Browse
(440) 299-7778
Menu
(440) 299-7778
One-year parts and labor warranty30-day money-back guaranteeEnglishEspañolContact
Page 1 of Q45BB6 Series Sensors

Spec sheet · Banner

Q45BB6 Series Sensors

Spec sheet12 pagesPDF 5.8 MB

Data sheet for the Banner Q45BB6 series 10 to 30V dc photoelectric sensors, including the Q45BB6FQ5 glass fiber optic model.

Download the PDF5.8 MB

Covers · 1 model

The models it covers

Summary

What is in it

The data sheet for the Banner Q45BB6 series of one-piece 10 to 30V dc photoelectric sensors with bipolar NPN/PNP outputs. It lists every model by sensing mode (opposed, retroreflective, diffuse, convergent, glass fiber optic such as the Q45BB6FQ5, and plastic fiber optic) with range, excess gain and beam pattern, then gives specifications, dimensions, indicators and controls, hookup diagrams, quick-disconnect cables, timing logic and display modules, mounting brackets and the warranty.

From the sheet · read page by page

Key facts from this sheet

Each line names its page in the PDF.

Banner data sheet (P/N 36578 rev D) for the Q45BB6 series of 10 to 30V dc photoelectric sensors with bipolar NPN/PNP outputs, covering opposed, retroreflective, diffuse, convergent, and glass and plastic fiber-optic models. The site's Q45BB6FQ5 is the infrared glass fiber-optic model with a 4-pin Euro-style quick-disconnect. The sheet gives ranges, specifications, dimensions, wiring and accessories.

Device
One-piece photoelectric sensor (Q45BB6 series) with sinking and sourcing solid-state outputs p. 1
Sensing type
Q45BB6FQ5: glass fiber-optic model, infrared 880 nm; range depends on the sensing mode and fibers used p. 5
Connection
Q5 suffix models: 4-pin Euro-style quick-disconnect fitting; the QD cable is ordered separately p. 7, 9
Supply
10 to 30V dc (10% maximum ripple), under 50 mA excluding load; protected against reverse polarity and transients p. 7
Outputs
One PNP (sourcing) and one NPN (sinking) open-collector output, 250 mA max each up to 50°C, 150 mA at 70°C p. 7
Response time
Opposed mode 2 ms ON, 1 ms OFF; all other modes 2 ms ON/OFF; 100 ms delay at power-up p. 7
Repeatability
Opposed mode 0.25 ms; all other modes 0.5 ms p. 7
Adjustments
Light/Dark operate switch and multi-turn sensitivity control under the transparent cover p. 7, 9
Indicators
Green power LED (flashes on output overload or short), red AID signal LED pulsing with signal strength, yellow load LED p. 7
Enclosure
The data sheet states NEMA 6P and IEC IP67, and a design to withstand 1200 psi washdown p. 7
Operating conditions
-40° to +70°C (-40° to +158°F); max 90% relative humidity at 50°C, non-condensing p. 7
QD cables
4-pin straight cables MQDC-406, MQDC-415, MQDC-430, MBCC-406, MBCC-412, MBCC-430; rated 250V ac/300V dc p. 10
Plug-in modules
45LM58, 45LM58D and 45LMD add programmable output timing logic and/or a signal strength display; fit all Q45BB6 sensors p. 10
Mounting brackets
SMB30C 30 mm split clamp; SMB30MM 30 mm stainless steel bracket; SMB30SC 30 mm swivel p. 11

What this sheet walks you through

  • Choosing a model by sensing mode, from opposed to fiber optic p. 1, 2, 3, 4, 5, 6
  • Excess gain and beam patterns of the glass fiber-optic models p. 5
  • Sensor dimensions p. 8
  • Indicators and controls p. 9
  • Wiring cabled and quick-disconnect sensors p. 9
  • Quick-disconnect cables, retroreflective targets and timing or display modules p. 10
  • Mounting brackets p. 11

Good to know

  • Never use these sensors for personnel protection; they lack the self-checking redundant circuitry for safety use. p. 12
  • The output does not conduct during the 100 ms delay after power-up. p. 7
  • The glass fiber-optic models suit applications where faster sensor response is not important. p. 5
  • Quick-disconnect models need a mating cable, ordered separately. p. 7
  • Polarized sensors need corner cube retroreflective targets only. p. 10

Questions this sheet answers

What is a Banner Q45BB6FQ5?

A Q45BB6 series photoelectric sensor for glass fiber optics, infrared 880 nm, running on 10 to 30V dc with bipolar NPN/PNP outputs and a 4-pin Euro-style quick-disconnect. p. 1, 5, 7

What cable does the Q45BB6FQ5 need?

A mating 4-pin Euro-style quick-disconnect cable, ordered separately; the data sheet lists the QD cables on its page 10. p. 7, 9, 10

What is the operating temperature of the Q45BB6 sensors?

-40° to +70°C (-40° to +158°F), at up to 90% relative humidity at 50°C without condensation. p. 7

How much current can a Q45BB6 output switch?

250 mA per output up to 50°C, derated to 150 mA at 70°C. p. 7

Can the Q45BB6 be used as a safety sensor for personnel?

No. The data sheet warns never to use these sensors for personnel protection. p. 12

The whole text · 2 parts

Read the sheet here as text

Its text as extracted from the PDF, unedited, in parts; each page opens the PDF at that page.

  1. Pages 1 to 61-6
  2. Pages 7 to 127-12

The file

Revision and size

RevisionP/N 36578 rev D, 09/01
PublisherBanner Engineering Corp.
Pages12
PDF5.8 MB
TextText from the PDF itself.

The first pages · 4 of 12

Look before you download

Each page opens the PDF at that page.

Page 1
Page 1of 12
Page 2
Page 2of 12
Page 3
Page 3of 12
Page 4
Page 4of 12