For the AMX PLB-CF2
Page 9
Operation Instructions Power-Up Procedure 1. Plug the power cord into a properly grounded 110-120VAC outlet. 2. Plug the 12 VDC power supply connector into the 12 VDC receptacle on the rear panel of the PLB-CF2. 3. The Power LED should be illuminated on the front panel. If there is a problem, contact your PHAST dealer or PHAST Technical Support. PhastLink Ports There are two PhastLink ports on the lower part of the rear panel. These are used to connect PhastLink devices to the cardframe. If more ports are required, an additional cardframe or hub box will be necessary. It does not matter which PhastLink port you use; they are all functionally identical. See the section on PhastLink Wiring for general information about connecting PhastLink devices. MCU-to-PC Connection If a PHAST MCU card is installed, a 10Base-T Ethernet port on the MCU card is used to connect the to an ethernet board in the PC. See the PHAST PLC-MCU documentation for more information on connecting and using the MCU card. Device Address A DIP switch on the rear panel allows you to set the cardframe address to match its address in the Landmark software. The following illustration shows the address settings (factory default is 0):
Figure 4
DIP Switch settings
PLB-CF2 Two-Slot Mini Cardframe
Operation Instructions
5
Page 10
Warning! Dangerous Voltage! TO AVOID SERIOUS INJURY OR DEATH, DO NOT OPEN UP THE CARDFRAME. PhastLink Cable Information This section contains information that you will need to make PhastLink cables, plus general information on connecting PhastLink devices. PhastLink cables are used to connect all PhastLink-compatible devices, including keypads, dimmers, amplifiers, audio switches, etc. PhastLink uses a standard 10Base-T connection (i.e. Category 5 wire and RJ-45 connectors). The wire should be connected in the standard manner, as shown in the following figure. If a consistent color code is used, wiring problems will be minimized. Figure 5 shows the RJ-45 Socket and Connector, and Figure 6 gives pinout information.
Figure 5
RJ-45 Socket
RJ-45 Plug
RJ-45 Socket and Connector 1 2 3 4 5 6 7 8
1 2 3 4 5 6 7 8
6
Operation Instructions
PLB-CF2 Two-Slot Mini Cardframe
Page 11
Figure 6
RJ-45 Pinout Information
RJ-45 Pinout Information
Pin #
Wire Color
Polarity
Function
1
White/Green
+
Transmit
2
Green
–
Transmit
3
White/Orange
–
Mic
4
Blue
–
Ground
5
White/Blue
+
12VDC
6
Orange
+
Mic
7
White/Brown
+
Receive
8
Brown
–
Receive
PhastLink uses a standard 10Base-T connection (i.e. Category 5 wire and RJ-45 connectors). The wire should be connected in the standard manner, as shown in the following figure. If a consistent color code is used, wiring problems will be minimized. It is important that the correct pairing is observed. Transmit, Receive, and Mic need to be on twisted pairs. Splitting pairs (e.g., using a white/green wire with a blue/white wire for transmit) will result in increased crosstalk, and may result in bus failure or noise on the intercom. Connecting to a Cardframe or Hub If a PLB-CF10 cardframe is used, a 15-port hub is built into the cardframe. The maximum length of wire per port is 1,000 feet. Each PhastLink device has two RJ45 connectors to allow multiple devices to be daisy-chained on one PhastLink port. Refer to the PLB-CF10 documentation for more detailed connection information. The limit for each home run is 10 PhastLink devices. Extra hubs can be added to provide additional ports.
PLB-CF2 Two-Slot Mini Cardframe
Operation Instructions
7
Page 12
Figure 7
Connecting to a PLB-CLF cardframe.
Note
Only one PHAST keypad can be used per port, so homerun each keypad.
For optimum performance, PHAST recommends the installation of a double 120ohm terminator in one of the RJ-45 jacks of the last device (or the only device) in a chain of PhastLink devices. Building a double 120-ohm terminator: 1. Install a 120-ohm resistor (1/4-watt or larger) between pins 1 and 2 of an RJ-45 connector. 2. Install a 120-ohm resistor (1/4-watt or larger) between pins 7 and 8 of the same
RJ-45 connector. PHAST LCD keypads must connect directly to a PHAST Hub (or PHAST Microphone Hub). Due to power requirements and/or the need for a separate microphone line for each keypad, they cannot be daisy-chained to other LCD keypads; they can, however be daisy chained with other PhastLink devices.
8
Operation Instructions
PLB-CF2 Two-Slot Mini Cardframe
Page 13
When connecting PHAST keypads that will be used as intercoms, the Microphone Hub taps off the intercom audio signal carried on the PhastLink cable from that keypad. PhastLink devices cannot be wired in a star configuration.
PLB-CF2 Two-Slot Mini Cardframe
Operation Instructions
9
Page 14
10
Operation Instructions
PLB-CF2 Two-Slot Mini Cardframe
Page 15
Troubleshooting •
Power LED – If the power LED is not on, check the power cord and power switch (PLB-CF10) or check the external power supply (PLB-CF2).
•
Diag LED – This LED indicates the state of all cards in the PLB-CF2 or PLB-CF10. The Diag light will flash on briefly when a card is first plugged in or powered up. If a card causes an error, the Diag LED will either flash on and off continually or it will remain on continually. Remove the cards one by one until you locate the faulty card.
•
Data LED – This LED is a 'window' into the network, flashing on briefly whenever a packet is sent over the network by the MCU card or by any device on the PhastLink network. In normal operation, the Data LED should be off for a larger percentage of time than it is on. If the Data LED is on continually, there may be a problem with a hub-tohub connection (e.g., Hub In connected to Hub In, or a bad cable). A looped cable connecting two PhastLink ports or a faulty cable can also cause the Data LED to remain on continually. Remove each cable one by one, then each card one by one until the faulty cable or card is located. If all PhastLink cables, hub-to-hub cables, and cards are removed and the Data LED remains on, the PLB-CF2 or PLB-CF10 may be at fault – contact PHAST Tech Support. If the Data LED is not on continually but is on for a larger percentage of time than it is off, it may indicate a faulty device or card, and the condition may slow down network response.
•
PLB-CF2 Two-Slot Mini Cardframe
Link LED – The Link LED on each card indicates when it sends a message over the network. If a card's Link LED is on continually, that card may be causing the problem. For example, this could be caused by a contact card with an intermittent short or by a faulty contact sensor. If no cards are at fault, unplug each PhastLink cable run until the suspect cable is located.
Troubleshooting
11
Page 16
brussels • dallas • los angeles • mexico city • philadelphia • shanghai • singapore • tampa • toronto • york 3000 research drive, richardson, TX 75082 USA • 469.624.8000 • 800.222.0193 • fax 469.624.7153 • technical support 800.932.6993
051-004-2415 8/01 ©2001 AMX Corporation. All rights reserved. AMX, the AMX logo, the building icon, the home icon, and the light bulb icon are all trademarks of AMX Corporation. AMX reserves the right to alter specifications without notice at any time. *In Canada doing business as Panja Inc.