Browse
(440) 299-7778
Menu
(440) 299-7778
One-year parts and labor warranty30-day money-back guaranteeEnglishEspañolContact

The text of a manual · part 3 of 6

Fast Ethernet Switch AT-FS716L, AT-FS724L Installation Guide: Chapter 1

Pages 10 to 21 of 41, from Fast Ethernet Switch AT-FS716L, AT-FS724L Installation Guide

The original document is the PDF (873 KB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.

Filed in the catalog under the Allied Telesis AT-FS716

Page 10

The text of this page cannot be shown here; see it in the PDF.

Page 11

AT-FS716L & AT-FS724L Fast Ethernet Switch Installation Guide

Overview The AT-FS716L and AT-FS724L Fast Ethernet Switches provide simple, energy efficient, and cost-effective solutions for switching 10 Mbps and 100 Mbps network traffic. The AT-FS716L and AT-FS724L switches feature 16 and 24 10/100Base-TX twisted-pair ports respectively. Each port has an RJ-45 connector and a maximum operating distance of 100m and is capable of Auto-Negotiating speeds of 10 or 100 Mbps at half/full-duplex operation. Both the AT-FS716L and AT-FS724L Fast Ethernet switches can be used on a desktop, mounted to a wall or in a rack and feature high efficiency, low power consumption internal power supplies. These switches are easy to install and do not require any software configuration or management. Figure 1 and 2 illustrate the front and rear panels of these switches.

AT-FS724L

100 LINK

24 Port Unmanaged Fast Ethernet Switch

POWER

1

3

5

7

9

11

13

15

17

19

21

23

2

4

6

8

10

12

14

16

18

20

22

24

ACT

10 LINK

FDX

ACT

HDX

COL

1

3

5

7

9

11

13

15

17

19

21

23

2

4

6

8

10

12

14

16

18

20

22

24

1540

100-240VAC~

1541

Figure 1. AT-FS724L Front and Rear Panels

AT-FS716L

100 LINK

16 Port Unmanaged Fast Ethernet Switch

POWER

1

3

5

7

9

11

13

15

2

4

6

8

10

12

14

16

ACT

10 LINK

FDX

ACT

HDX

COL

1

3

5

7

9

11

13

15

2

4

6

8

10

12

14

16

1527

100-240VAC~

Figure 2. AT-FS716L Front and Rear Panels 11

Page 12

The text of this page cannot be shown here; see it in the PDF.

Page 13

The text of this page cannot be shown here; see it in the PDF.

Page 14

Chapter 1: Product Description

LED ecoFriendly Push Button The LED ecoFriendly push button is located next to the Power LED on the left-hand side of the front panel as illustrated in Figure 3. It enables the LED Low Power Mode (LPM) feature. This mode allows you to conserve power by turning off the port status LEDs when you do not required the LED status indications on the front panel. To toggle the LEDs on or off, press the ecoFriendly button. The LPM feature does not affect the the Power LED or the network operations of the switch ports.

POW

Figure 3. LED ecoFriendly Push Button

Twisted-Pair Ports

Type of Connector The twisted-pair ports feature 8-pin RJ-45 connectors. (For the port pinouts, refer to “RJ-45 Twisted-Pair Port Connectors” on page 40.

Speed The ports are 10Base-T and 100Base-T compliant and are capable of 10 megabits per second (Mbps) and 100 Mbps speeds. The ports are IEEE 802.3u Auto-Negotiation compliant. With Auto-Negotiation, the switch automatically matches the highest possible common speed between each switch port and each end-node. For example, if an endnode is capable of only 10 Mbps, the switch sets the port connected to the end-node to 10 Mbps.

Duplex Mode Each twisted-pair port on these switches can operate in either half- or full duplex mode. The twisted-pair ports are IEEE 802.3u-compliant and will Auto-Negotiate the duplex mode setting. Note In order for the switch to set the duplex mode for each port correctly, the end-nodes that you connect to the switch ports should also use Auto-Negotiation. Otherwise, a duplex mode mismatch can occur, affecting network performance. For further information, refer to “Duplex Mode” on page 18.

14

Page 15

AT-FS716L & AT-FS724L Fast Ethernet Switch Installation Guide

Maximum Distance Each twisted-pair port has a maximum operating distance of 100 m (328 feet).

Type of Cabling For 10 Mbps operation, Category 3 or better 100 ohm shielded or unshielded twisted-pair cabling is required. For 100 Mbps operation, Category 5 and Enhanced Category 5 (5E) 100 ohm shielded or unshielded twisted-pair cabling is required.

Auto MDI/MDI-X All of the twisted-pair ports on these switches are auto-MDI and IEEE 802.3ab-compatible. When a port's speed and duplex mode are set through Auto-Negotiation, the port uses the auto-MDI feature to automatically configure itself as MDI or MDI-X when connected to an endnode. Consequently, you can use either a straight-through or crossover twisted-pair cable when connecting any network device to a port.

System and Port LEDs

The system and port LEDs on the front panel of the AT-FS724L switch display the switch and its port status information. Each port has two LEDs. Table 1 describes the system and twisted-pair port LEDs on the ATFS716L and AT-FS724L Fast Ethernet switches. Table 1. System and Port LEDs LED POWER

L/A

State

Description

Green

The switch is powered ON and operating normally.

OFF

The switch has no power.

Green

The port is establishing a valid link at 100 Mbps.

Blinking Green

The port is receiving/transmitting data at 100 Mbps.

Amber

The port is establishing a valid link at 10 Mbps.

Blinking Amber

The port is receiving/transmitting data at 10 Mbps.

OFF

There is no valid link on the port.

15

Page 16

Chapter 1: Product Description

Table 1. System and Port LEDs LED

DPX

High Efficiency Internal Power Supply

State

Description

Green

The port is establishing at full-duplex mode.

Blinking Green

Collisions are present on the port.

OFF

The port is establishing at half-duplex mode.

The AT-FS716L and AT-FS724L Fast Ethernet Switches are both designed for low power consumption while operating. They use internal, high efficiency, universal switching power supplies operating from 100 ~ 240V AC at 50/60 Hz. The AT-FS716L switch has a maximum power consumption of 4.6 Watts when the LED ecoFriendly switch is ON and all 16 ports are loaded with 100 MB of network traffic on 100m cables. The AT-FS724L switch has a maximum power consumption of 6.7 Watts with the LED ecoFriendly switch ON and all 24 ports loaded with 100 Mbps of network traffic on 100m cables. Note This maximum power consumption information was measured when the switchs’ AC input voltage was 240 VAC @ 50 Hz.

16

Page 17

The text of this page cannot be shown here; see it in the PDF.

Page 18

Chapter 1: Product Description

Duplex Mode

Duplex mode refers to how an end-node receives and transmits data. If an end-node can receive or transmit data, but not both simultaneously, it is operating in a half-duplex mode. If an end-node can receive and transmit data simultaneously, the end-node is said to be operating in full-duplex mode. Naturally, an end-node capable of operating in full-duplex can handle data much faster than an end-node that can only operate in halfduplex mode. The twisted-pair ports on the AT-716L and AT-FS724L Fast Ethernet switches can operate in either half-or full-duplex mode. They are IEEE 802.3u-compliant and use Auto-Negotiation to set the duplex mode setting for you automatically. Note For Auto-Negotiation to operate properly on a switch, the end-nodes connected to the switch should also use Auto-Negotiation. If an endnode does not have this feature and has a fixed duplex mode of fullduplex, the result will be a duplex mode mismatch between the endnode and a switch port. A port on the switch connected to an endnode with a fixed duplex mode of full-duplex will operate at only halfduplex. This results in the end node using full-duplex and the switch port using half-duplex. This can produce network performance problems. Should you encounter this situation, you must configure the port on the end-node to use Auto-Negotiation or, if it lacks that feature, to half-duplex.

Store and Forward

Both switches use store and forward as the method for receiving and transmitting frames. When a Ethernet frame is received on a switch port, the switch does not retransmit the frame out the destination port until it has received the entire frame and stored the frame in a port buffer. Then it examines the frame to determine if it is a valid frame. Invalid frames, such as fragments or runts, are discarded by the switch. This insures that only valid frames are transmitted out the switch ports and that damaged frames are not propagated on your network.

Backpressure and Flow Control

To maintain the orderly movement of data between the end-nodes, an Ethernet switch may periodically need to signal an end-node to stop sending data. This can occur under several circumstances. For example, if two end-nodes are operating at different speeds, the switch, while transferring data between the end-nodes, might need to instruct the faster end-node to stop transmitting data allowing the slower end-node to catch up. An example of this would be when a server operating at 100 Mbps is sending data to a workstation operating at only 10 Mbps.

18

Page 19

AT-FS716L & AT-FS724L Fast Ethernet Switch Installation Guide

How a switch signals an end-node to stop transmitting data differs depending on the duplex mode of the end-node and switch port. A twisted-pair port operating in half-duplex mode stops an end-node from transmitting data by forcing a collision. A collision on an Ethernet network occurs when two end-nodes attempt to transmit data using the same data link at the same time. A collision causes an end-node to stop sending data, wait for a brief period of time, and then retransmit the same data. Once the switch is ready to receive data again, the switch stops forcing collisions. This is referred to as backpressure. A port operating in full-duplex mode uses PAUSE frames, as specified in the IEEE 802.3x standard, to stop the transmission of data from an endnode. Whenever the switch wants an end-node to stop transmitting data, it issues this frame. The frame instructs the end-node to cease transmission for a period of time specified within the frame. The switch continues to issue PAUSE frames until it is ready again to receive data from the endnode. This is referred to as flow control.

19

Page 20

Chapter 1: Product Description

Network Topologies This section illustrates two network topologies that you can create with either the AT-FS716L or the AT-FS724L Fast Ethernet switch in the following sections. Both the power workgroup and cascade topologies are described.

Power Workgroup Topology

The topology shown in Figure 4 is commonly referred to as a power workgroup topology. In this configuration, each workstation, or end-node is connected directly to a port on the switch. Each end-node has a dedicated data link to the switch for best performance and reliability. The devices can operate at either 10 Mbps or 100 Mbps.

AT-FS716L

100 LINK

16 Port Unmanaged Fast Ethernet Switch

1

3

5

7

9

11

13

15

POWER 2

4

6

8

10

12

14

16

ACT

10 LINK

FDX

ACT

HDX

COL

1

3

5

7

9

11

13

2

4

6

8

10

12

14

15

16

1539

10 Mbps 100 Mbps

Figure 4. Power Workgroup Topology

20

Page 21

AT-FS716L & AT-FS724L Fast Ethernet Switch Installation Guide

Cascade Topology

Connecting two similar networking devices together is called “cascading.” Figure 5 illustrates this topology where Port 19 on the AT-FS724L switch is connected to Port 16 on the AT-FS716 switch. Since the ports are configured as auto MDI/MDI-X, a crossover or straight-through Category 5 or better twisted-pair cable can be used in any of the ports.

AT-FS716L

100 LINK

16 Port Unmanaged Fast Ethernet Switch

1

3

5

7

9

11

13

15

POWER 2

4

6

8

10

12

14

16

AT-FS724L 1

3

5

7

9

11

13

15

17

19

21

23

2

4

6

8

10

12

14

16

18

20

22

24

10 LINK

FDX

ACT

HDX

COL

3

5

7

9

11

13

15

2

4

6

8

10

12

14

16

100 LINK

24 Port Unmanaged Fast Ethernet Switch

POWER

ACT

1

ACT

10 LINK

FDX

ACT

HDX

COL

1

3

5

7

9

11

13

15

17

19

21

2

4

6

8

10

12

14

16

18

20

22

23

24

1538

10 Mbps 100 Mbps

Figure 5. Cascade Topology

21