time of day on the scene being viewed by the Camera. 3. Open the manual iris fully while observing the indicator lamp on the rear panel (fig. 3). As the lens is opened this lamp should go out at some point, indicating that the electronic iris has run out of range (and thus is at 1/15,000 s). 4. Slowly close the lens iris until the rear panel indicator just comes on again. This is the proper setting for the manual iris lens. If blooming is observed on the picture monitor while using the electronic iris feature, it is likely that scene lighting has become too bright for the electronic iris circuit.

13.0 OPERATING MODES The four basic scanning modes are: Frame mode, interlaced Frame mode, non-interlaced Field mode, interlaced Field mode, non-interlaced The Camera can be operated with non-interlaced scanning only when externally applied horizontal and vertical drive are used to establish a noninterlaced condition. Timings appear first as RS-170 followed by CCIR timings in parenthesis. Note in the two illustrations that a shutter interval is shown together with the integration time for

20

4910 fields 1 and 2. The long line is the integration time without shuttering. The boxed portion at the end of the long integration line is a representative integration period for shutter mode. The key point is that shuttering occurs near the end of a vertical interval. 13.1 Frame Mode, Interlaced Refer to figure 14. In the interlaced frame mode, the sensor integrates each field for 1/30 (1/25) second, spanning two vertical intervals. Note that field-2 begins integrating midway through the integration of field-1. Field-1 is comprised of odd lines, field-2 of even lines. In this mode pixels are not paired to form lines. Thus the maximum vertical resolution of about 485 (575) tv lines is available. Since this mode integrates each field for 1/30 (1/25) second it is more prone to problems with relative movement between the Camera and scene. 13.2 Frame Mode, Non-interlaced Refer to figure 14. Each field is scanned for 1/60 (1/50) second. Each field is integrated on the sensor during its own interval. Only the odd lines are used. Vertical resolution is about 242 (287) tv lines. This is about one-half that available with the frame interlaced mode. This mode has about one-half the sensitivity of the other three modes. Reduced sensitivity results due to the combination of integration occurring for 1/60 (1/50) second and pixels not being combine. In the other three sensor operating modes, normal specified sensitivity is maintained due either to 1/30 second integration or to two lines of pixels being combined to form a single line. 13.3 Field Mode, Interlaced Refer to figure 15. In the interlaced field mode, the sensor integrates for 1/60 (1/50) second and combines two rows of pixels to form the lines. Note that to form field-1, pixels in lines one and two are combined. Then to form field-2 pixels in lines two and three are combined. Because two lines of pixels are being combined to form each line, this mode provides the normal specified sensitivity, but it has less vertical resolution than the interlaced frame mode.

6X-924(E)

Page 21

4910

INSTALLATION AND OPERATION

This mode has less lag than the interlaced frame mode because of its 1/60 (1/50) second rate. 13.4 Field Mode, Non-interlaced Refer to figure 15. In the non-interlaced field mode, the Camera operates at a 1/60 (1/50) second rate. The same two rows of pixels are combined to produce each line for both fields. This results in the lower vertical resolution of 242 (287) tv lines. Because two lines of pixels are combined to form each line, though, normal specified sensitivity is obtained.

CAUTION SENSITIVE ELECTRONIC DEVICES DO NOT SHIP OR STORE NEAR STRONG ELECTROSTATIC, ELECTROMAGNETIC, MAGNETIC OR RADIOACTIVE FIELDS

14.0 PREPARATION FOR SHIPMENT AND STORAGE For storage periods exceeding about one month, seal the unit in a vapor-proof bag containing a fresh desiccant pack. Maintain the Camera storage environment within a range of -30 to 70 °C (-22 to 158 °F). For shipment, package with enough foam padding or other packing material to prevent damage

6X-924(E)

that can occur during shipping. The original shipping carton is a good container if it has not been damaged or subjected to excessive moisture. For shipping to the factory by Common Carrier, use 3912 Calle Fortunada, San Diego, CA 92123-1827 as the address. Please contact the Customer Service Department for a Return Authorization (RA) number before sending any shipments to the factory.

Change 1

21

Page 22

INSTALLATION AND OPERATION

4910

WARRANTY Cohu, Inc., Electronics Division, warrants equipment manufactured to be free from defects of material and workmanship. Any part or parts will be repaired or replaced when proven by Cohu examination to have been defective within two years from date of shipment to the original purchaser for standard CCD cameras and one year from date of shipment to the original purchaser for intensified CCD cameras and all other Cohu manufactured products. All warranty repairs will be performed at the factory or as otherwise authorized by Cohu in writing. Transportation charges to Cohu shall be prepaid by purchaser. This warranty does not extend to Cohu equipment subjected to misuse, accident, neglect, or improper application, nor repaired or altered by other than Cohu or those authorized by Cohu in writing. Television image pickup tubes, image intensifiers, lenses, and products manufactured by companies other than Cohu are warranted by the original manufacturer. This warranty is in lieu of all other warranties expressed or implied. Cohu shall not be liable for collateral or consequential damages. A Return Authorization (RA) number must be obtained from Cohu prior to returning any item for warranty repairs or replacement.

COHU

January 29, 1999 Rev. 1. 10-1-99

Cohu, Inc. Electronics Division

22

Change 1

6X-924(E)