Page 28

The Auth setting determines what type of network system you are using.

These two modes simply define how the above key sets will be used to encrypt the data sent over the radio. Whichever mode is selected, the access point MUST be set to the same mode for communications to take place.

The Power Save setting will force the radio card to turn off when not in use to save power. If you experience connection problems, turn the Power Save feature off. Battery life will be shortened with the Power Save feature shutoff. The Channel setting determines which channel the radio card will start to communicate on. This should be set to the same channel as the access points.

25

Page 29

Host Server List The Connection Settings determine how the M7170 vehicle mount terminal will communicate to a host server over the network. When the M7170 vehicle mount terminal first powers up, it tries to establish a connection to an RF or standard network. If this is successful, it will then start a Telnet session using the settings described in this section.

During this start-up process, the M7170 will look to see if multiple host servers have been defined in the Host Server List. If only one server is defined, the M7170 will proceed to attempt to establish a connection with that server. However, if more than one host server has been defined, the user will be prompted to choose a host server name from a list of servers. If multiple host have been defined, and a user wishes to select a different host, then the user would hit the Menu key then Reconnect and the host list will be re-displayed. The user should then simply select the host they wish to connect to.

When defining hosts servers, names can be any combination of letters and numbers, up to 15 characters long. The Port setting determines which network port the M7170 vehicle mount terminal will try to connect to. The default setting is Port 23 but some network systems require this to be changed. If the AML CommandLink™ RF software is being used with your network, then the IP address of the CommandLink™ RF server must be supplied. This is the IP address of the computer where the CommandLink™ Communicator is running.

26

Page 30

The M7170 vehicle mount terminal has optional Terminal Emulation software available that enables it to communicate directly with most host systems including IBM mainframe and IBM AS400 systems. This software has many more features than described in this manual.

Terminal Options The Term setting determines what terminal type the M7170 will emulate. The default setting is “amlterm” which is a superset of VT100 Terminal Emulation. If you are using CommandLink™ software, set the Terminal type to amlterm. When using amlterm with CommandLink™, the optional features are controlled by the CommandLink™ server.

The Local Echo feature enables or disables displaying of characters sent to the host system. The default setting for most host systems is Local Echo disabled (unchecked).

The “amlterm” emulation is designed to be used with the AML CommandLink™ software. Using this emulation with host servers designed for other types of emulation, will produce unexpected results. The “vt100” and “vt220” terminal emulations are a standard type of emulation typically used with UNIX based host servers. The “custom” selection allows the user to modify the “vt100” emulation for custom applications. This emulation is rarely used. The M7170 supports other types of terminal emulations using optional software. 27

Page 31

If a different terminal type is selected, then the optional features for that emulation are displayed. These features allow you to customize how the M7170 vehicle mount terminal will display the information from your host server.

The Font function allows you to select a custom font size which will change the amount of information displayed on the screen.

If the Disable Scrolling check box is checked the screens will lock into the upper left hand corner of the display regardless of how much information is sent to the screen. This box is unchecked by default.

28

Page 32

If the Virtual 24x80 check box is unchecked all the text sent to the terminal will be squeezed into the current display size (which depends on the font size selected). Most terminal emulation screens are written for a 24 column by 80 character display size so this box is checked by default.

If the Follow Cursor check box is checked then the screen will scroll to wherever the cursor is on the display. This box is unchecked by default.

The Col Shift function determines how many columns the display will move each time the Shift <arrow> keys are used. This allows the operator to “pan around” the currently displayed screen. Use the left 3and 4right arrow keys to change this setting.

29

Page 33

The Row Shift function determines how many rows the display will move each time the Shift <arrow> keys are used. This allows the operator to “pan around” the currently displayed screen. Use the left 3and 4right arrow keys to change this setting.

Save Settings The <Save Settings> function allows the new network settings to be permanently stored in the M7170 vehicle mount terminal’s non-volatile memory.

If you do not save your settings they will be lost when you exit the Network Settings screen. The terminal options will only be made permanent if you do a Save Settings, otherwise they are lost when the unit is turned off and on.

30

Page 34

Diagnostic Menu The “Diagnostic Menu” has several powerful functions that can help pinpoint a variety of network problems. The Diagnostic menu can be used to determine connectivity to the network as well as connectivity to the server or host computer.

RF Signal Strength If the optional RF card is installed, the “RF Signal Strength” function allows the operator to test the RF Link Status.

The “RF Quality” bar graph shows the RF signal strength of the closest Access Point. If this bar graph is at 0% then there is no active Access Point in the area or your network settings are wrong. Obviously the M7170 vehicle mount terminal can not function without a good quality signal from an Access Point. The “Avg. Signal” bar graph indicates how much of the RF signal being received is usable. As this percentage lowers, so will the TX Rate. The “Avg. Noise” bar graph indicates how much of the RF signal is un-unusable. If the RF signal is too low or the RF noise is too high, the M7170 vehicle mount terminal will perform much more slowly or not at all.

31

Page 35

The “WLAN:” shows the current connection status reported by the internal RF card. This status can be a very useful tool to determine if an RF connection is being made. The description of this status is shown below: Disabled

This normally means that either network settings are being changed or the RF card is malfunctioning or not making contact.

Searching

This can appear in these types of situations: 1. No access point at all. 2. There is no RF coverage in this area. 3. The SSID is set wrong. 4. The WEP is wrong and the authorization is set to SharedKey.

Connected - Ad Hoc

This is when the M7170 is connected to one and only one RF card in a peer-to-peer mode (like a laptop PC RF card).

Connected - AP

Normally this means everything is OK and the user should be able to communicate. It is possible that the WEP settings are wrong but the authorization is set to OpenSystem.

Out of Range

This means that there was a functioning connection and the unit has gone out of range.

The “MAC: 00:40:05:DF:88:64” is the hardware address of the currently connected Access Point. This address is unique to each Access Point used. In Ad-Hoc mode this will display “N/A – Ad Hoc Mode”. The “TX Rate” shows the speed in Mega-Bits per Second (Mbps) that the unit is currently transferring data. The transfer speed will start at 11 Mbps and “fall-back” to lower speeds depending on the RF strength and quality. This “fall-back” is automatic and can not be set by the operator. If you find this speed to be unacceptably low, you must improve the wireless RF network coverage in your area.

The “RF Strength” function can be used to test the RF coverage of a wireless RF local area network.

32

Page 36

Ping Server The “Ping Server” function is a very powerful tool to test connectivity through the wireless RF network.

When the “Ping Server” function is selected, the dialog box includes a section to type an IP address on the bottom. Once a valid IP address is typed hit [ENTER] to start the “pinging” process. Press the [ESC] key when finished.

The “Ping Status” screen will show the M7170 vehicle mount terminal trying to contact the listed IP Address. Once the connection is made the M7170 vehicle mount terminal will continuously send packets of data to time the connection speed in milliseconds (ms). The “Ping Status” screen will display the results of the ping process.