Browse
(440) 299-7778
Menu
(440) 299-7778
One-year parts and labor warranty30-day money-back guaranteeEnglishEspañolContact

The text of a manual · part 20 of 23

Owner's Manual: BayTech M Series DAC, pages 191 to 200

Pages 191 to 200 of 229

The original document is the PDF (499 KB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.

For the BayTech M3 DAC

Page 191

M SERIES DAC BASE UNIT AND MODULE OPERATION ____________________________________________________________________________ commands are typically used to request stored data received from an I/O module. Data commands are also used to instruct certain I/O modules to perform a specific task (e.g., energize or de-energize a relay). The configuration menu is invoked by selecting configure(C) from the port selection menu. The supported configuration and data commands for a specific I/O module are described in the documentation for that module.

PORT SELECTION MENU To activate the port selection menu, type 5 or more ;;;;; (default) in a row and a menu similar to the following will appear. .

M-Series V93A DAC Host Unit 1 Module 2 REV. 4.00 Copyright(c) 1995-1997 Bay Technical Associates Device A (2,1)............1 Device B (2,2)............2 Device C (2,3)............3 Device D (2,4)............4 Configure.........................C Manual Mode.......................M Exit..............................X Unit Reset........................R Logout............................T Enter Request :

The device names in the menu correspond to the device names assigned to the serial ports installed in the unit. To select a particular device simply enter the number of the device then hit return. Refer to section 16.4 of the M-Series DAC owners manual for configuration of device names. The other items in the menu provide various functions described below:

179

Page 192

M SERIES DAC BASE UNIT AND MODULE OPERATION ____________________________________________________________________________

Configure - Allows users enter into the configuration mode for any installed modules or for the base unit. See Section 6 CONFIGURATION for details to configure the unit.

MANUAL MODE Manual Mode allows users to manually select a module and/or port. The “Manual Mode” selection for the V93A menu is used to make a module level connection which is used for sending commands to the module. The “Manual Mode” is used to make a connection to a module such as the Control Relay Module, A-to-D Module, Event Counter Module, main board, etc. Use the “Manual Mode” for module connections other than a Serial I/O module unless you want to operate a Serial I/O module in the Command Mode of operation. The “Manual Mode” selection should not be used for configuration. By responding to the Enter Request: message at the end of the V93A menu with “M” you receive a response similar to the following: Device A (2,1).................... 1 Device B (2,2).................... 2 Device C (2,3).................... 3 Device D (2,4).................... 4 Device A (3,1).................... 5 Device B (3,2).................... 6 Device C (3,3).................... 7 Device D (3,4).................... 8 Configure ............................... C Manual Mode ............................. M Exit......................................X Unit Reset .............................. R Logout .................................. T Enter Request:

M

Enter Module number: 2

180

Page 193

M SERIES DAC BASE UNIT AND MODULE OPERATION ____________________________________________________________________________

Enter Port number (<CR> for none): 3

By entering “2” at the Enter Module number and entering “3” at the Enter Port number, the user has selected module number 2 and port number 3. Verify the connection by insuring that the red LED of Port 3, Module 2 on the front panel of the M-Series DAC base unit has been selected.

EXIT By responding to the Enter Request : message in the V93A Status & Diagnostics Menu with “X” (Exit), you will exit the V93A Status & Diagnostics Menu. The V93A host module will respond with a menu that is similar to the following: >X

UNIT RESET Users can instruct the M-Series DAC with the V93A module, to “reset” by using the Menu Selection Method to reset the unit. The Unit Reset command does not affect any saved configuration parameters that have been changed from the default values. By responding to the Enter Request: message at the end of the menu with “R”(Unit Reset), you will reset the M-Series unit. Device A Device B Device C Device D Device A Device B Device C Device D

(2,1).................... 1 (2,2).................... 2 (2,3).................... 3 (2,4).................... 4 (3,1).................... 5 (3,2).................... 6 (3,3).................... 7 (3,4).................... 8

181

Page 194

M SERIES DAC BASE UNIT AND MODULE OPERATION ____________________________________________________________________________

Configure ............................... C Manual Mode ............................. M Exit......................................X Unit Reset .............................. R Logout .................................. T Enter Request:

R

The M-Series DAC unit has been reset. Important: The Unit Reset command will terminate communications with connected equipment to the M-Series DAC. You must re-establish communications with the M-Series DAC system after the unit has been reset. The Menu is invoked by sending the Attention Character(default ;;;;;) to the V93A host module five times. The V93A will respond with a menu similar to the following, if two Serial I/O modules are installed.

LOGOUT By responding to the Enter Request : message in the V93A Main Menu with “T” (Logout), you will take you out of menu mode If you have a modem connection it will terminate that connection. The V93A host module will respond with a message similar to the following: Device A Device B Device C Device D Device A Device B Device C Device D

(2,1).................... 1 (2,2).................... 2 (2,3).................... 3 (2,4).................... 4 (3,1).................... 5 (3,2).................... 6 (3,3).................... 7 (3,4).................... 8

Configure ............................... C Manual Mode...... ....................... M Exit......................................X Unit Reset .............................. R Logout .................................. T Enter Request:

182

Page 195

M SERIES DAC BASE UNIT AND MODULE OPERATION ____________________________________________________________________________

To return to the menu after making a connection, simply type 5 or more ‘;’ semicolons(default). NOTE: Menu selection is case sensitive.

183

Page 196

M SERIES DAC TECHNICAL SUPPORT ____________________________________________________________________________

TECHNICAL SUPPORT BayTech has a staff of applications engineers on duty to assist you from 7 a.m. to 6 p.m. (CST or CDT), Monday through Friday. If you have problems installing, setting up, or operating your Bay Tech product, please contact BayTech’s technical support office. For information on all of BayTech’s data communication products, contact our Web Site at the address shown below. If you call the BayTech support desk, please have the following information available to help the applications engineers answer your questions efficiently. Use the next page to record vital information. 1.

Identify which modules you are using and have the serial number handy (located on the back of the unit).

2.

Identify what host device and peripheral devices you have connected to the M Series unit.

3.

Determine the type of application you are using (e.g., the reporting and/or sampling method you are using).

4.

Identify what cables/adapters you are using, the lengths of the cable and who sold you the cables/adapters.

5.

Identify any special options you may have ordered.

6.

If possible, have a print-out of the unit's configuratio n status ready when you call. Bay Technical Associates, Inc. 200 N. Second Street, P. O. Box 387 Bay St. Louis, MS 39520-1000, USA Telephone: 800-523-2702 228-467-8231 FAX: 228-467-4551 Web Site: www.baytechdcd.com

184

Page 197

M SERIES DAC TECHNICAL SUPPORT ____________________________________________________________________________

185

Page 198

M SERIES DAC TECHNICAL SUPPORT ____________________________________________________________________________

EQUIPMENT SETUP MODULE 1

MODULE 2

MODULE 3

MODU

MODEL

MODEL

MODEL

MODEL

SERIAL NUMBER

SERIAL NUMBER

SERIAL NUMBER

SERIAL NUMBER

USE

USE

USE

USE

MODULE 5

MODULE 6

MODULE 7

MODU

MODEL

MODEL

MODEL

MODEL

SERIAL NUMBER

SERIAL NUMBER

SERIAL NUMBER

SERIAL NUMBER

USE

USE

USE

USE

MODULE 9

MODULE 10

MODULE 11

MODU

MODEL

MODEL

MODEL

MODEL

SERIAL NUMBER

SERIAL NUMBER

SERIAL NUMBER

SERIAL NUMBER

USE

USE

USE

USE

MODULE 13

MODULE 14

MODULE 15

MODU

MODEL

MODEL

MODEL

MODEL

SERIAL NUMBER

SERIAL NUMBER

SERIAL NUMBER

SERIAL NUMBER

USE

USE

USE

186

Page 199

M SERIES DAC TECHNICAL SUPPORT ____________________________________________________________________________

Type of adapters ___________________________________________________ ___ _________________________________________________________ _______________ Type of cables ___________________________________________________ ___ _________________________________________________________ _______________ Name of software program ________________________________________________ _________________________________________________________ _______________

187

Page 200

M SERIES DAC REPACKAGING, SHIPPING, AND RETURNING UNIT TO THE FACTORY ____________________________________________________________________________

REPACKAGING, SHIPPING AND RETURNING TO THE FACTORY If your Bay Tech unit needs service, upgrade, or repair, return it to BayTech. Before dismantling your equipment or before returning the unit for any reason, always call BayTech. The user should never attempt repairs on this unit. If you need to return the RPC Series to the factory for repair, warranty work, or upgrade, follow the instructions below for repackaging and shipping.

INSTRUCTIONS FOR REPACKAGING AND SHIPPING: a. Call BayTech to get a Return Authorization Number. IMPORTANT: Without this number, BayTech will not accept returns. b. Use the original packaging if available or choose a heavy cardboard box. c. Surround your unit with a minimum of two inches of insulation. d.

Be sure to seal the box securely with strapping or packing tape. We do not recommend masking tape or cellophane tape.

e. On the outside of the box, please write the Return Authorization Number. f. Ship the unit to the following address: Bay Technical Associates, Inc. 200 N. Second Street Bay St. Louis, MS 39520-1000, USA 188