Page 31

Chapter 2

Installing the Access Point Mounting Overview

Step 7

Attach the cables to the access point.

Note

Step 8

When the access point is powered up and is associated with a controller (Power LED is green, Alarm LED is off, and the radio LEDs are blinking), the access point is broadcasting its beacon.

Repeat the these steps for each access point on a horizontal surface. After mounting all horizontal surface access points, return to deploying the access points, "Step 3-c" on page 2-7.

c

Mounting Access Points Using the Ceiling-Mount Clips When you are mounting the access point under a suspended ceiling, use the ceiling-mount clips to mount the access point to the suspended ceiling rails. Attaching the Ceiling-Mount Clips to the Access Point

135665

Figure 2-8

Follow these steps to attach the ceiling-mount clips to the access point and mount the access point to suspended ceiling rails: Step 1

Copy the MAC address from the label on the access point onto the corresponding location on the access point location map. MAC addresses have the format 00xxxxxxxxxx.

Step 2

Attach the ceiling-mount clips to the bottom of the access point using the factory-supplied machine screws and washers (see Figure 2-8).

Cisco Aironet 1000 Series Lightweight Access Point Hardware Installation Guide OL-9403-04

2-11

Page 32

Chapter 2

Installing the Access Point

Mounting Overview

Step 3

Snap the ceiling-mount clips onto a suspended ceiling rail (see Figure 9). Ensure you leave enough space around the access point to plug the Ethernet cable, optional external antenna cable(s), optional power supply cable, and optional Kensington MicroSaver security cable into the sides of the access point. Mounting the Access Point with Ceiling-Mount Clips to a Suspended Ceiling Rail

135674

Figure 9

Step 4

Step 5

Attach the cables (Ethernet and optional antennas) to the sides of the access point.

Note

Ensure that the cables are routed away from the access point integrated antennas.

Note

When the access point is powered up and is associated with a controller (Power LED is green, Alarm LED is off, and the radio LEDs are blinking), the access point radios are operational and broadcasting their beacons.

Repeat Steps 1 to 4 for each suspended ceiling access point location. After mounting all suspended ceiling access points, return to deploying the access points, "Step 3-c" on page 2-7.

Cisco Aironet 1000 Series Lightweight Access Point Hardware Installation Guide

2-12

OL-9403-04

Page 33

Chapter 2

Installing the Access Point Mounting Overview

Mounting the Access Point Using a Projection Wall Mount Bracket When you are mounting the access point out from a vertical wall (flat sides along the wall or hallway), use an optional factory-orderable projection-mount L-bracket (see Figure 2-6). Follow these steps to attach the access point to the projection-mount bracket and mount the access point to a vertical wall: Before proceeding, gently screw the two factory-supplied screws and spring washers into the bottom of the access point (see Figure 2-10). Ensure the spring washers have their convex (high center sections) pointing toward the screw heads.

Note

Do not tighten the screw heads flush with the access point surface or the bracket will not fit under the screw heads.

Figure 2-10

Attaching the Mounting Screws to the Access Point

A. Screws and spring washers

B. Completed assembly

135667

Step 1

Step 2

Copy the MAC address(es) from the label(s) on the access point onto the corresponding location on the access point location map. MAC addresses have the format 00xxxxxxxxxx.

Step 3

Find the required mounting location as identified on your access point location map.

Step 4

Use the projection-mount bracket to mark the four screw holes on the wall. Ensure to leave enough space around the access point and base to plug the CAT-5 cable, optional external antenna cable(s), optional power supply cable, and optional Kensington MicroSaver security cable into the sides of the access point.

Step 5

Mount the projection-bracket to the wall using four screws in the marked locations. Use appropriate screws and wall anchors (user supplied). Tighten the wall screws.

Step 6

Position the two screws in the base of the access point over the projection-bracket keyhole slots and slide the access point in the direction of the key slots (see Figure 2-11). If you are unable to attach the access point to the bracket, remove the access point and loosen the two access point screws.

Note

After attaching the access point to the bracket, tighten the screws until they securely hold the access point.

Cisco Aironet 1000 Series Lightweight Access Point Hardware Installation Guide OL-9403-04

2-13

Page 34

Chapter 2

Installing the Access Point

Mounting Overview

Attaching the Access Point to the Projection-Mount Bracket

135671

Figure 2-11

Step 7

Step 8

Attach the cables to the sides of the access point. The Ethernet cable, optional external antenna cable(s), optional power supply cable, and optional Kensington MicroSaver security cables can be routed through the large holes in the mounting bracket.

Note

Ensure that the cables are routed away from the access point integrated antennas.

Note

When the access point is powered up and is associated with a controller (Power LED is green, 2.4 GHz LED is yellow, and 5.4 GHz LED is amber), the access point is broadcasting its beacon.

Repeat Steps 1 to 7 for each projection-mount bracket location. After mounting all your projection-mount access points, return to deploying the access points, "Step 3-c" on page 2-7.

Cisco Aironet 1000 Series Lightweight Access Point Hardware Installation Guide

2-14

OL-9403-04

Page 35

Chapter 2

Installing the Access Point Mounting Overview

Mounting the Access Point Using the Flush-Mount Bracket When mounting the access point against a vertical wall (flat side toward the inside of the building), use an optional factory-orderable flush-mount bracket. Follow these steps to mount the bracket and attach the access point: Step 1

Before proceeding, gently screw the two factory-supplied screws and spring washers into the bottom of the access point (see Figure 2-10). Ensure the spring washers have their convex (high center sections) pointing toward the screw heads.

Note

Do not tighten the screw heads flush with the access point surface or the bracket will not fit under the screw heads.

Step 2

Copy the MAC address(es) from the label(s) on the access point onto the corresponding location on the access point location map. MAC addresses have the format 00xxxxxxxxxx.

Step 3

Find the required mounting location as identified on your access point location map.

Step 4

Use the flush-mount bracket to mark the four screw holes on the wall. Ensure to leave enough space around the access point and base to plug the CAT-5 cable, optional external antenna cable(s), optional power supply cable, and optional Kensington MicroSaver security cable into the sides of the access point.

Step 5

Mount the flush-mount bracket to the wall using four screws in the marked locations. Use appropriate screws and wall anchors (user supplied). Tighten the wall screws.

Step 6

Position the two screws in the base of the access point over the flush-mount bracket keyhole slots and slide the access point in the direction of the key slots (see Figure 2-12). If you are unable to attach the access point to the bracket, remove the access point and loosen the two access point screws.

Note

Ensure the side of the access point with the door is facing away from the wall. This ensures that the correct antenna is facing the building, and makes future upgrades easier.

Note

After attaching the access point to the bracket, tighten the screws until they securely hold the access point.

Cisco Aironet 1000 Series Lightweight Access Point Hardware Installation Guide OL-9403-04

2-15

Page 36

Chapter 2

Installing the Access Point

Mounting Overview

Attaching the Access Point to the Flush-Mount Bracket

135672

Figure 2-12

Step 7

Step 8

Attach the cables to the sides of the access point (the Ethernet cable, optional external antenna cable(s), optional power supply cable, and optional Kensington MicroSaver security cable).

Note

Ensure that the cables are routed away from the access point integrated antennas.

Note

When the access point is powered up and is associated with a controller (Power LED is green, Alarm LED is off, and the radio LEDs are blinking), the access point is broadcasting its beacon.

Repeat Steps 1 to 7 for each flush-mount bracket location. After mounting all your flush-mount access points, return to deploying the access points, "Step 3-c" on page 2-7.

Cisco Aironet 1000 Series Lightweight Access Point Hardware Installation Guide

2-16

OL-9403-04

Page 37

Chapter 2

Installing the Access Point Securing the Access Point Using a Security Cable

Securing the Access Point Using a Security Cable You can secure the access point by installing a standard security cable (such as the Kensington MicroSaver, model number 64068) into the access point security cable slot (see Figure 2-3). The security cable can be used with any of the mounting methods described in this guide provided the cable can be secured to a nearby immovable object. Follow these steps to install the security cable. Step 1

Loop the security cable around a nearby immovable object.

Step 2

Insert the key into the security cable lock.

Step 3

Insert the security cable latch into the security key slot on the access point.

Step 4

Rotate the key right or left to secure the security cable lock to the access point.

Step 5

Remove the key from security cable lock.

Step 6

Repeat Steps 1 to 4 for each access point requiring a security cable. After securing your access points, go to the “Connecting to an Ethernet Network with an Inline Power Source” section on page 2-18.

Connecting the Ethernet and Power Cables The access point receives power through the Ethernet cable or an external power module.

Warning

This product must be connected to a Power over Ethernet (PoE) IEEE 802.3af compliant power source or an IEC60950 compliant limited power source. Statement 353

Caution

This product and all interconnected equipment must be installed indoors within the same building, including the associated LAN connections (as defined by Environment A of the IEEE 802.3af standard). The access point power options: •

Option 1 - Switches with sufficient inline power: – An inline power capable switch, such as the Cisco Catalyst 3550 PWR XL, 3560-48PS,

3750-48PS, 4500 with 802.3AF PoE module, or the 6500 with 802.3AF PoE module – Other inline power switches supporting the IEEE 802.3af inline power standard •

Option 2 - Switches without sufficient inline power can use the power injector: – Cisco Aironet Power Injector (AIR-PWRINJ-1000AF=)

•

Option 3 - Local power using the power module (AIR-PWR-1000=)

Cisco Aironet 1000 Series Lightweight Access Point Hardware Installation Guide OL-9403-04

2-17

Page 38

Chapter 2

Installing the Access Point

Connecting the Ethernet and Power Cables

Note

Some older switches and patch panels might not provide enough power to operate the access point. At power-up, if the access point is unable to determine that the power source can supply sufficient power, the access point automatically deactivates both radios to prevent an over-current condition. All access LEDs are off.

Connecting to an Ethernet Network with an Inline Power Source Note

If your access point is connected to in-line power, do not connect the power module to the access point. Follow these steps to connect the access point to the Ethernet LAN when you have an inline power source:

Step 1

Connect a Category 5 Ethernet cable to the RJ-45 Ethernet connector labeled Ethernet on the access point (see Figure 2-13). Figure 2-13

Ethernet and Power Ports

48 v 250Ma

1

1 Step 2

Step 3

Ethernet port

Ethernet

146974

24 GHz Left

2

2

48 VDC power port

Connect the other end of the Ethernet cable to one of the following: •

A switch with inline power (see the “Connecting the Ethernet and Power Cables” section on page 2-17).

•

The Ethernet connector on the power injector (AIR-PWRINJ-1000AF) labeled J1 DATA & PWR. Also connect a Category 5 Ethernet cable from the power injector Ethernet connector labeled J2 DATA to a non-powered Ethernet port on your 10/100 Ethernet LAN.

Repeat Steps 1 to 2 for each access point requiring in-line power.

Cisco Aironet 1000 Series Lightweight Access Point Hardware Installation Guide

2-18

OL-9403-04

Page 39

Chapter 2

Installing the Access Point Powering Up the Access Point

Connecting to an Ethernet Network with Local Power Note

If your access point is connected to in-line power, do not connect the power module to the access point. Follow these steps to connect the access point to an Ethernet LAN when you are using a local power source:

Step 1

Connect a Category 5 Ethernet cable to the RJ-45 Ethernet connector labeled Ethernet on the access point (see Figure 2-13).

Step 2

Plug the other end of the Ethernet cable into an non-powered Ethernet port on your 10/100 Ethernet LAN.

Step 3

Connect the power module output connector to the access point’s 48-VDC power port (see Figure 2-13).

Step 4

Plug the power module power cord into an approved 100- to 240-VAC outlet.

Powering Up the Access Point After you power up the access point, it begins a power-up sequence that you can check by observing the access point LEDs. The red Alarm LED turns on for about 15 to 20 seconds and then all LEDs blink sequentially back and forth, indicating that the access point is trying to find a controller. Refer to “Checking the Access Point LEDs” section on page 3-3 for LED descriptions. After the access point finds the controller, the access point downloads new operating system code if the access point code version differs from the controller code version. During the download process, all access point LEDs blink simultaneously. When the operating system download is successful, the access point reboots. Normal operation is indicated when the Alarm LED is off, the Power LED is green, and the 2.4 GHz and 5 GHz LEDs are blinking to indicate radio activity. If no LEDs are on, the access point might not be receiving sufficient power. If all the LEDs blink sequentially for more than five minutes, the access point is unable to find its primary, secondary, or tertiary controllers. Check the connection between the access point and its controllers and ensure they are on the same subnet or that the access point has a route back to its primary, secondary, and tertiary controllers. If the access point is not on the same subnet as the controllers, ensure there is a properly configured DHCP server on the same subnet as the access point. See the “Using DHCP Option 43” section on page 3-2 for DHCP information.

Note

To allow client roaming between access points, the access points must be on the same subnet.

Note

Connect only one power source to the access point, for example: When using in-line power, do not connect the power module to the access point.

Cisco Aironet 1000 Series Lightweight Access Point Hardware Installation Guide OL-9403-04

2-19

Page 40

Chapter 2

Installing the Access Point

Returning MAC Information

Returning MAC Information When you have completed the access point deployment, return the access point MAC addresses and the access point locations on the access point location maps or floor plans to your network planner or manager. The network operators can use the MAC address and location information to create maps for precise wireless system management.

Cisco Aironet 1000 Series Lightweight Access Point Hardware Installation Guide

2-20

OL-9403-04