Browse
(440) 299-7778
Menu
(440) 299-7778
One-year parts and labor warranty30-day money-back guaranteeEnglishEspañolContact

The text of a manual · part 2 of 9

Bar Code and Magnetic Stripe Reader Model 2500 User's Manual, pages 10 to 18

Pages 10 to 18 of 81

The original document is the PDF (657 KB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.

For the AML M2500

Page 10

Step 8:

Verify that the cables are connected as shown below:

ORIGINAL SYSTEM CABLE

"TERMINAL" CABLE ASSEMBLY

"HOST" CABLE ASSEMBLY

WAND

BAR CODE READER ELECTRONICS UNIT

"HOST" PORT

"TERMINAL" PORT

6

HOST COMPUTER SYSTEM

POWER SUPPLY

Page 11

Step 9:

With the power supply connected, the "POWER" display on the front panel of the reader will display RED and the reader will BEEP twice. Approximately 1/2 second later the display will change to GREEN.

Step 10:

If the reader has been installed correctly, you should be able to type on the terminal's keyboard and communicate with the host computer system.

Step 11:

The bar code reader is now operational and ready to use. The terminal is fully functional and you may enter data via the keyboard like you did prior to installation. To enter bar code data, simply scan the bar code and the data will be transmitted to the host system just like it was typed in from the terminal's keyboard.

Step 12:

The reader is shipped from the factory with the serial port parameters set to the following defaults: BAUD RATE: DATA BITS: PARITY: OUTPUT DATA: DUPLEX MODE:

9600 8 NONE ASCII FULL

NOTE: The reader's serial port parameters must be set to match the terminal. Check your terminal's serial port parameters against those listed above. If any parameters are different, the reader must be set to match the terminal. Proceed to the section of the manual entitled CHANGING THE DEFAULT SETTINGS.

7

Page 12

CONNECTING THE MODEL 2500 TO THE PC'S SERIAL PORT The Model 2500 can be connected to the PC's serial port and used as a standard RS-232 serial scanner. Step 1:

The bar code reader comes with two cable assemblies: TERMINAL CABLE ASSEMBLY:

9 pin plug (male) to 25 pin plug (male)

HOST CABLE ASSEMBLY:

9 pin plug (male) to 25 pin socket (female)

To connect the bar code reader to the PC's serial port, only the HOST CABLE ASSEMBLY will be used. Plug the 9 pin end of the HOST CABLE ASSEMBLY into the connector labeled "TERMINAL" located on the rear panel of the bar code reader. Step 2:

Plug the other end of the HOST CABLE ASSEMBLY (the 25 pin female) into the PC's serial port (either COM1 or COM2).

Step 3:

Set the bar code reader to HALF DUPLEX MODE. (See the Programming Guide section of the USER'S MANUAL).

Step 4:

The SOFTCOM utility program is included with the Model 2500 which enables RS-232 serial data to appear as keyboard data to the PC. To install SOFTCOM on your PC, you must perform the following steps: - Insert the SOFTCOM diskette into drive A on the PC. - At the DOS prompt (C:>), type A: and press ENTER. - At the A:> prompt, type INSTALL and press ENTER.

Step 5:

Run the configuration program SCONFIG and set the serial port parameters to match those of the bar code reader.

Step 6:

Run the program SOFTCOM. With SOFTCOM loaded, any data scanned with the bar code reader will appear as keyboard data to your program.

8

Page 13

DAISY CHAIN INSTRUCTIONS Daisy Chaining UsingSOFTCOM Keyboard Emulation Software to Poll M2500's 1. 2.

Set SOFTCOM keyboard emulation software for daisy chaining. Program each M2500 decoder with a unique daisy chain ID.

Daisy Chaining Using SOFTCOM Keyboard Emulation Software and a Master M2500 to Poll the Other M2500's in the Daisy Chain 1. 2.

Do not set SOFTCOM for daisy chaining. Program the 1st M2500 (MASTER) to be the daisy chain Master Controller.

3.

Program each daisy chained M2500 decoder with a unique daisy chain ID.

NOTE: The MASTER M2500 cannot be used for data entry. Daisy Chaining Using an M2000/M2002 to Poll the M2500's in the Daisy Chain 1. 2.

Program the M2000/M2002 to be the Daisy Chain Master Controller. Program each M2500 decoder with a unique daisy chain ID. NOTE: Under most circumstances the M2000/M2002 should have the serial port programmed for 'PASS THROUGH' mode.

Daisy Chaining Using Your Own Polling Software 1. Each transmitted ID must be followed with a CARRIAGE RETURN <CR>. 2. If the decoder that is being polled has any data, it begins transmitting data within 2 characters time at the current baud rate. EXAMPLE:

Using 9600,N,8,1 as the Serial Port Parameters. The decoder has an ID of '1', so the polling software sends a '1' + <CR> and waits for at least (104 * 11 *2)= 2288 microseconds for the decoder box to start sending data. If the decoder box does not start sending data, then start the polling sequence for the next decoder. If data is received, allow a delay of 50 milliseconds following the last data character before polling again.

9

Page 14

DAISY CHAIN CONNECTION DIAGRAMS PC-M2500 Daisy Chain Using Softcom Communications Software as the Controller

PC-M2500 Controller-M2500-M2500 Using M2500 Controller & Softcom Communication Software

PC-M2000 Controller-M2500-M2500

10

Page 15

SCANNING BAR CODES WAND SCANNING Step 1:

HOLD THE WAND LIKE A PENCIL, tilted at an angle of 10 to 30 degrees from vertical.

Step 2:

TOUCH the wand tip to the WHITE SPACE before the label.

Step 3:

Move the wand QUICKLY across the label as if you were drawing a straight line through the middle of it.

Step 4:

Begin and end your stroke in the WHITE SPACE. Maintain a smooth, even stroke while scanning. You can read labels bidirectionally (either left-to-right or right-to-left) and the data will output correctly to your computer.

Step 5:

If you scanned the label correctly, you will hear a short BEEP. When the "POWER" light turns GREEN the reader is ready to scan another label.

11

Page 16

LASER SCANNING **CAUTION** ALTHOUGH THE LIGHT EMITTED FROM CLASS II AND CLASS IIA LASERS IS NOT CONSIDERED HAZARDOUS, AVOID STARING DIRECTLY INTO THE LIGHT BEAM. EXTENDED EXPOSURE MAY CAUSE DAMAGE TO YOUR EYES.

Step 1:

AIM the LASER at a bar code label. Hold the LASER approximately 3 to 6 inches from the label. NOTE: The maximum scanning distance depends on the label density. Typical scanning distances vary from 3 to 18 inches.

12

Page 17

Step 2:

SQUEEZE the TRIGGER on the laser. The front panel "POWER" light on the reader will change to RED and the "SCAN" light on the back of the laser will turn on. Simultaneously the laser will emit a thin red beam of light. The beam must cover the entire bar code label and part of the white area on both sides.

RIGHT 123456

WRONG 123456

Step 3:

After a successful read the following will occur: -

The reader will BEEP. The "DECODE" light on the back of the laser will turn on. The reader will turn off the red beam of light. The bar code data is transmitted to the computer.

NOTE:

Step 4:

If the laser has not read the label within approximately one second, it will turn off the beam. Try moving the laser closer to the bar code label and adjusting the pointing angle.

When the front panel "POWER" light changes to GREEN, the reader is ready to scan another label.

13

Page 18

INSTALLING AND USING THE MS941 TRIGGERLESS LASER

INSTALLATION After installing the decoder box according to the instructions in the general "Installation Instructions" section, you are ready to connect the laser. Step 1:

Plug the end of the laser's cable into the square connector labeled "LASER" located on the front panel of the reader. See the diagram below: MICROSCANNER

AMERICAN MICROSYSTEMS

LASER

Step 2:

WAND

MSR

POWER

For "hands-free" scanning, note the following: The cradle can be removed from the stand and set on a horizontal surface (on its rubber feet), or mounted directly to a horizontal or vertical surface. The cradle has magnets which hold the LASER in place. VERTICAL COUNTER MOUNT

VERTICAL WALL MOUNT

HANDS-FREE SCANNING STAND

HAND-HELD

HORIZONTAL COUNTER MOUNT

HANDS-FREE

14