Manual · Argox
Argox User's Manual
Manual33 pagesPDF 2.7 MB
User's manual for the Argox A-50, A-150 and A-200 desktop label printers: setup, ribbon and media loading, care and specifications.
Covers · 1 model
The models it covers
Summary
What is in it
A user's manual for the Argox A series desktop label printers, the A-50 (direct thermal) and the A-150 and A-200 (thermal transfer). It walks through unpacking, power, parts and features, loading ribbon and media in standard, peel-off and cutter modes, the feed button and indicators, calibration, printing a configuration report, restoring factory defaults, connecting to a computer and installing the driver, troubleshooting, cleaning and replacing the print head, and technical specifications including the PPLB printer language.
Its parts
- Checking Your Box
- Power Supply
- Parts and Features
- Loading the Ribbon
- Loading the Media
- Operator Controls
- Performing Calibration
- Printing Configuration Report
- Returning to Factory Default Settings
- Hooking up the Printer and Computer
- Communicating with the Printer
- Troubleshooting
- Caring for Your Printer
- Reference Technical Information
From the manual · read page by page
Key facts from this manual
Each line names its page in the PDF.
User's manual for the Argox A Series label printers, covering the A-50, A-150 and A-200. It walks through loading ribbon and media (standard, peel-off and cutter), calibration, the configuration report and factory reset, hooking up to a PC and installing the Windows driver, troubleshooting by the LEDs, cleaning and replacing the print head, and the technical and interface specifications.
- Interfaces
- Nine-pin RS-232 serial, Centronics parallel and USB (no USB on the A-150) p. 16
- Print speed
- A-200: 1 to 4 IPS in the driver setting p. 20
- Print modes
- Thermal transfer with ribbon or direct thermal; standard, peel-off or cutter operation p. 6, 20
- Power
- External power adapter with barrel connector; 110/220 VAC ± 10%, 50/60 Hz p. 2, 30
- Serial settings
- 2400 to 38400 baud; 8 data bits, 1 stop bit, no parity; XON/XOFF or CTS/RTS p. 32
- Serial connector
- Female DB-9 on the printer; pin 9 is reserved for a KDU p. 31
- Media
- Roll-feed, die-cut, continuous, fan-fold, tags or tickets; 1.0" to 4.25" wide; .0025" to .01" thick; up to 5" OD rolls on a 1" core p. 30
- Ribbon
- Wax, wax/resin or resin, outside coated; 2" or 4" wide; max 1.5" OD and 100 M; 0.5" notched core (no ribbon on the A-50) p. 30
- Bar codes
- Code 39, Code 93, Code 128 A/B/C, Codabar, Interleave 2 of 5, Matrix 25, UPC A/E, EAN-8/13, UCC/EAN, Postnet, German Postcode, MaxiCode, PDF417 p. 30
- Fonts
- 5 fonts, expandable 1x1 to 24x24; downloadable soft fonts; many 8-bit and 7-bit symbol sets p. 30
- Software
- PPLB printer language; Label Dr. Windows driver for Windows 98/ME/2000/XP and NT 4.0 (no USB on NT) p. 17, 19
- Darkness
- Driver darkness setting 0 to 15 p. 20
- Operating environment
- 40ºF to 100ºF (4ºC to 38ºC); 10 to 90% non condensing p. 30
- Options
- Cutter, dispenser kit, real time clock card, ArgoNet print server, ArgoKee, 2MB Asian font card p. 30
What this manual walks you through
- Checking the box and accessories p. 1
- Loading the ribbon p. 3, 4, 5
- Loading media in standard, peel-off and cutter mode p. 6, 7, 8, 9, 10, 11, 12, 13
- Calibrating the label sensor p. 14
- Printing a configuration report and returning to factory defaults p. 15
- Hooking up the printer to a computer p. 16, 17
- Installing the Windows printer and USB drivers p. 18, 19
- Setting driver parameters in each Windows version p. 20, 21, 22, 23, 24, 25
- Troubleshooting by the Power and Ready LEDs p. 26, 27
- Cleaning and replacing the thermal print head p. 28, 29
Good to know
- Run the calibration every time the media is changed, or the label sensor may misread. p. 14
- Turn the power off before connecting or disconnecting communication and power cables. p. 13
- Do not connect serial pin 9 when the host is a general host like a PC. p. 31
- Serial and parallel can work at once, but data sent on both at the same time may be damaged. p. 33
- Text and bar codes can print over 30 inches long, but graphics only a few inches with standard RAM. p. 31
Questions this manual answers
How do I reset the Argox A-200 to factory defaults?
Turn the printer on, wait 5 seconds, hold the feed button about 10 seconds until both LEDs go off and light again, then release; it feeds 12 inches and resets. p. 15
How do I print a configuration report on the Argox A-200?
Hold the feed button while turning on the power; after feeding blank media the printer prints the configuration profile. p. 15
What does a blinking power LED mean on the Argox A-200?
An error. Compare the Power and Ready LEDs with the troubleshooting tables, which cover gap detection, ribbon out or jam, label out or jam, serial errors and memory full. p. 13, 26
What serial settings does the Argox A-200 use?
2400 to 38400 baud, always 8 data bits, 1 stop bit and no parity, with XON/XOFF or CTS/RTS flow control. p. 32
Why does the A-200 print vertical streaks?
Usually a dirty or faulty print head: clean it first, and replace it if the streaks remain. p. 27