For the Accu-Time Series 5000
Page 10
For ETHERNET communication applications, ATS recommends using a CATEGORY 4 or 5 unshielded twisted pair high-speed data transmission cable. One end of the 568B RJ45 terminated cable is plugged into the Series 5000 ETHERNET communication port, while the other end is plugged into the network hub.
Ethernet Communication Port Wand Port T
U
Test/Use Switch Power Port Optional UPS Battery
DI/DO Port
(Sectional Cut-out of the Terminal Chassis)
System Network Cable
Hub POWER SUPPLY
Ethernet Hub 10BASE-T
ACCU-TIME SYSTEMS ELLINGTON, CT
ATS POWER SUPPLY
A B C D E F G H I
J K L M N
VALID
INVALID
O P Q R S T U
ACCU-TIME SYSTEMS ELLINGTON, CT
1 2 3 4 5 6 7 8 9
ATS POWER SUPPLY
A B C D E F G H I
J K L M N
SPACE
SHIFT
0
V W X Y Z
ENTER
7 MANU5000-01(04) 5KENET.DRW
1 2 3 4 5 6 7 8 9
LOW CLEAR
POWER
INVALID
O P Q R S T U
LOW
V W X Y Z
VALID
SPACE
SHIFT
CLEAR POWER
0
ENTER
Page 11
Terminal Face Align the faceplate of the Series 5000 over the base assembly. Plug the data cable into the eight- (8) position communication port of the Series 5000. Attach the output of the 12VDC power pack assembly into the power jack of the Series 5000. Plug the primary of the power pack assembly to the conventional wall outlet. With the terminal’s USE/TEST switch in the USE mode, attach the face to the base assembly. Secure the assemblies with the key lock. The Series 5000 will power-up and display the on-line default message. (Refer to the ATS SETUP MODE section of this manual for terminal communication setup parameters) Attach the remaining end of the data cable into the host computer port. The Series 5000 is now ready for operation.
ATS
R
ACCU-TIME SYSTEMS ELLINGTON, CT
Wand Connector Pin Outs
A B C D E F G H I
J K L M N
VALID
1 2 3 4 5 6
INVALID
O P Q R S T U V W X Y Z
7 8 9 LOW
SPACE
SHIFT
CLEAR POWER
0
ENTER
Pin #
Description
1 2 3 4 5 6
Earth Ground Ground + 5 VDC + 5 VDC Wand Data N/C
(Terminal Face) PIN 1
Modular plug end view
Modular jack inside view wandpo
Battery
(Back Chassis)
8 MANU5000-01(04)
Page 12
ACCU-RATE SET-UP AND DIAGNOSTICS POWER UP To power up the Series 5000 a 12VDC source must be applied to the terminal power jack. The Series 5000, with the TEST/USE switch placed in the USE mode, beeps, executes a power up sequence and displays the message “TERMINAL LOCKED”. ACCESSING TEST MODE To access the test mode: 1) Unlock the base assembly on the Series 5000. 2)
Locate the Test/Use switch on the I/O board assembly.
3)
Slide the switch into the TEST position. The Series 5000 displays “ATS TEST MODE”.
4)
By pressing the CLEAR key, the user can step through the selections. (*NOTE* Test mode may be exited at any time by placing the Test/Use switch back to the USE position and pressing the CLEAR key).
SELECTIONS: •
ATS TEST MODE: Tests the Keypad, Display, Memory, Real Time Clock, Bar Code or Magnetic Slot reader and Bar Code Wand circuitry.
•
ATS SET-UP MODE: Configures the communication parameters - Baud Rate, Parity Bit, Terminal Address, and Terminal Application Type.
•
ATS NETWORK TEST: Performs a terminal to host communication loop-back test. Verifies integrity of cabling.
•
ATS BATTERY TEST: Checks the terminal battery back up option.
•
ATS DI-DO TEST: Checks the Digital Input/Digital Output auxiliary port by performing a loop-back test.
•
ATS RESTART MODE: Resets the terminal, clears all data from memory and performs a power-up sequence.
9 MANU5000-01(04)
Page 13
ATS TEST MODE: ATS TEST MODE checks the functionality of the terminal Keypad, Memory, Real Time Clock, Bar Code or Magnetic Slot reader and Bar Code Wand circuitry. To enter the TEST MODE, press the ENTER key. The message “ATS TEST MODE” appears on the top line of the nd display. The 2 line of the display indicates the two program (EPROM) numbers. By pressing the ENTER key the following information appears: ATS TEST MODE (XXX) (YY) ---------------------The terminal displays ATS TEST MODE on the top line followed by two sets of numbers. The first number (XXX) indicates the amount of memory installed (in Kilobytes). The right most number (YY) indicates the terminals Real Time Clock incrementing in seconds (00-59). Testing the Keypad At this time the user may test the keypad assembly. Each time a key is pressed the terminal will beep and the key nd value will appear on the 2 line of the display. Press the ENTER key. The message “KEY INPUT ACCEPTED” is displayed. Each time the ENTER key is pressed an internal test of the terminal’s communication port is performed. If an error is detected the message “COMM PORT FAIL” will display, the invalid light will flash and the negative acknowledgement beeper tone will cycle. This message will continue until power is removed from the terminal. Testing the Badge Reader ATS TEST MODE accepts inputs from slot readers (optical or magnetic) and bar code wands. To test the reader, simply swipe the applicable bar code or magnetic stripe badge. The terminal beeps and displays the badge data. To test the bar code wand, the user lightly drags the tip of the wand across the bar code badge or label. The wand should be positioned in the hand, similar to that of a pen or pencil, at an approximate 30ο angle. Begin the scanning process by dragging the wand horizontally, in a straight line, and at a constant speed across the entire label area. Each bar code label includes a preceding and trailing ¼ inch quiet zone. This area, which is free of any marks or bars, is a part of the bar code label and must be included when scanning the label. Upon the successful completion of a bar code read the terminal will beep and display the data. To proceed to the ATS SETUP MODE press the CLEAR key.
ATS SETUP MODE ATS SETUP MODE allows the operator to configure the terminal for communications with the host computer. The Series 5000 default parameters are set as follows: Baud Rate Parity Address Terminal Application Type
9600 ODD 01 A
To enter the ATS SETUP MODE, press the ENTER key at the “ATS SETUP MODE” display prompt. (Prior to nd pressing the ENTER key, the 2 line of the display will indicate the current terminal setup values.)
10 MANU5000-01(04)
Page 14
Baud Rate To change the terminal baud rate: 1.
Press the CLEAR key to step through the baud rate choices: 19200 9600 4800 2400 1200 M1200 (modem) M2400 (modem)
2.
When the desired baud rate is displayed, press the ENTER key to store the value and advance to the next parameter.
3.
If a modem baud rate is selected, a self-test will be performed on the modem. The results of this test will be displayed. The operator will be prompted to enter the number of auto answer rings. NOTE: If no modem is installed and a modem baud rate has been selected, the modem self test will fail.
Parity To change the parity: 1.
Press the CLEAR key to step through the parity choices: ODD EVEN NONE
2.
When the desired parity is displayed, press the ENTER key to store the value and advance to the next parameter.
Address To change the terminal address: 1.
Press the CLEAR key to increment the address values from 01 to 32.
2.
When the desired address is displayed, press the ENTER key to store the value and advance to the next parameter.
Terminal Application Type The Terminal Application Type is used as a delimiter by the host for routing application information to the terminal. (Example-an access control terminal could have a different terminal type than a time and attendance terminal) To change the terminal application type: 1.
Press the CLEAR key to increment the type from A to J.
2.
When the desired type is displayed, press the ENTER key to store the value and advance to the ATS NETWORK TEST. 11
MANU5000-01(04)
Page 15
ATS NETWORK TEST ATS NETWORK TEST is a two-part test. The first allows the network wiring between the terminal and the host to be checked for open connections or wiring errors. This test requires that the ATS RS232 Communication Adapter which is plugged into the host, be unplugged and pins 2 & 3 of the adapter jumped together (a paper clip should do the trick). Secondly, a local test can be performed on the terminal communication circuitry. This test will work for both RS232 and RS485 installations (RS485 installations require an ATS 232/485 Converter). To enter NETWORK TEST, press the ENTER key at the “ATS NETWORK TEST” prompt. The following message appears: SWITCH TEST SWITCH TO USE POSITON Place the switch on the back of the terminal into the USE position. The Series 5000 performs a network test in which the terminal sends data up to the host, via the network cabling. Since a temporary jumper was installed in the ATS RS232 Communication Adapter, the data will be looped back to the terminal. The following message should appear: NETWORK TEST PASS ENTER TO RETEST To perform the local communication loop back, place the USE/TEST switch back to the TEST position and press the ENTER key. The following message should appear: NETWORK TEST PASS ENTER TO RETEST Remove the jumper from the RS232 Communication Adapter and secure it back into the host port. Press the CLEAR key to advance to the next test.
ATS BATTERY TEST The ATS BATTERY TEST checks the terminal battery backup option if installed. To enter this test, press the ENTER key at the “ATS BATTERY TEST” prompt. The following message should appear: BATTERY TEST PASS ENTER TO RETEST Note: If the battery backup option is not installed, the battery test will fail. Press the CLEAR key to advance to the ATS DI-DO Test.
ATS DI-DO TEST The ATS DI-DO Test is a two-part test that checks the terminal auxiliary DATA IN/DATA OUT port connection by performing a loop back communication test on the port circuitry. To enter the ATS DI-DO Test: 1.
Press the ENTER key at the “ATS DI-DO TEST” prompt. The following message should appear: SWITCH TEST SWITCH TO USE POSITION
2.
Place the test switch into the USE position. Since no loop back jumper is installed during this phase of 12
MANU5000-01(04)
Page 16
testing the following message will appear: DI-DO TESTING DI-DO TEST FAILED ENTER TO RETEST 3.
Place the TEST/USE switch into the TEST position. This will provide the terminal with its own loop back jumper.
4.
Press the ENTER key. The following message should appear: DI-DO TEST PASSED ENTER TO RETEST
5.
Press the CLEAR key to advance to ATS RESTART MODE.
ATS RESTART MODE The ATS RESTART MODE clears all transaction data and any download from memory. To restart the terminal: 1.
Press the ENTER key to select the ATS RESTART MODE. The terminal displays: PRESS ENTER TO CLEAR ALL TRANSACTION DATA
2.
Press the ENTER key. The terminal displays: CLEAR FOR CYCLE TEST (Note: Cycle test is for factory diagnostics only) ENTER FOR RESTART
3.
Press the ENTER key. The terminal displays: CLEARING MEMORY. . . The green Valid LED will blink and the terminal will execute its power up sequence and return to the beginning of the Test Mode.
4.
To exit the Test Mode, place the TEST/USE switch to the USE position and press the CLEAR key. The terminal will execute its power up sequence. The terminal displays: “TERMINAL LOCKED” and can now accept a host download.
This completes the ACCU-RATE test and set-up
13 MANU5000-01(04)
Page 17
ACCU-RATE ETHERNET SET-UP AND DIAGNOSTICS ATS TEST MODE checks the ETHERNET circuitry installed in the Time and Data Collection Terminals. To accurately test this circuit the following sequential steps should be adhered to. NOTE: The Ethernet communication cable must be connected to the Time and Data Collection Terminal with running Host software for this operation to be successful. With the “TEST MODE” message in the terminal display, press the CLEAR key five (5) times. The message “ATS RESTART MODE” appears on the top line of the display. Press the ENTER key three (3) times to clear all memory prior to testing the ETHERNET circuit. (Omitting this step greatly increases the chances of unreliable test results in the ETHERNET circuit). After resetting, the terminal will again display “TEST MODE”. Press the CLEAR key one (1) time. The message “ATS SETUP MODE” 000.000.000.000 displayed for one (1) second Followed by: TERM 000.000.000.000 displayed for one (1) second Followed by: HOST 000.000.000.000 displayed for one (1) second Followed by: GATE (This message will only appear if the gate address was previously loaded.) Followed by: MASK 000.000.000.000 displayed for one (1) second Followed by: BROADCAST ENABLED or DISABLED displayed for one (1) second Followed by: APP ACK ENABLED or DISABLED displayed for one (1) second Followed by: WATCHDOG ENABLED or DISABLED displayed for one (1) second The above sequence will repeat itself until either the CLEAR or ENTER key is pressed. Pressing the CLEAR key will bypass the test. Pressing the ENTER key will enable the test. Press the ENTER key. The following message will be displayed: TERMINAL IP ADDRESS
###. ###. ###. ###. _ _ _
This is the Time and Data Collection unit’s unique Internet Protocol address. (See your network administrator for assignment.) Enter, via the terminal’s keypad assembly, the numeric IP Terminal address in blocks of three followed by the ENTER key. Once all four octets are entered the following message will be displayed: HOST IP ADDRESS
###. ###. ###. ###. _ _ _
This is the Host’s unique Internet Protocol address. (See your network administrator for assignment.) Enter the numeric IP Host address in blocks of three followed by the ENTER key. Once all four blocks are entered the following message will be displayed: NETWORK MASK
###. ###. ###. ###. _ _ _
This is the Subnet Mask used for channeling. (See your network administrator for assignment). Enter the numeric Mask address in blocks of three followed by the ENTER key. Once all four blocks are entered the following message will be displayed: HIT ENTER IF DEFAULT ROUTE REQUIRED
14 MANU5000-01(04)
Page 18
If a Router or Gateway is required press the ENTER key. The following message will be displayed: ROUTER IP ADDRESS ###. ###. ###. ###. _ _ _ This is the system Router used for directing Internet traffic among a variety of Hosts. (See your network administrator for assignment.) Enter the numeric Router or Gateway address in blocks of three followed by the ENTER key. The next message allows an enablement of the Broadcast Receive command. If this function is disabled, the terminal will ignore all broadcast packets. HIT ENTER TO ENABLE BROADCAST RECEIVE Disabling Broadcast Receive may be accomplished by pressing the CLEAR key (recommended for networks with heavy traffic). Upon disablement, only devices connected to the same IP address will be able to “Ping” terminals. The Application Acknowledgement message assures that the Host has received the last transaction, which enhances data integrity by affirming that the transaction has not been held up in a router/gateway or lost. The terminal will display the following: HIT ENTER TO ENABLE APPLICATION ACK Application Acknowledgement may be disabled by pressing the CLEAR key. The next message, TCP/IP Watchdog, provides a “soft restart” if the connected terminal has not communicated with the Host for approximately ten- (10) minutes. The terminal will display the following message: HIT ENTER TO ENABLE TCP/IP WATCHDOG Pressing the CLEAR key will disable TCP/IP Watchdog. The following message allows the Ethernet communication connection. ENETADD=XXXXXXXXXXXXHIT ENTER TO CONNECT The XXXXXXXXXXXX represents the unique Ethernet address programmed into the EPROM by the factory. If a Router is not required Press the CLEAR key. The following message will be displayed: ENETADD=XXXXXXXXXXXXHIT ENTER TO CONNECT The XXXXXXXXXXXX represents the unique Ethernet address programmed into the EPROM by the factory. Press the ENTER key or the CLEAR key if connection is not required. The terminal will briefly display an initializing message followed by: CONNECTING TO SERVER If the connection to the server was successful the following message is displayed: CONNECTION COMPLETE If the connection to the server was not successful the following message is displayed: CONNECTION FAILED!! HIT ENTER TO CONNECT
15 MANU5000-01(04)