Page 11
The Root Unit will have registration information for all nodes on the radio network in the tree.
Optional long range antennas are shown below; a range of 6 miles can be achieved with the 900MHz Yagi and 4 Miles with the 2.4GHz Yagi.
3
Page 12
Installing the Hardware With the unit powered off, attach the RP-TNC antenna to the antenna connector.
Do not over-tighten when connecting, finger-tight is sufficient. Once connected, make sure the antenna is positioned vertically to achieve an omni-directional pattern. Attach the console port cable to the EIA-232-E port and the other end of the cable to the serial port on a terminal, or PC running a terminal emulation program.
4
Page 13
If using Thinnet cabling, attach the cable to each end of a BNC T-connector, if applicable, then slide the T-connector onto the unit’s 10Base2 BNC connector.
If the Access Point is at the end of the Ethernet cable, a 50ohm terminator must be installed on the open end of the Tconnector. If using 10Base5 (Thicknet) cabling, attach the Transceiver Connector to the unit’s 10Base5 AUI Port. Slide the locking mechanism in place. The other end of the Transceiver drop cabling should connect to an External Transceiver.
5
Page 14
If using 10BaseT (Twisted Pair) cabling, plug the RJ-45 connector into the 10BaseT (Twisted Pair) socket and connect the other end of the cabling to a Twisted Pair hub or concentrator.
Insert the small plug on the end of the AC/DC Power Pack Cord into the 12-18VDC port, then plug the AC/DC power pack into an electrical outlet.
Power-on the Access Point by pushing the ON button.
6
Page 15
When power is initially applied to the Access Point, all three Indicators will flash yellow, red and then green, in sequence, to test the functionality of the Indicators. The Power-On Self Test follows. If any power-on test fails, the Status Indicator will go solid red and the unit will stop functioning.
7
Page 16
Configuring the Access Point To configure the Access Point to communicate with end nodes or repeaters, you must first use the Console Port to set the following parameters - SID, Bitrate/Frequency (or Channel), Root Mode. If you set an IP address now, you will be able to Telnet to the unit. The Console Port can be accessed directly by connecting the Access Point to an EIA-232-E terminal emulation program or by running a Telnet session from a remote on a network.
Console Port To start the Console Port, set the EIA-232-E terminal (or PC running a terminal emulation program) to 9600 Baud, NoParity, 8 data bits and 1 stop bit. Power-on the Access Point and the terminal and then type Yes or No when prompted for the ANSI or Teletype command. The Console Port consists of a main menu and a series of sub-menus containing the configuration parameters. Simply type the name of the parameter or the menu number and then press ENTER.
Telnet Session Telnet sessions can be disabled under Configuration Console Telnet Off Before starting a Telnet session to a remote Access Point, you must first assign the unit an IP Address. 8
Page 17
From the Main Menu, type Configuration Ident Inaddr and then type the applicable address.
System Identifier (SID) The SID is a unique identifier that is attached to each packet sent out over the radio. You must make sure that the Access Point is set with the same SID as the other nodes on the network with which you would like to share RF communication. You can either set your own SID or ask the unit to pick a random value for you. This is probably the best way to pick a SID as there is less chance of conflicting with other networks that may be in radio range. You may use only one unit to pick the random value. This same value must be used on all other devices on this system. At the Console Port, type Configuration Radio SID and then enter an even HEX number not exceeding 6 digits, or select random if you want the Access Point to pick the SID.
Bitrate/Frequency (2000 Series/2.4 GHz Models) The bit rate and frequency must match those of other nodes on the RF network. The default bit rate is the highest available, and the default frequency is the center frequency. You can accept these defaults or change them as follows. Type Bitrate and then type the applicable bit rate from the choices shown. Type Frequency and then type the applicable frequency from the choices shown.
9
Page 18
Channel (1000 Series/900MHz Models) The channel must match that of other nodes on the RF network. The default channel is the center frequency with the highest data rate. Since each channel is matched to a bit rate, changing the channel will also change the bit rate. Type Channel and then type the applicable channel from the choices shown. See Appendix D in the AP1000-E/AP2000-E Technical Reference Manual for more details.
Root Mode If your Access Point is serving as a repeater (no connections to the backbone) you should set root mode to “Off” as follows: Type Configuration-Radio-Root and then type “Y” in response to the argument prompt.
Verifying Registration Once you have configured your Access Point with the correct parameters and the end nodes are correctly configured, RF communication may begin. The Radio Indicator will flash “green” indicating RF data traffic. The Status Indicator will be “solid green” indicating that one or more nodes have registered to the unit.
10
Page 19
Where to Go from Here Please ask your Aironet representative for the AP1000-E/AP2000-E Technical Reference Manual. In the Technical Reference Manual, you can learn more details about your Aironet unit and ARLAN software. Use the instructions in this reference to view statistics and perform system diagnostics.
Technical Support Shipping Address Aironet Wireless Communications, Inc. 367 Ghent Road, Suite 300 Fairlawn, Ohio 44333
Communications Telephone - (800) 705-5555 Fax - (330) 664-7990 e-mail - techsupp@aironet.com