Page 55

CLONING SETUP INFORMATION When multiple readers are to be setup in the same configuration, it is advantageous to setup the first reader, and clone (copy) that setup to all the other units. The setup information can be (1), stored on a computer for cloning from computer to reader, or (2), cloned directly from one reader to another. These methods are described below:

CLONING FROM COMPUTER TO READER BEFORE YOU START, HAVE THE FOLLOWING EQUIPMENT READY: -

-

A PC CLONE CABLE (with a 9 pin plug (male) and a 25 pin socket (female)). A communication software package must be installed on your computer, and it must have the following configuration settings: BAUD RATE: must match the reader's setting DATA BITS: 8 bits The configured reader, which is to send the clone information, must have the following configuration setting: DATA BITS: 8 bits (the default setting) NOTE: If the clone information has already been sent to your computer, start at step 10.

Step 1:

Start with the configured reader (denoted as the "SOURCE" reader) connected to the computer's serial port..

Step 2:

Plug the 9 pin end of the PC CLONE CABLE into the SOURCE reader's connector labeled "HOST", located on the rear panel of the reader.

Step 3:

Scan the START bar code on the READER SETUP MENU.

Step 4:

Plug the other end of the PC CLONE CABLE (the 25 pin female) into the computer's RS-232 serial port.

Step 5:

At the computer, run your communications program and put it into RECEIVE mode.

51

Page 56

Step 6:

Scan the following "CLONE" bar code:

CLONE Step 7:

Once the clone information has been transmitted, take any steps required to save the information on the computer.

Step 8:

From the SOURCE reader, scan EXIT (saving OR ignoring changes) on the READER SETUP MENU.

Step 9:

Disconnect the SOURCE reader from all cables leading to the computer.

Step 10:

Plug the 9 pin end of the PC CLONE CABLE into the reader which is to receive the clone information (denoted as the "TARGET" reader). The TARGET reader's connector, located on the rear panel, is labeled "HOST".

Step 11:

At the computer, run the communications program. Note that the communications BAUD RATE must be set to match the TARGET reader's BAUD RATE (the default setting is 9600).

Step 12:

Set the communications program to TRANSMIT. The reader will beep twice, pause, and beep three times more, indicating the following: 2 beeps: indicate the clone information was received 3 beeps: indicate the reader is now configured

Step 13:

Now you are ready to disconnect the newly configured reader from all cables leading to the computer.

Step 14:

Repeat steps 10 -14 for each additional reader to be cloned.

52

Page 57

CLONING FROM READER TO READER BEFORE YOU START, HAVE THE FOLLOWING EQUIPMENT READY: -

A READER CLONE CABLE (with two 9 pin male plugs). The two readers. The reader which is to receive the clone information must have the following configuration settings: BAUD RATE: must match the configured reader's setting DATA BITS: 8 bits (the default setting)

Step 1:

Plug one end of the READER CLONE CABLE into the configured reader (denoted as the "SOURCE" reader). The SOURCE's connector, located on the rear panel of the reader, is labeled "HOST".

Step 2:

Plug the other end of the READER CLONE CABLE into the reader which is to receive the clone information; this reader is denoted as the "TARGET". The TARGET's connector, located on the rear panel of the reader, is also labeled "HOST".

Step 3:

From the "SOURCE" reader, scan the START bar code on the READER SETUP MENU.

Step 4:

Still at the "SOURCE" reader, scan the following "CLONE" bar code:

CLONE Step 5:

The "TARGET" reader will beep twice, pause, and beep three times more, indicating it has received the clone information and is now configured.

Step 6:

Disconnect the CLONE CABLE from the newly configured TARGET reader.

Step 7:

For each additional reader to be cloned, connect a TARGET reader to the source reader and repeat steps 2 through 6.

Step 8:

When cloning is complete, go to the SOURCE reader and scan EXIT (saving OR ignoring changes) on the READER SETUP MENU.

Step 9:

Next, disconnect the CLONE CABLE from the SOURCE reader.

53

Page 58

SPECIFICATIONS BAR CODES SUPPORTED Auto-discriminates between all of the following codes: • Code 3 of 9 (Code 39) • Extended Code 3 of 9 (Full ASCII) • Interleaved 2 of 5 (Variable and Fixed Length, Check Digit) • UPC-A (Including 2 and 5 Character Supplements) • UPC-E(0), UPC-E(1) • EAN/JAN (Including 2 and 5 Character Supplements)

• • • • •

Codabar Code 128 Code 93 Code 11 MSI/Plessey

INPUT DEVICES SUPPORTED Lasers (Helium-Neon, Visible Laser Diode, Infrared) CCD Scanners Wands (Visible and Infrared) Slot Readers (Or Badge Readers) Magnetic Stripe Readers (Single or Dual Track) USER PROGRAMMABLE FEATURES All features are easily programmed with a bar code menu: Bar Code Selection: Preambles/Postambles: Laser Configuration: • Enable/Disable • Bar Code (15 Chars Max) • Laser Time-Out • Length • Mag Stripe (15 Chars Max) • Trigger Function • Check Digit • Transmit Delay • Continuous Mode • Start/Stop Transmit Beep Tone and Length Mag Stripe Data Format Inter-Character Delay RS-232 SERIAL PORT Baud Rates: 150, 300, 600, 1200, 2400, 4800, 9600, 19.2K, 38.4K Parity: NONE, ODD, EVEN, MARK Data Bits: 7 or 8 Signals: Transmit Data, Receive Data, Signal Ground, DTR, RTS, CTS, DSR, DCD INDICATORS Audio "BEEP" Indicates Successful Read A Red/Green LED Indicates Status of Reader POWER REQUIREMENTS Power Consumption = 0.5 Watts. (12V Laser Requires 12V Regulated Supply) CONNECTORS Laser Input: 9 Pin "D" Style Wand Input: 5 Pin DIN Style Mag Stripe Input: 8 Pin DIN Style RS-232 Interface: 25 Pin "D" Style External Power Input: 2.5 mm Barrel Connector

ENVIRONMENTAL Operating Temperature: 0o to +50 o C Storage Temperature: -30o to +70 o C Relative Humidity: 5% to 95% (Non-Condensing)

PHYSICAL SPECIFICATIONS Weight: 14 oz Width: 5 1/8 in Length: 5 1/4 oz Height: 1 1/2 in

54

Page 59

SIGNAL DEFINITIONS WAND/MAG STRIPE INTERFACE PIN SIGNAL 1 +5V 2 DATA (____ DATA - MAG STRIPE) 3 GROUND _____ 4 CLOCK (MAG STRIPE) ___________ 5 CARD PRESENT (MAG STRIPE)

5

1

4

2 3

DUAL MAG STRIPE INTERFACE PIN SIGNAL 1 +5V ____ TRACK 2 2 DATA, _____ 3 CLOCK, TRACK 2 4 GROUND ____ 5 DATA, TRACK 1 _____ 6 CLOCK, TRACK 1 ___________ 7 CARD PRESENT 8 GROUND

8

7

1

6

2 5

LASER INTERFACE PIN SIGNAL 1 SYNC 2 DATA 3 DECODE LED 4 NO CONNECTION 5 TRIGGER 6 HEAD ENABLE 7 GROUND 8 SHIELD GROUND 9 LASER POWER

1

RS-232C HOST /TERMINAL INTERFACE PIN SIGNAL 1 FRAME GROUND 2 *TRANSMIT DATA 3 *RECEIVE DATA 4 REQUEST TO SEND 5 CLEAR TO SEND 6 DATA SET READY 7 SIGNAL GROUND 8 DATA CARRIER DETECT 9 (20) DATA TERMINAL READY (pin 20 on the 25 pin cable assemblies)

3

4 2

3

4

5

6

7

8

9

5

4

3

2

9

8

7

1

6

* Pin 2 from HOST is connected to Pin 3 of TERMINAL while Pin 3 of HOST is connected to Pin 2 of TERMINAL. EXTERNAL POWER SUPPLY INTERFACE CONNECTOR: FEMALE BARREL 2.5mm x 5.5mm (9 - 12 VDC, center positive)

-

+ 55

Page 60

APPENDIX A - FUNCTION & SPECIAL KEYS

With FUNCTION KEYS enabled, the decoder can accept a given ASCII character and transmit a corresponding FUNCTION KEY to the computer. The ASCII characters and values are listed in the table below. ASCII CHARACTERS

FUNCTION KEYS

ASCII VALUES

DC1

F1

17

DC2

F2

18

DC3

F3

19

F4

20

DC4 NAK

F5

21

SYN

F6

22

26

ETB

F7

23

CAN

F8

24

EM

F9

25

SUB

F10

26

SPECIAL KEYS

With SPECIAL KEYS enabled, the decoder can accept a given ASCII character and transmit a corresponding SPECIAL KEY to the computer. The ASCII characters and values are listed in the table below. ASCII CHARACTERS

SPECIAL KEYS

ASCII VALUES

SOH

(Left Arrow)

1

STX

(Right Arrow)

2

ETX

(Up Arrow)

3

EOT

(Down Arrow)

4

ENQ

HOME

5

ACK

END

6

BEL

DELETE

7

VT

PAGE UP

11

FF

PAGE DOWN

12

SO

SHIFT ON

14

SI

SHIFT OFF

15

DLE

INS

16

FS

CTRL ON

28

GS

CTRL OFF

29

RS

ALT ON

30

US

ALT OFF

31

A-1

Page 61

APPENDIX B - EXTERNAL POWER SUPPLY REQUIREMENTS The MODEL 2500 can support both 12V and 5V LASERS (and CCD scanners). The power source for the "LASER" connector on the front panel of the reader is determined by a jumper located inside the enclosure.

When the jumper is set to the 12V or EXTERNAL position, 12V power is taken directly from the external power supply. In this configuration an external 12V regulated power supply MUST be connected to the reader. When the jumper is set to the 5V or INTERNAL position, 5V power is supplied to the laser interface. The following table lists various configuration requirements:

INPUT DEVICE LASER LASER CCD

POWER REQUIREMENT 12V 5V 5V

JUMPER POSITION EXTERNAL INTERNAL INTERNAL

NOTE: The reader is shipped from the factory with the jumper set to the INTERNAL position. This will supply 5V to the laser.

B-1

Page 62

APPENDIX C - CODE 39 SPECIFICATIONS Code 39 is a variable length alphanumeric code. Each character is made up of nine elements, five bars and four spaces. Three of the elements are wide and six are narrow. Code 39 is a popular choice for applications because: - it is easy to print with low cost dot matrix printers large character set (A-Z, 0-9, 7 special characters) code can be extended to include the entire 128 ASCII character set variable length

0123456789

ABCDE12345

CHARACTERISTICS: Character Set: 26 uppercase letters (A - Z) 10 digits (0 - 9) 7 special characters (SPACE -.$/+%) Symbol Length: Variable Check Digit: Optional Bi-directional Decoding: Yes Maximum Density: 9.8 char./inch (using .0075 inch narrow element)

C-1

Page 63

CODE 39 CHARACTER SET:

An optional check character can be used for applications requiring higher levels of data security. When used, the check character immediately follows the last data character. The check digit is calculated as follows: 1.

Each data character is assigned a numerical value as shown in the following table: CHAR

VALUE

CHAR

VALUE

CHAR

VALUE

0 1 2 3 4 5 6 7 8 9 A B C D E

0 1 2 3 4 5 6 7 8 9 10 11 12 13 14

F G H I J K L M N O P Q R S T

15 16 17 18 19 20 21 22 23 24 25 26 27 28 29

U V W X Y Z . SPACE $ / + %

30 31 32 33 34 35 36 37 38 39 40 41 42

C-2