Page 20

Terminal Components

QTERM-G70 Terminal

Touch keys can also be defined in your user applications at any location on or around the display. Touch keys may be any size.

1.3.2 Keyboard Using the optional PS/2 port, a standard PC keyboard may be used in addition to, or in place of, the touch screen. Power On Setup, the terminal setup utility, recognizes both touch keys and keyboard keys.

1.3.3 Keypad The QTERM-G70 terminal can optionally include electronics for attaching an external keypad with up to 8 columns by 8 rows and up to 6 keypad LEDs. Contact Beijer Electronics for more information. The keypad option will add 10 mA to the total current draw of the terminal plus the current driven out the LED outputs pins. The LED outputs are five-volt open-collector signals with a 1000 Ohm series resistor. This results in an approximate maximum output current drive of 5 mA on those pins. There are two connectors on the keypad module to facilitate connecting different sized keypads. The pinouts for those connectors are shown in the following tables.

8

1 2 3 4 5 6 7 8

Connector J1 - 0.1 Inch Pitch 16-pin Single-row Connector GND 9 LED 1 10 Row 1 11 Row 2 12 Row 3 13 Row 4 14 GND 15 LED 2 16

Row 5 Row 6 Col 1 Col 2 Col 3 Col 4 Col 5 Col 6

1 2 3 4 5 6 7 8

Connector J2 - 0.1 Inch Pitch 24-pin Dual-row Connector Row 1 13 5 V or 3.3 V 14 Row 2 15 GND 16 Row 3 17 LED 6 18 Row 4 19 LED 5 20

Col 1 LED 4 Col 2 LED 3 Col 3 LED 2 Col 4 LED 1

Qlarity-Based Terminal Hardware

Page 21

QTERM-G70 Terminal

Terminal Components

9 10 11 12

Connector J2 - 0.1 Inch Pitch 24-pin Dual-row Connector Row 5 21 Row 8 22 Row 6 23 Row 7 24

Col 5 Col 6 Col 8 Col 7

1.3.4 Speaker A speaker is built into the QTERM-G70 terminal and faces to the back of the unit. Audio can be linked to events or actions (e.g., screen press, timer, etc.). Pitch and duration of a sound are controlled by API functions called from the user application. Refer to “Controlling the Speaker” section in the Qlarity-based Terminal Programmer's Reference Manual. Optionally, an audio (.wav) decoder can be added to the QTERM-G70 to allow the speaker to play audio files. The audio decoder supports wave files meeting the following criteria:

• Sample rate of 8 kHz, 11.025 kHz, 16 kHz or 22.050 kHz • Resolution of 8 or 16 bits per sample. The audio decoder circuit amplifies the signal to 0.5 W rms at the speaker.

1.3.5 Real-Time Clock The QTERM-G70 terminal is equipped with a battery-backed, real-time clock. The real-time clock can be used to time/date stamp messages or for timed polling and program execution.

WARNING There may be danger of leakage if the battery is incorrectly replaced, creating a potential health hazard. Replace the battery only with the same (CR1220) or equivalent type as recommended by the manufacturer. Dispose of used batteries according to the manufacturer’s instructions.

1.3.6 System Memory The QTERM-G70 terminal stores the firmware and user applications in a compressed format in flash memory and then transfers them to RAM memory when the terminal is powered on. Four megabytes of flash memory and sixteen megabytes of RAM memory are standard. For information on using resources efficiently to conserve memory when creating a user application, refer to “Edit Resources” section in the Qlarity Foundry User Guide.

Qlarity-Based Terminal Hardware

9

Page 22

Installing to NEMA-4

QTERM-G70 Terminal

For information on downloading new firmware, downloading a user application, and determining the size of a user application, refer to the Qlarity Foundry User Guide.

1.3.7 Watchdog Timer A watchdog timer can be added to enforce proper operation of the QTERM-G70. The watchdog timer will reset the terminal if there is a problem that causes the firmware to lock up. This does not apply to software deadlocks in the Qlarity code. If that is required, then the Qlarity watchdog timer should be used, using the WatchdogEnable and WatchdogReset APIs.

1.4 Installing to NEMA-4 A QTERM-G70 terminal uses a rugged, glass-filled polyester (UL 94V-0) case designed to mount into a panel or drywall. When properly installed in a NEMA-4 rated panel, the QTERM-G70 meets all NEMA-4 specifications including hose-down, icing, and salt spray. A QTERM-G70 terminal can be installed in either a landscape or portrait orientation. When installing a terminal, you generally take the following steps.

• Decide whether you want to mount and use the terminal in a portrait or landscape orientation. “Portrait” means that the longest dimension is vertical; “landscape” means that the longest dimension is horizontal.

• Cut a hole in the panel or drywall. See section 1.4.1, “Cutout for Panel Mount Configuration” or section 1.4.3, “Cutout for Drywall Mount Configuration” for specifications.

• Install the QTERM-G70 terminal in the panel or drywall. See section 1.4.2, “Installing the Panel Mount Terminal” or section 1.4.4, “Installing the Drywall Mount Terminal” for instructions.

• Connect cables to the terminal. Verify that the thumb screws are tight or the locks snapped into place for each cable used.

• Apply DC power to the QTERM-G70 terminal. See section 1.4.5, “Applying Power” for information.

1.4.1 Cutout for Panel Mount Configuration The QTERM-G70 terminal can be mounted in panels from 0 to 7 mm thick. No screw holes need to be drilled to install the terminal in the panel. Make a rectangular hole in the panel using the following dimensions. Landscape Horizontal: 199 ± 1 mm Vertical: 145 ± 1 mm

10

Portrait Horizontal: 145 ± 1 mm Vertical: 199 ± 1 mm

Qlarity-Based Terminal Hardware

Page 23

QTERM-G70 Terminal

Installing to NEMA-4

Figure 5 is a diagram of the landscape cutout.

Figure 5 QTERM-G70 Landscape Cutout File any rough edges smooth, especially on the face of the panel.

1.4.2 Installing the Panel Mount Terminal NOTE

☞

Use of an anti-static strap is recommended when performing installation and maintenance. Take the following steps to install the terminal. 1. Verify that the panel surface around the cutout is clean and free of rough edges. A gasket built into the terminal will seal against this surface. Dirt or imperfections on the panel may prevent a proper seal. 2. Place the terminal into the panel cutout and verify that the terminal is oriented correctly. The touch screen legend may indicate the orientation. If not, you can determine which side should be at the top by the position of the serial port on the back panel as follows:

• Landscape When looking at the front of the unit, the back panel serial port(s) should be on the bottom of the terminal.

• Portrait When looking at the front of the unit, the back panel serial port(s) should be on the left side of the terminal. Refer to Figure 6.

Qlarity-Based Terminal Hardware

11

Page 24

Installing to NEMA-4

QTERM-G70 Terminal

Figure 6 QTERM-G70 Front Panel Mount 3. On the back of the panel, place the terminal mounting bracket against the back of the terminal, and align it with the back panel. Refer to Figure 7.

Figure 7 QTERM-G70 Back Panel Mount 4. Fasten the six screws (supplied with the terminal).

12

Qlarity-Based Terminal Hardware

Page 25

QTERM-G70 Terminal

Installing to NEMA-4

1.4.3 Cutout for Drywall Mount Configuration The QTERM-G70 terminal with the drywall mount configuration will accommodate drywall thicknesses of 7 mm to 18 mm. The panel may be cut by using the template supplied with the unit or by using the dimensions given below. To use the template, simply identify where the unit is to be placed on the wall and tape the template up into position. Next cut along the indicated line. The cutout dimensions with appropriate tolerances are as follows. Landscape Horizontal: 199 ± 1 mm Vertical: 145 ± 1 mm NOTE

☞

Portrait Horizontal: 145 ± 1 mm Vertical: 199 ± 1 mm

Care must be taken not to make the cutout oversize.

1.4.4 Installing the Drywall Mount Terminal NOTE

☞

Use of an anti-static strap is recommended when performing installation and maintenance. Take the following steps to install the terminal. Refer to Figure 8.

Figure 8 QTERM-G70 Drywall Mount 1. Verify that the unit is in the correct orientation. The touchscreen legend may indicate the orientation. If not, the top side may be identified by the position of the serial port(s) on the back panel as follows:

Qlarity-Based Terminal Hardware

13

Page 26

Installing to NEMA-4

QTERM-G70 Terminal

• Landscape When looking at the front of the unit, the back panel serial port(s) should be on the bottom of the terminal.

• Portrait When looking at the front of the unit, the back panel serial port(s) should be on the left side of the terminal. 2. Connect all necessary cables to their correct places on the back panel. 3. Insert the terminal into the cutout in the wall. If the unit will not fit into the opening, check to make sure that the cam locks on the top and bottom are not protruding from the case. 4. Tighten all four screws on the front panel until the unit seats firmly in the cutout. The screws should be tightened approximately 2-3 full turns after a slight resistance is felt. NOTE

☞

Do not over tighten the screws. Doing so will damage the cam locks and the unit will no longer mount securely into the wall. 5. Using the supplied legend, remove the adhesive back and install on the front of the unit over the top of the four screws as indicated in the figure.

1.4.4.1 Removing the Drywall Mount Terminal Removal of the G70 terminal requires the replacement of the outer legend. Replacements may be ordered from Beijer Electronics. 1. Remove the outer legend on the front of the unit to expose the four mounting screws. 2. Turn the screws counterclockwise until they begin to back out of the unit. 3. Gently pull the terminal from the wall cutout.

1.4.5 Applying Power Power is supplied to the QTERM-G70 terminal via the primary serial port connector. Refer to section 1.2.1, “Serial Ports” for power and ground pin assignments. DC power must be in the range of 8 to 26 volts (the current will vary depending on the input voltage; see table below). QTERM-G70 power must come from an SELV (Safety Extra Low Voltage) power source

CAUTION and should have a current limit on its output of 5 Amperes. It must provide a minimum of 8 volts DC power and be limited to a maximum of 26 volts DC. Limiting may be inherent to the supply or may be provided by supplementary overcurrent devices. If the QTERM-G70 does not respond or exhibits abnormal behavior on power up, disconnect power and contact Beijer Electronics for technical support.

14

Qlarity-Based Terminal Hardware

Page 27

QTERM-G70 Terminal

Powering On the Terminal for the First Time

Current Consumption Terminal

12 VDC

24 VDC

PoE

Standard unit (color, no options, idle)

400 mA

240 mA

120 mA

Standard TFT unit (TFT, no options, idle)

675 mA

350 mA

190 mA

Standard unit, active add 90 mA add 40 mA add 15 mA

Standard TFT unit, active add 90 mA add 50 mA add 15 mA

With keyboard option and keyboard attached add 70 mA add 35 mA

N/A

With Ethernet option and connection add 40 mA add 20 mA

N/A

1.5 Powering On the Terminal for the First Time When you connect power to the QTERM-G70 terminal, it automatically loads the application saved in flash memory into RAM memory and executes the application. If no application is present, the terminal display may be blank but the backlighting verifies it is powered on. When you power on the terminal for the first time, a demo application (or a special application custom designed for your company) loads. The demo application will help you verify that the terminal is operating properly. Follow the on-screen prompts or any documentation accompanying the program to guide you through tests or demonstrations designed to verify terminal operation. Once you have verified that the terminal is functioning properly, refer to Chapter 8, “Power On Setup” for information on configuring your terminal. The Power On Setup utility includes functions to do the following:

• Change orientation of the terminal (portrait or landscape) • Download a new user application to the terminal • Select the application mode • Set up communications settings for the terminal • Adjust display contrast or backlight • Enter network (Ethernet) settings • Enter/change password (if used) • Set the real-time clock

Qlarity-Based Terminal Hardware

15

Page 28

Powering On the Terminal for the First Time

QTERM-G70 Terminal

Notes

16