Page 1 of Banner SM2A31RDLBQD and SM312 Mini-Beam Manual

Manual · Banner

Banner SM2A31RDLBQD and SM312 Mini-Beam Manual

Manual4 pagesPDF 571 KB

All 4 pages are below, each with its text.

Download the PDF571 KB

Names · 1 model

The models it names

Filed with · 1 model

Also filed with these models on the old site

From the manual · read page by page

Key facts from this manual

Each line names its page in the PDF.

Banner's four-page installation guide for the MINI-BEAM dc-voltage series of self-contained photoelectric sensors, such as the SM31E, SM31R, SM312LV, SM312LP, SM312D, SM312C and SM312F models. It does not name the SM2A31RDLBQD it is filed under. It shows the sensing modes, wiring, dimensions and sensor controls, then walks through mounting, alignment for each sensing mode, fiber installation and the specifications.

Device
Self-contained dc photoelectric sensors in opposed, retroreflective, diffuse, convergent, glass fiber optic and plastic fiber optic sensing modes p. 1
Supply
10 to 30V dc (10% maximum ripple) at less than 25 mA, exclusive of load p. 4
Outputs
Bipolar NPN/PNP on all models, 150 mA maximum each output at 25° C, derated to 100 mA at 70° C p. 1, 4
Response
1 millisecond, 500 Hz maximum; 0.3 millisecond on MHS-suffix models; 100 millisecond power-up delay p. 4
Repeatability
Opposed 0.14 milliseconds; retro, diffuse, convergent and fiber optic 0.3 milliseconds p. 4
Light sources
Infrared 880 nm, visible red 650 nm, visible blue 475 nm or visible green 525 nm, by model p. 1
Model suffixes
W/30 for 9 m (30') cable; QD for 4-pin Euro QD; QDP for 150 mm (6") QD pigtail; MHS for 0.3 ms response p. 1
Connections
PVC-jacketed 4-conductor 2 m (6.5') or 9 m (30') cable, or 4-pin Euro-style QD fitting; QD cables sold separately p. 4
Adjustments
Light/dark operate switch and 15-turn gain potentiometer, clutched at both ends, under a gasketed acrylic cover p. 4
Environmental rating
NEMA 1, 2, 3, 3S, 4, 4X, 6, 12 and 13; IEC IP67 p. 4
Operating temperature
-20° to +70°C (-4° to +158°F); 90% maximum relative humidity at 50°C, non-condensing p. 4
Mounting
Threaded barrel through an 18 mm hole, mounting nut supplied, or a mounting bracket p. 2, 3
Logic compatibility
NPN output drives Banner logic modules, including non-amplified MAXI-AMP and MICRO-AMP; TTL compatible p. 4
Construction
Reinforced thermoplastic polyester housing, totally encapsulated, o-ring sealing, acrylic lenses, stainless steel screws p. 4

What this manual walks you through

  • Mounting and aligning a sensor with the AID LED and gain control p. 3
  • Fixing flooding and burn-through in opposed mode p. 3
  • Dealing with background reflections in diffuse and convergent modes p. 3
  • Stopping proxing in retroreflective mode p. 3
  • Setting light operate or dark operate p. 2
  • Wiring cabled and quick-disconnect sensors p. 1
  • Installing glass fibers p. 4
  • Installing plastic fibers p. 4

Good to know

  • The guide says never to use these sensors for personnel protection. p. 4
  • Observe ESD precautions (grounding) when adjusting the gain pot or light/dark switch. p. 2
  • For diffuse sensing, the nearest background object should be at least three times the sensing distance away. p. 3
  • MHS-suffix models have reduced sensitivity range and reduced repeatability. p. 4
  • Clear plastic detection range depends on how much light the plastic transmits. p. 1

Questions this manual answers

What voltage does a Banner Mini-Beam dc sensor need?

10 to 30V dc with at most 10% ripple, drawing less than 25 mA apart from the load. p. 4

How do I align a Mini-Beam sensor?

Turn the gain to maximum, move the sensor to find the center of the zone where the red alignment LED stays on, reduce gain and repeat, then mount it solidly. p. 3

What is proxing on a retroreflective sensor and how is it fixed?

A shiny object reflects enough light back to slip through undetected; angle the beam off shiny surfaces, reduce gain, or add a polarizing filter on the SM312LV. p. 3

How do I install plastic fibers on a Mini-Beam?

Cut the fiber ends cleanly with the supplied cutter, unlock the gripper, insert the fibers fully, then slide the gripper back to lock. p. 4

The file

Size and text

Pages4
PDF571 KB
TextText from the PDF itself.

Every page · 4

Read it here

Each page as it is printed, and its words beside it, so a phone can search and copy them.

Page 1 of Banner SM2A31RDLBQD and SM312 Mini-Beam Manual

The text of page 1, from the PDF itself

MINI-BEAM® dc-Voltage Series

Installation Guide

Self-contained photoelectric sensors

Additional information on this product is immediately available online at www.bannerengineering.com/69943 View or download additional information, including excess gain curves, beam patterns and accessories. For further assistance, contact a Banner Engineering Applications Engineer at (763) 544-3164 or (888) 373-6767.

Sensing Mode

Range

Opposed Emitter Opposed Emitter - Long Range

Convergent-mode sensor

dc mb-emitter w/cable.eps

Emitters with Attached Cable bn

+

Opposed Receiver Long Range

30 m (100')

Opposed Emitter Clear Plastic Detection

0 to 300 mm (0 to 12") Actual range varies, depending on the light transmission properties of the plastic material being sensed.

Opposed Receiver Clear Plastic Detection

bu wh bk

10 mm to 3 m (0.4" to 10')

SM312LP380 mm (15")SM312DDiffuse

300 mm (12") 130 mm (5")

Convergent

SM312C2

43 mm (1.7") Focus 16 mm (0.65") Focus

49 mm (1.9") FocusGlass Fiber Opticwhwh bk

Range varies, depending on sensing mode and fiber optics used. Plastic Fiber Optic

+ 10-30V dc –bu LoadLoad

NOTES: Output Type for all models is Bipolar NPN/PNP. Load 150 mA max., each output.

SM312W SM312C

Emitters with Quick Disconnect (4-Pin Euro-Style)

bnSM312DBZInfrared 880 nm43 mm (1.7") Focus49 mm (1.9") FocusbkSM312LV16 mm (0.65") Focus16 mm (0.65") Focus

All Other Models with Quick Disconnect (4-Pin Euro-Style)

Visible Red 650 nm

Extended-Range Polarized Retroreflective

LoadbuSM31RPDSM312LVAG16 mm (0.65") Focus+ 10-30V dc –SM31EPD

50 mm to 2 m (2" to 7')

LoadbnSM31RL

Polarized Retroreflective

All Other Models with Attached Cable + 10-30V dc –

SM31EL5 m (15')Divergent DiffusebnSM31RInfrared 880 nm

Non-Polarized Retroreflective

10-30V dc –buModel* SM31E3 m (10')Opposed Receiver

Glass Fiber Optic sensor

LED

Special High-Power Option Plastic Fiber Optic

Visible Red 650 nm Visible Blue 475 nm Visible Green 525 nm

SM312CV SM312CV2 SM312CVB SM312CV2B SM312CVG SM312CV2G

Infrared 880 nmSM312FVisible Red 650 nmSM312FVVisible Blue 475 nmSM312FVBVisible Green 525 nmSM312FVGVisible Red 650 nmSM312FPVisible Blue 475 nmSM312FPBVisible Green 525 nmSM312FPGVisible Red 650 nmSM312FPH

*Standard 2 m (6.5') cable models are listed.

  • 9 m (30') cable: add suffix “W/30” (e.g., SM31EW/30).
  • 4-pin Euro QD models: add suffix “QD” (e.g., SM31EQD).
  • 150 mm (6") QD Pigtail: add suffix “QDP” (e.g., SM31EQDP). For 0.3 ms response: add suffix “MHS” (eg., SM31EMHS).

See Safety Use Warning on Back Page Printed in USA

11/04

P/N 69943 rev. B

Page 2 of Banner SM2A31RDLBQD and SM312 Mini-Beam Manual

The text of page 2, from the PDF itself

MINI-BEAM® dc-Voltage Series

Installation Guide Dimensions

Models with suffix E, EL, EPD, R, RL, RPD, LV, LVAG, LP, D, C, C2, CV, CV2, CVG, CV2G, CVB, and CV2B 3.2 mm (0.13")

Models with suffix DBZ and W

12.2 mm (0.48")

30.7 mm (1.21") 24.1 mm (0.95")

ø 3 mm Clearance (2)

ø 3 mm Clearance (2) Bezel

M18 x 1 x 15 mm Thread (Mounting Nut Supplied)

18.0 mm (0.71")

2 m (6.5') Cable Mounting Peg (ø 6.3 mm x 2.5 mm) 19.1 mm (0.75") 39.1 mm (1.54")

13.2 mm (0.52")27.4 mm (1.08")53.3 mm (2.10")

Models with suffix F, FV, FVB, and FVG

Models with suffix FP, FPB, FPG, and FPH 3.2 mm (0.13")

M18 x 1 x 19 mm Thread (Mounting Nut Supplied)

12.2 mm (0.48")

30.7 mm (1.21") 24.1 mm (0.95")

ø 3 mm Clearance (2)

Fiber Optic Fitting

2 m (6.5') Cable Fiber Optic Fitting

Mounting Peg (ø 6.3 mm x 2.5 mm)

22.3 mm (0.88")

19.1 mm (0.75")

57.5 mm (2.27") 31.2 mm (1.23")

42.1 mm (1.66")QD Models16.2 mm (0.64")

Sensor Features (shown with gasketed acrylic cover removed) Gain (Sensitivity) Adjustment Screw

Alignment Indicator Device (AID)* 12 mm Thread Quick-disconnect

20.0 mm (0.79")

Light/Dark Operate Select Switch Clockwise: Light Operate (outputs conduct when sensing light is received). Counterclockwise: Dark Operate (outputs conduct when sensing light is not received). *U.S. Patent no. 4356393

NOTE: Please observe proper ESD precautions (grounding) when adjusting gain pot or LO/DO switch.

Banner Engineering Corp. • Minneapolis, MN U.S.A.

2

P/N 69943 rev. B

www.bannerengineering.com • Tel: 763.544.3164

Page 3 of Banner SM2A31RDLBQD and SM312 Mini-Beam Manual

The text of page 3, from the PDF itself

MINI-BEAM® dc-Voltage Series

Installation Guide

Sensor Mounting and Alignment MINI-BEAM sensors perform most reliably if they are properly aligned and securely mounted. For maximum mechanical stability, final-mount MINI-BEAM sensors through 18 mm diameter holes by their threaded barrel (where available), or use a mounting bracket. A complete selection of mounting brackets is available. Visit www.bannerengineering.com/69943, or contact the factory for information on mounting options.

If the MINI-BEAM sensor is receiving its light signal, the red LED Alignment indicator will be ON and flashing at a rate proportional to the signal strength (faster = more signal). Move the sensor (or move the retro target, if applicable) up-down-right-left (including angular rotation) to find the center of the movement zone within which the LED indicator remains ON. Reducing the Gain setting will reduce the size of the movement zone, and enable more precise alignment.

Begin with line-of-sight positioning of the MINI-BEAM sensor to its emitter (opposed-mode sensing) or to its target (all other sensing modes). When using a retroreflective sensor, the target is the retroreflector (“retro target”). For diffuse or convergent sensing modes, the target is the object to be detected.

Repeat the alignment motions after each Gain reduction. When optimum alignment is achieved, mount sensor(s) (and the retro target, if applicable) solidly in that position. Increase the Gain to maximum.

Apply power to the sensor (and to the emitter, if using the opposed mode). Advance the 15-turn Gain control to maximum (clockwise end of rotation), using a small flat-blade screwdriver. The Gain control is clutched at both ends to avoid damage, and will “free-wheel” when either endpoint is reached. See Sensor Features illustration on page 2.

Test the sensor by placing the object to be detected in the sensing position, then removing it. The Alignment indicator LED should come ON when the sensing beam is established (Light condition), and go OFF when the beam is broken (Dark condition). If the Alignment indicator LED stays ON for both sensing conditions, consider the following tips for each sensing mode.

Alignment Tips Opposed-Mode Alignment

Light condition: no object in beam Dark condition: object in beam

EmitterDiffuse-Mode Alignmentctje Ob

Light condition: object in beam Dark condition: no object in beam

ctje ObReceiver

“Flooding” occurs when a portion of the sensing beam passes around the object to be sensed. “Burn-through” occurs when a portion of the emitter’s light energy passes through a thin or translucent object, and is sensed by the receiver. To correct either problem, do one or more of the following to reduce the light energy:

  • Reduce the Gain adjustment on the receiver.
  • Add an aperture to one or both lenses. (MINI-BEAM apertures, available from Banner, fit neatly inside the lens assembly.)
  • Intentionally misalign the emitter and receiver.

tro Re et rg a T

Retroreflective-Mode Alignment

If the Alignment LED does not go OFF when the object is removed from the beam, the sensor is probably detecting light reflected from some background object. To remedy this problem:

  • Reduce the reflectivity of the background by painting the surface(s) flat-black, scuffing any shiny surface, or drilling a large hole, directly opposite the diffuse sensor.
  • Move the sensor closer to the object to be detected and reduce the Gain adjustment. Rule of thumb for diffuse sensing: The distance to the nearest background object should be at least three times the sensing distance. w Lo ivity t ec und l f Re kgro c Ba

Convergent-Mode Alignment

Light condition: object in beam Dark condition: no object in beam jec

Ob

t

Light condition: no object in beam Dark condition: object in beam

A highly reflective object may reflect enough light back to a retroreflective sensor to allow that object to slip through the beam, without being detected. This problem is called “proxing,” and the following methods may be used to correct it:

  • Position the sensor and retro target so the beam will not strike a shiny surface perpendicular to the sensor lens.
  • Reduce the Gain adjustment.
  • Add a polarizing filter (for model SM312LV).

The sensing energy of a convergentmode sensor is concentrated at the specified focus point (see page 1). Convergent-mode sensors are less sensitive to background reflections, compared with diffuse-mode sensors. However, if background reflections are a problem:

  • Skew the sensor position at a 10° to 25° angle to eliminate direct reflections from shiny background surfaces.
  • Reduce the reflectivity of the background by painting the surface(s) flat-black, scuffing any shiny surface, or drilling a large hole, directly opposite the sensor.
  • Reduce the Gain adjustment.

Banner Engineering Corp. • Minneapolis, MN U.S.A. www.bannerengineering.com • Tel: 763.544.3164

P/N 69943 rev. B

3

Page 4 of Banner SM2A31RDLBQD and SM312 Mini-Beam Manual

The text of page 4, from the PDF itself

MINI-BEAM® dc-Voltage Series

Installation Guide Fiber Installation

Glass Fiber Installation

1) Install the O-ring (supplied with the fiber) on each fiber end, as shown in the drawing. 2) While pressing the fiber ends firmly into the ports on the sensor front, slide the U-shaped retaining clip (supplied with the sensor) into the slot in the sensor’s barrel, until it snaps into place.

Plastic Fiber Installation

1) With supplied fiber cutter, make a clean cut at control ends of fibers. 2) Unlock the fiber gripper as shown below. Apply appropriate fiber adaptors prior to fiber insertion, if needed. 3) Gently insert the prepared fiber ends into the ports, as far as they will go. 4) Slide the fiber gripper back to lock, as shown below.

Retaining Clip Gripper Unlock Lock

O-ring Sensor Face

Adapters for 0.25- and 0.5-mm fibers Trimmed fiber control ends

Plastic fiber receiver port Plastic fiber emitter port

Specifications Supply Voltage and Current 10 to 30V dc (10% maximum ripple) at less than 25 mA (exclusive of load) Supply Protection Circuitry Protected against reverse polarity and transient voltages Output Configuration Bipolar: One current sourcing (PNP) and one current sinking (NPN) open collector transistor Output Rating 150 mA maximum each output at 25° C, derated to 100 mA at 70° C (derate ≈ 1 mA per ° C) OFF-state leakage current: less than 1 microamp Output saturation voltage (PNP output): < 1 volt at 10 mA, < 2 volts at 150 mA Output saturation voltage (NPN output): < 200 millivolts at 10 mA, < 1 volt at 150 mA Output Protection Circuitry Protected against false pulse on power-up and continuous overload or short-circuit of outputs Output Response Time Sensors will respond to either a “light” or “dark” signal of 1 millisecond or longer duration, 500 Hz maximum. Modification for 0.3 millisecond response is available (MHS-suffix models; these models also feature reduced sensitivity range and reduced repeatability.) NOTE: Outputs are non-conducting during 100 millisecond delay on power-up. Repeatability Opposed: 0.14 milliseconds Non-Polarized and Polarized Retro, Diffuse, Convergent, Glass Fiber Optic, and Plastic Fiber Optic: 0.3 milliseconds Response time and repeatability specifications are independent of signal strength.

Adjustments Light/Dark Operate Select switch 15-turn slotted brass screw Gain (sensitivity) adjustment potentiometer (clutched at both ends of travel) Located on the rear panel, protected by a gasketed, clear acrylic cover. Indicators Patented alignment Indicator Device system (AID™, US patent #4356393) lights a rearpanel-mounted LED indicator when the sensor sees light. Its pulse rate is proportional to the light signal strength (the stronger the signal, the faster the pulse rate). Construction Reinforced thermoplastic polyester housing, totally encapsulated, o-ring sealing, acrylic lenses, stainless steel screws Environmental Rating Meets NEMA standards 1, 2, 3, 3S, 4, 4X, 6, 12, and 13; IEC IP67. Connections PVC-jacketed 4-conductor 2 m (6.5') or 9 m (30') cables, or 4-pin Euro-style QD fitting; QD cables available separately. Operating Conditions Temperature: -20° to +70°C (-4° to +158°F) Maximum relative humidity: 90% at 50°C (non-condensing) Application Note The NPN (current sinking) output of dc MINI-BEAM sensors is directly compatible as an input to Banner logic modules, including all non-amplified MAXI-AMP and MICRO-AMP modules. MINI-BEAMs are TTL compatible. Certifications

Additional information on this product is immediately available online at www.bannerengineering.com/69943 View or download additional information, including excess gain curves, beam patterns and accessories. For further assistance, contact a Banner Engineering Applications Engineer at (763) 544-3164 or (888) 373-6767.

WARNING . . . Not To Be Used for Personnel Protection Never use these products as sensing devices for personnel protection. Doing so could lead to serious injury or death. These sensors do NOT include the self-checking redundant circuitry necessary to allow their use in personnel safety applications. A sensor failure or malfunction can cause either an energized or de-energized sensor output condition. Consult your current Banner Safety Products catalog for safety products which meet OSHA, ANSI and IEC standards for personnel protection. WARRANTY: Banner Engineering Corp. warrants its products to be free from defects for one year. Banner Engineering Corp. will repair or replace, free of charge, any product of its manufacture found to be defective at the time it is returned to the factory during the warranty period. This warranty does not cover damage or liability for the improper application of Banner products. This warranty is in lieu of any other warranty either expressed or implied. P/N 69943 rev. B

Banner Engineering Corp., 9714 Tenth Ave. No., Minneapolis, MN 55441 • Phone: 763.544.3164 • www.bannerengineering.com • Email: sensors@bannerengineering.com