The text of a manual · part 1 of 1
Catalyst 2900 Series XL Installation Guide, Appendix A: Technical Specifications, pages 1 to 6
Pages 1 to 6 of 6
The original document is the PDF (79 KB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Cisco Catalyst 2900
Page 1
APPENDIX
A
Technical Specifications Table A-1, Table A-2, and Table A-3 list the technical specifications for the Catalyst 2900 series XL switches. For WS-C2912MF-XL, WS-C2924M-XL-A, and WS-C2924M-XL-EN switches, refer to the Catalyst 2900 Series XL Modules Installation Guide and the Catalyst 2900 Series XL ATM Modules Installation Guide for additional specifications. Table A-4 lists the agency approvals for EMI and safety.
Technical Specifications A-1
Page 2
Table A-1
Technical Specifications for the Catalyst 2912 XL and Catalyst 2912MF XL Switches Catalyst 2912 XL
Catalyst 2912MF XL
32 to 113°F (0 to 45°C)
32 to 113°F (0 to 45°C)
Storage temperature
–4 to 149°F (–10 to 65°C)
–4 to 149°F (–10 to 65°C)
Operating humidity
10 to 85% (noncondensing)
10 to 85% (noncondensing)
Operating altitude
Up to 10000 ft (3000 m)
Up to 10000 ft (3000 m)
Storage altitude
Up to 15000 ft (4570m)
Up to 15000 ft (4570 m)
AC input voltage
100 to 127/200 to 240 VAC (autoranging) 50 to 60 Hz
100 to 127/200 to 240 VAC (autoranging) 50 to 60 Hz
DC input voltages
+5V
Environmental Ranges Operating temperature
Power Requirements
@9A, +12V
@0.5A +5V
@12A, +12V
@0.75A
+5V @22A, +12V @0.75A (with two modules installed) Power consumption
70W (maximum) 239 Btus per hour
90W (maximum) 307 Btus per hour 170W (with two modules installed) 580 Btus per hour
Physical Dimensions Weight
7 lb (3.2 kg)
14 lb (6.3 kg) 15.5 lb (7.1 kg with two modules installed)
Dimensions (H x W x D)
A-2
1.73 x 17.5 x 9.79 in. (4.4 x 44.5 x 24.8 cm)
Catalyst 2900 Series XL Installation Guide
3.46 x 17.5 x 12 in. (8.8 x 44.5 x 30.5 cm)
Page 3
Table A-2
Technical Specifications for the Catalyst 2924 XL and Catalyst 2924C XL Switches Catalyst 2924 XL
Catalyst 2924C XL
32 to 113°F (0 to 45°C)
32 to 113°F (0 to 45°C)
Storage temperature
–4 to 149°F (–10 to 65°C)
–4 to 149°F (–10 to 65°C)
Operating humidity
10 to 85% (noncondensing)
10 to 85% (noncondensing)
Operating altitude
Up to 10000 ft (3000 m)
Up to 10000 ft (3000 m)
Storage altitude
Up to 15000 ft (4570 m)
Up to 15000 ft (4570 m)
AC input voltage
100 to 127/200 to 240 VAC (autoranging) 50 to 60 Hz
100 to 127/200 to 240 VAC (autoranging) 50 to 60 Hz
DC input voltages
+5V
Power consumption
70W (maximum)
70W (maximum)
239 Btus per hour
239 Btus per hour
Weight
7 lb (3.2 kg)
7 lb (3.2 kg)
Dimensions (H x W x D)
1.73 x 17.5 x 9.79 in. (4.4 x 44.5 x 24.8 cm)
1.73 x 17.5 x 9.79 in. (4.4 x 44.5 x 24.8 cm)
Optical transmitter wavelength, 1300 nm1
Optical sensibility of the receiver, –14 dBm2
Optical power transmitter, –19 dBm to –14 dBm
Transmit, –19 dBm to –14 dBm
Environmental Operating Ranges Operating temperature
Power Requirements
@9A, +12V
@0.5A
+5V
@9A, +12V
@0.5A
Physical Dimensions
Fiber-Port Power Levels
1 2 nm = nanometers dBm = decibel milliwatt
Technical Specifications A-3
Page 4
Table A-3
Technical Specifications for the Catalyst 2924M XL Switch Catalyst 2924M XL
Environmental Operating Ranges Operating temperature
32 to 113°F (0 to 45°C)
Storage temperature
–4 to 149°F (–10 to 65°C)
Operating humidity
10 to 85% (noncondensing)
Operating altitude
Up to 10000 ft (3000 m)
Storage altitude
Up to 15000 ft (4570 m)
Power Requirements AC input voltage
100 to 127/200 to 240 VAC (autoranging) 50 to 60 Hz
DC input voltages
+5V
@12A, +12V
@0.55A
+5V @22A, +12V @0.75A (with 2 modules installed) Power consumption
90W (maximum) 307 Btus per hour 170W (with two modules installed) 580 Btus per hour
Physical Dimensions Weight
13.5 lb (6.12 kg) 15 lb (6.8 kg with two modules installed)
Dimensions (H x W x D)
A-4
3.46 x 17.5 x 12 in. (8.8 x 44.5 x 30.5 cm)
Catalyst 2900 Series XL Installation Guide
Page 5
Table A-4
Catalyst 2900 Series XL Agency Approvals
Safety
EMI
UL 1950/CSA 22.2 No. 950
FCC Part 15 Class A
IEC 950/EN 60950
EN 55022 Class A (CISPR 22 Class A)
AS/NZS 3260, TS001
VCCI Class A
CE
AS/NZS 3548 Class A BCIQ CE
Technical Specifications A-5
Page 6
A-6
Catalyst 2900 Series XL Installation Guide