Page 21

Matrix 25 Length Code

Enable < Disable >

UPCA Length Code

Enable < Disable >

UPCE Length Code

Enable < Disable >

EAN8 Length Code

Enable < Disable >

EAN13 Length Code

Enable < Disable >

Code 93 Length Code

Enable < Disable >

Update

19

Page 22

Code 128 Length Code

Enable < Disable >

EAN128 Length Code

Enable < Disable >

MSI Length Code

Enable < Disable >

Plessey Length Code

Enable < Disable >

PDF417 Length Code (4 Digits)

Enable < Disable >

20

Enter Setup

Page 23

Select Readable Codes Code 39

< Enable > Disable

Italy Pharmacode

Enable < Disable >

French Pharmacode

Enable < Disable >

Industrial 25

< Enable > Disable

Interleave 25

< Enable > Disable

Update

21

Page 24

Matrix 25

Enable < Disable >

Codabar

< Enable > Disable

Code 93

< Enable > Disable

Code 128

< Enable > Disable

EAN128

Enable < Disable >

MSI

Enable < Disable >

22

Enter Setup

Page 25

Plessey

Enable < Disable >

UPCA

< Enable No Addon > Disable No Addon Enable Addon2 < Disable Addon2 > Enable Addon5 < Disable Addon5 >

UPCE

< Enable No Addon > Disable No Addon Enable Addon2 < Disable Addon2 > Enable Addon5 < Disable Addon5 >

Update

23

Page 26

EAN8

< Enable No Addon > Disable No Addon Enable Addon2 < Disable Addon2 > Enable Addon5 < Disable Addon5 >

EAN13

< Enable No Addon > Disable No Addon Enable Addon2 < Disable Addon2 > Enable Addon5 < Disable Addon5 >

24

Enter Setup

Page 27

Code39 Parameters Standard / Full ASCII Code39

< Standard > Full ASCII

Start / Stop Transmission

Enable < Disable >

Checksum Verification

Enable < Disable >

Checksum Transmission

< Enable > Disable

Italy Pharmacode Parameters Checksum Transmission

< Enable > Disable>

Update

25

Page 28

French Pharmacode Parameters Checksum Transmission

< Enable > Disable

Industrial 25 Parameters Start / Stop Selection

< Industrial 25 > Interleave 25 Matrix 25

Checksum Verification

Enable < Disable >

Checksum Transmission

< Enable > Disable

26

Enter Setup

Page 29

Max / Min Code Length Qualification

Select Max / Min Length Qualification

Max Length * Min Length *

Fixed Code Length Qualification

Select Fixed Length Qualification

Fixed Length 1 * Fixed Length 2 * Programming Instructions : (1) Read the label. (2) Program the desired length by reading Decimal Digits on page 51. (3) Read the “Validate” label (also on page 51) to complete this setting.

Interleave 25 Parameters Start / Stop Selection

Industrial 25 < Interleave 25 > Matrix 25

Update

27

Page 30

Checksum Verification

Enable < Disable >

Checksum Transmission

< Enable > Disable

Max / Min Code Length Qualification

Select Max / Min Length Qualification

Max Length * Min Length * Programming Instructions : (1) Read the label. (2) Program the desired length by reading Decimal Digits on page 51. (3) Read the “Validate” label (also on page 51) to complete this setting.

28

Enter Setup