Page 1 of Adtran TA-3000 DS3 MUX Spec Sheet

Spec sheet · Adtran

Adtran TA-3000 DS3 MUX Spec Sheet

Spec sheet2 pagesPDF 1.2 MB

Both pages are below, each with its text.

Download the PDF1.2 MB

Covers · 1 model

The models it covers

From the sheet · read page by page

Key facts from this sheet

Each line names its page in the PDF.

This two-page spec sheet describes the ADTRAN Total Access 3000 DS3 Multiplexer Module, which gives a Total Access 3000 or Total Access 3010 chassis network access over a 45 Mbps DS3 signal. It lists the features, redundancy and timing options, and the mechanical, electrical, environmental and regulatory specifications.

Device
DS3 multiplexer module that terminates a DSX-3 signal and splits it into 21 E1s for a Total Access 3000 or 3010 p. 1
Network interface
45 Mbps DS3, M13 or C-bit parity formats, B3ZS line code p. 1
E1 transport
G.747 E1 encapsulation, so E1s and T1s can be mixed in the same DS3 p. 1
Time slot assignment
Full time slot assignment: any payload E1 can be routed to any slot in the shelf p. 1
Redundancy
Simplex or redundant working/hot-standby setup with 1:1 equipment protection switching p. 1
Timing
Loop timing from the incoming DS3 or the onboard 20ppm clock p. 1
Mounting
Plugs into the multiplexer slot of a Total Access 3000 or Total Access 3010 chassis p. 2
Dimensions
13.2 cm H, 2.5 cm W, 24.6 cm D p. 2
Input power
-48 VDC nominal, -42 VDC minimum, -56 VDC maximum p. 2
Operating temperature
-40°C to +65°C; storage -40°C to +85°C; humidity up to 95 percent, noncondensing p. 2
Faceplate
LEDs for Power, Status, Test, Lockout and On Line; APS and Test/Enable switches p. 2
Software
Upgrades are uploaded from the SCU craft interface p. 1

What this sheet walks you through

  • Features of the DS3 multiplexer module p. 1
  • Mechanical, electrical and environmental specifications p. 2

Good to know

  • Each power bus needs -48 VDC and return, and all metal chassis elements need a frame ground. p. 2

Questions this sheet answers

Which chassis does the Total Access DS3 multiplexer fit?

It plugs into the multiplexer slot of an ADTRAN Total Access 3000 or Total Access 3010 chassis. p. 2

How many E1s does the TA 3000 DS3 MUX carry?

It splits a DS3 into 21 E1s and can route any payload E1 to any slot in the shelf. p. 1

Can two DS3 multiplexers run as a redundant pair?

Yes. Two modules can run as working and hot-standby, and a linked setting provisions the second automatically when the first is changed. p. 1

What temperature range is the TA 3000 DS3 MUX rated for?

It operates from -40°C to +65°C and can be stored from -40°C to +85°C. p. 2

The file

Size and text

Pages2
PDF1.2 MB
TextText from the PDF itself.

Every page · 2

Read it here

Each page as it is printed, and its words beside it, so a phone can search and copy them.

Page 1 of Adtran TA-3000 DS3 MUX Spec Sheet

The text of page 1, from the PDF itself

Global

DS3 Product Description

Product Features

  • Supports M13 or C-bit

parity DS3 formats

  • Supports G.747

E1 encapsulation

  • Full time-slot assignment

(TSA) supported

  • B3ZS line code
  • Detects and indicates

DS3 alarm and loopback conditions

  • Supports local or

loop timing

  • Provides 1:1 equipment

protection switching

  • Extended temperature

(–40°C to +65°C)

  • Provides comprehensive

and easy-to-understand circuit maintenance information

ADTRAN’s Total Access DS3 multiplexer module provides the Total Access 3000 or the Total Access 3010 with high-speed digital network access via a 45Mbps DS3 signal. The DS3 terminates a standard DSX-3 signal from the network and multiplexes/demultiplexes the signal into 21 E1s. It provides full time slot assignment capabilities, allowing any payload E1 in the DS3 data stream to be routed to any slot in the Total Access shelf. The Total Access DS3 multiplexer supports simplex or redundant configurations. It supports redundancy by operating in a working/hot-standby configuration. Optional linked configuration is available from the provisioning screen, so that a second multiplexer can be provisioned automatically when changes are made to the first. If redundancy is not required, the Total Access system will operate reliably with only one DS3 multiplexer installed. The DS3 multiplexer supports industrystandard service states, and each state is selectable using the intuitive and extensive menu structure accessible from the SCU. Timing can occur from the incoming DS3 signal, or the MUX can run on its onboard 20ppm clock. Any upgrades to the software can be uploaded from the SCU craft inter-

face. Full performance monitoring and testing, including loopbacks to the customer and the network, can be accomplished from the menu system. The Total Access hosting the DS3 multiplexer module supports the ANSI G.747 standard for transporting E1s across a DS2. Multiplexing four DS1s or three E1s onto the same channel results in a DS2. By supporting the standard, the DS3 multiplexer can mix E1s and T1s within the same DS3 and interoperate with switches and Digital Cross Connect Systems that support the standard encapsulation. The Total Access 3000 and Total Access 3010, ADTRAN’s Carrier Class Advanced Wideband platforms, are open-architecture platforms for deploying present and future loop technologies in an ultra-dense, versatile, managed package. They can serve as Office Repeater Bays, M13 multiplexers, STS-1 or OC3 SONET multiplexers, or ISDN DLCs. Total Access supports HDSL, HDSL2, HDSL4, T1/E1, ISDN, SHDSL, DSX, and Fiber Optic loop interfaces. It is the industry's only single chassis that can simultaneously support DS3 and DSX-1, or SONET and DSX-1/E1 network interfaces.

DS3 MUX DS3 0-455 ft ADM or Digital Cross Connect

Total Access® 3010

Page 2 of Adtran TA-3000 DS3 MUX Spec Sheet

The text of page 2, from the PDF itself

ADTRAN, Inc. Attention: International Department 901 Explorer Boulevard Huntsville, Alabama 35806 USA

www.adtran.com Asia Pacific - Beijing, China 8610 8857-6415 voice 8610 8857-6417 fax sales.china@adtran.com Asia Pacific - Guangzhou, China 8620 8384-6015 voice 8620 8384 7127 fax sales.china@adtran.com Asia Pacific - Hong Kong, China 852 2824-8283 voice 852 2824-8928 fax sales.asia@adtran.com Asia Pacific - Melbourne, Australia 61 3 9658-0500 voice 61 3 9658-0599 fax sales.australia@adtran.com Canada - Montreal, Quebec 1 877 923-8726 toll free 1 514 940-2890 fax sales.quebec@adtran.com Canada - Toronto, Ontario 1 416 290-0585 voice 1 416 296-1259 fax sales.ontario@adtran.com Canada - Other Provinces 1 877 923-8726 toll free sales.canada@adtran.com Europe/EMEA - Bad Homburg, Germany 49 6172 483-2304 voice 49 6172 483-2305 fax sales.europe@adtran.com Latin America/Caribbean 1 954 474-4424 voice Florida, USA 1 256 963-7551 voice Alabama, USA 1 954 474-1298 fax Florida, USA sales.latin@adtran.com Mexico 1 954-474-4424 voice USA 1 256-963-7551 voice Alabama, USA 1 954-474-1298 fax USA sales.mexico@adtran.com U.S. Headquarters Huntsville, Alabama USA 1 256 963-8669 voice 1 256 963-6300 fax international@adtran.com

DS3 Total Access 3000 DS3 Multiplexer Module

Product Specifications Mechanical

Regulatory Standards

  • Dimensions: 13.2 cm. H, 2.5 cm. W, 24.6 cm. D
  • NEBS Level 3
  • Plugs into an ADTRAN Total Access 3000 or
  • GR-1090-CORE

Total Access 3010 Chassis multiplexer slot

  • UL 1950

Faceplate Features■ IEC 950LEDs

  • CE Mark
  • EN 300-386-2
  • Power
  • Status

Environmental

  • Test
  • Operating Temperature: –40°C to +65°C
  • Lockout
  • Storage Temperature: –40°C to +85°C
  • On Line
  • Relative Humidity: Up to 95 percent, noncondensing

Switches

  • APS (automatic protection switching)

Ordering Information■ Test/EnableElectricalEquipmentPower RequirementDS3 Multiplexer Module

  • –48 VDC and return for each power bus

Part #

  • Frame ground for all metal

chassis elements

Input Power

  • –48 VDC nominal
  • –42 VDC minimum
  • –56 VDC maximum

SNMP Management Station

Basic Rate ISDNISDN Voice SwitchDS3 Ethernet LANVT100 TerminalSTS-1 OC3X.25 NetworkRS-232C 10BaseTNetworkNetwork44 E1Built-in PADTotal Access 3010E1 circuit2 HDSL 4-wire circuitsNetworkHDSL 4-wire circuitsNTU HD-10TDRDB1B2 TESTPWR LINEExpress 3000

ADTRAN Loop Support System

HREG.703 G.703NTU V.35 or G.703

ADTRAN is a TL 9000 registered company.

I61181020L1-8B April 2003 Copyright © 2003 ADTRAN, Inc. All rights reserved.

Specifications subject to change without notice. All registered trademarks and trademarks mentioned in this publication are the property of their respective owners.

G.703SHDSL10 U-interfaces

ADTRAN is a ISO 9001 registered company.

1181020L1

Express 3000 ISDN Terminal Adapter

E1 circuit G.703 NID