Browse
(440) 299-7778
Menu
(440) 299-7778
One-year parts and labor warranty30-day money-back guaranteeEnglishEspañolContact

The text of a manual · part 22 of 23

Owner's Manual: BayTech M Series DAC, pages 211 to 220

Pages 211 to 220 of 229

The original document is the PDF (499 KB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.

For the BayTech M3 DAC

Page 211

M SERIES DAC TECHNICAL SUPPORT ____________________________________________________________________________

Contact rating: VDC

3A @120 VAC, 2A @220 VAC or 28 resistive load

Contact resistance: Life expectancy:

100 milliohms initially Mechanical: 20 million operations (min) Electrical: 100,000 (min) @ full load

Vibration:

10g @ 55-110Hz, 0.062", Dual amplitude(DA) -55Hz

Shock:

10g

Voltage isolation:

500 Vrms Channel-Channel & Channel-Ground

Connector:

DB-25 female

Power Requirements: are on –

+5VDC, 300ma typical when all relays (provided by M16/M8 power supply).

Software Control:

Relays individually programmable to act upon, record and/or report events by time, or on demand. Operating temperature range 0o to 55o C Storage temperature range -55o to 85o C Humidity 5% to 95% non-condensing

Environmental:

V79 PDI-1 SWITCH INPUT STATUS MODULE NOTE: These values are typical for 25o C unless otherwise noted) Inputs:

16 with individual ground returns or common (single-point) ground.

Drive Distance:

Up to 1000 Ohms cable resistance, for example: AWG 36 - 2400 ft., AWG 24 -

15000 ft., AWG 22 - 62000 ft.

199

Page 212

M SERIES DAC TECHNICAL SUPPORT ____________________________________________________________________________

Power Requirements: M16/M8

+5VDC, 40 ma typical (provided by pwr supply).

Debounce: Environmental:

0 to 60000 ms (software selectable). Operating temperature range: 0o to 70o C Storage temperature range: -40o to 85o C Humidity: 5% to 95% non-condensing

V80 PDI-2 OPTICALLY ISOLATED INPUT MODULE

Module Type

PDI-2A PDI-2B

Number of Inputs:

16

16

Input Voltage Range:

5-24

100-130

Maximum Input Current:

50ma

20ma

Minimum Turn On Current:

8ma

8ma

Max Turn On Time:

1ms

1ms

Max Turn Off Time:

1ms

1ms

VOLTAGE ISOLATION: Power Requirements: M16/M8

AC/DC

500V 500V (Input to Input and Input to ground) +5VDC, 40 ma typical (provided by pwr supply)

Debounce Time:

0 to 60000 ms (software selectable)

Environmental:

Operating temperature range: 0o to 70o C Storage temperature range: -40o to 85o C Humidity: 5% to 95% non-condensing

V82 PCM-1 SPECIFICATIONS FACTORY POWER-UP DEFAULT CONFIGURATION: Channel Names: 200

MOD01P01 for Module 1 Channel 1 MOD01P02 for Module 1 Channel 2

Page 213

M SERIES DAC TECHNICAL SUPPORT ____________________________________________________________________________

. . . MOD16P16 for Module 16 Channel 16 Instruction Table:

The Instruction Table is blank by default. If an instruction is entered into the Instruction

Table, that instruction and the "latch" parameter are disabled by default. Program Strings:

All output strings are blank by default.

Conversion Tables:

All conversion tables are blank by default.

User-Programmable Configurations: are

Easy to configure using on-screen menu. Choices saved in non-volatile memory to become the new power-up default configuration. Channel Names:

Any character string up to 16 ASCII characters.

Instruction Table:

Up to 999 instructions can be entered. Each instruction can be enabled or disabled and given a name up to 8 ASCII characters. There are fields for Enable, Line Name, CMD Type, and 5 arguments for each instruction. Each instruction has a "latch" parameter that can be enabled or disabled. Program Strings:

Up to 64 ASCII strings can be programmed.

String Name:

Up to 8 ASCII characters.

String Content:

Up to 64 ASCII characters.

Conversion Tables: programmed.

Up to 16 conversion tables can be

Conversion Table Name:

Up to 8 ASCII characters. 201

Page 214

M SERIES DAC TECHNICAL SUPPORT ____________________________________________________________________________

Slope:

-9999.99 to +9999.99

Y-Intercept:

-9999.99 to +9999.99

Range:

Up to 5 linear ranges per conversion table.

V 93A SPECIFICATIONS

Interface:

Dial-up telephone line

Modulation:

V.32bis (14,400 bps) or V.32 (9600 bps)

Compression:

V.42bis, MNP5

Connectors:

2 x 4-pin modular

Module LEDS:

TD (Transmit Data), RD (Receive Data), CD (Carrier Detect), MR (Modem Ready), and CX (Connection) status LEDs. Transmit Level:

-10 dBm (dial-up)

Receiver Sensitivity:

-45 dBm

Dimensions:

6"h x 4.5"w.

202

Page 215

M SERIES DAC APPENDIX B ____________________________________________________________________________

APPENDIX B MODEM COMMAND SUMMARY U.S. ROBOTIC MODEMS COMMAND

INTERPRETATION

AT&B1

Fixed Serial Port Rate (default)

AT&C1

Normal CD Operations (default)

AT&D2

Normal DTR Operations (default)

ATSO=1

Auto answer telephone line in 4 or fewer rings

ATE0

Modem does not display keyboard commands.

ATQ1

Place modem into quiet mode

AT&W0

Save the modem’s configuration in non-volatile memory

NOTE: To send all of the above at the same time, type the following command: AT&B1&C1&D2S0=1E0Q1&W0

ROCKWELL CHIP SET MODEMS COMMAND

INTERPRETATION

ATS23=59

Fixed Serial Port Rate (default)

AT&C1

Normal CD Operations (default)

AT&D2

Normal DTR Operations (default)

ATS0=1

Auto answer telephone line in 4 or fewer rings

ATE0

Modem does not display keyboard commands

ATQ1

Place modem into quiet mode

AT&W0

Save modem’s configuration in non-volatile memory

NOTE: To send all of the above at the same time, type the following command: ATS23=59&C1&D2S0=1E0Q1&W0 203

Page 216

M SERIES DAC APPENDIX E ____________________________________________________________________________

APPENDIX C MODULE COMMAND SUMMARY V74/V75/V87 DAC DATA COMMAND SUMMARY Command

Description

$CONFIG<cr>

Full menu configuration command.

$BTBn<cr> (n=1 to 16)

Broadcast. This command puts module n into broadcast mode where data received by the host module is sent to all V74/V75/V76/V87 ports simultaneously.

CBn<cr> (n=1 to 4, 0=all)

Clear Buffer. This command clears all buffered messages from the specified ports.

ID<cr>

Port ID Status. This command reports the current Port ID status for the ports of the selected module. The Port ID can have the format of either UU:MM,PP (Unit:Module, Port) or the device name of the port.

RAn<cr> (n=1 to 4, 0=all)

Report All Buffered Messages. This command reports all messages in the buffer at the time the command was sent. If there are no messages, <lf> is sent to the host controller.

RBn<cr> (n=1 to 4, 0=all)

Report All Buffered Data. This command reports all data in the buffer at the time which the command was received with no regard for messages. If there is no data, <lf> is sent to the host controller.

* RESET<cr>

Reset. This command instructs the entire M Series system to do a software reset.

RSn<cr> (n=1 to 4, 0=all)

Report Single Message. This command reports a single buffered message. If there is no message, <lf> is sent to the host controller.

RT<cr>

Read Time. This command requests the base unit to send the current date and time.

SRn<cr> (n=1 to 4, 0=all)

Stop Report. This command stops data flow from an RBn or RAn command.

ST HH:MM:SS,MM/DD/YY<cr>

Set Time. This command programs the date and time of the base unit's time-of-day clock.

NOTE: Multiple V74/V75/V76/V87 ports are selected using 2 formats. Examples: RA1,2,3,4<cr> and RA0<cr>. * The RESET<cr> command must be issued from the service port or service modem.

204

Page 217

M SERIES DAC TECHNICAL SUPPORT ____________________________________________________________________________

V77 ADM-1 DATA COMMAND SUMMARY Command

Description

CAn<cr> (n=0 or 1 to 3)

Calibrate. 0=all, 1=25%, 2=50%, and 3=75% of Full Scale (FS). Initiates auto-calibration. ADM-1 tests for offsets and makes necessary corrections. Corrections are continually applied to all reported data messages until another Calibrate command is issued.

CBc<cr> (c=Ch# 1 to 16, 0=all)

Clear Buffer. Clears all old data from the buffer when a new data set is started.

RAc<cr> (c=Ch# 1 to 16, 0=all)

Report All Buffered Samples.

RS c<cr> (c=Ch# 1 to 16, 0=all)

Report Single Sample if Available

SAc<cr> (c=Ch# 1 to 16, 0=all)

Sample. Read and report sample at programmed setup.

V77 ADM-1 DYNAMIC CONFIGURATION COMMAND SUMMARY Command

Description

AVn<cr> (n=1 to 4,000)

Number of Samples to Average

DFn<cr> (n=1 or 2)

Data Format. 1=Hexadecimal and 2=Decimal.

RMn<cr> (n=1 to 3)

Reporting Method. 1=Command, 2=Immediate, and 3=Schedule.

SDn<cr> (n=1 or 2)

Single Ended/Differential. 1=single ended and 2=differential.

S Mn<cr> (n=1 or 2)

Sampling Method. 1=Command, 2=Immediate, and 3=Schedule.

SPn<cr> (n=1 or 2)

Sample Period. 1=Continuous and 2=Time.

SRn<cr> (n=1 to 4000)

Sample Rate (Samples/Sec)

TTn<cr> (n=1 or 2)

Time Tag. 1=Enable and 2=Disable.

UBn<cr> (n=1 or 2)

Unipolar/Bipolar. 1=unipolar and 2=bipolar.

VRn<cr> (n=1 to 5)

Set Voltage Range. 1 = +10V (with JP1 installed), 2 = +5V (or 0 to +10V), 3 = +2.5V (or 0 to +5V), 4 = +1.25V (or 0 to +2.5V) and 5 = +0.625V (or 0 to +1.25V)

205

Page 218

M SERIES DAC TECHNICAL SUPPORT ____________________________________________________________________________

V78 CRM-1 DATA COMMAND SUMMARY Command

Description

CBr<cr> (r=Relay# 1 to 8, 0=all*)

Clear Buffer. Clears all buffered relay status history (change of state).

DRr<cr> (r=Relay# 1 to 8, 0=all*)

De-energize Relay(s)

ERr<cr> (r=Relay# 1 to 8, 0=all*)

Energize Relay(s)

RAr<cr> (r=Relay# 1 to 8, 0=all*)

Report All Buffered Relay Status History

RS r<cr> (r=Relay# 1 to 8, 0=all*)

Report Single Relay Status History Sample if Available

SAr<cr> (r=Relay# 1 to 8, 0=all*)

Sample. Read and report the current status of the selected relay(s).

V78 CRM-1 I/O MODULE DYNAMIC CONFIGURATION COMMAND SUMMARY Command

Description

RMn<cr> (n=1 to 3)

Reporting Method. 1=Command, 2=Immediate, and 3=Schedule.

TTn<cr> (n=1 or 2)

Time Tag. 1=Enable and 2=Disable.

206

Page 219

M SERIES DAC TECHNICAL SUPPORT ____________________________________________________________________________

V79 PDI-1 & V80 PDI-2 COMMAND SUMMARY Command

Description

CBc<cr> (c=Ch# 1 to 16, 0=all)

Clear Event Buffer. Clear all buffered event samples.

CCc<cr> (c=Ch# 1 to 16, 0=all)

Clear Event Counter(s)

CRc<cr> (c=Ch# 1 to 16, 0=all)

Clear Event Latch Data

RAc<cr> (c=Ch# 1 to 16, 0=all)

Report All Buffered Events

RCc<cr> (c=Ch# 1 to 16, 0=all)

Report Event Counter(s)

RDc<cr> (c=Ch# 1 to 16, 0=all)

Report Event Duration(s)

RLc<cr> (c=Ch# 1 to 16, 0=all)

Report Event Latch Data

ROc<cr> (c=Ch# 1 to 16, 0=all)

Report Event Counter and Reset

RRc<cr> (c=Ch# 1 to 16, 0=all)

Report Event Latch Data

RS c<cr> (c=Ch# 1 to 16, 0=all)

Report Single Buffered Event (first in, first out)

SAc<cr> (c=Ch# 1 to 16, 0=all)

Read and report the current state of the selected input(s).

SLc<cr> (c=Ch# 1 to 16, 0=all)

Report Latest Event

* Multiple channels are selected using 4 formats. Examples: SA1,2,3,4,5,6,7,8<cr>, SA1-8<cr>, SA0<cr>, SA1,2,4-8<cr>

V79 PDI-1 & V80 PDI-2 DYNAMIC CONFIGURATION COMMAND SUMMARY Command

Description

DBn<cr> (n=0-65535ms)

Debounce Delay

DFn<cr> (n=1 or 2)

Data Format. 1=Hexadecimal and 2=Decimal.

RMn<cr> (n=1 to 3)

Reporting Method. 1=Command, 2=Immediate, and 3=Schedule.

TTn<cr> (n=1 or 2)

Time Tag. 1=Enable and 2=Disable.

207

Page 220

M SERIES DAC APPENDIX E ____________________________________________________________________________

APPENDIX D – CABLES AND ADAPTERS

208